Catalogo Electrodos Ise

HANNA Instruments
View more...
   EMBED

Share

  • Rating

  • Date

    December 1969
  • Size

    849.5KB
  • Views

    1,339
  • Categories

Preview only show first 6 pages with water mark for full document please download

Transcript

Electrodes | Solutions | Instrumentation ION SELECTIVE MEASUREMENT catalog featuring our full line of Ion Selective Electrodes Introduction HANNA instruments, Inc. Woonsocket, RI USA Dear Valued Customer, It is with great pleasure that I introduce HANNA’s new line of Ion Selective Electrodes. These electrodes complement our extensive offering of high performance electrochemical products. This catalog features our complete line of half-cell and combination Ion Selective Electrodes as well as meters and accessories to complete this new line. ISE technology offers considerable advantages to analytical chemistry. These electrodes are ideal in a wide range of industries such as research laboratories, agriculture, education, food processing, biomedical, metal finishing, waste treatment, power generation and water quality monitoring. Our new Ion Selective line is fully supported with ionic strength adjusters, filling solutions and certified standards. Each electrode has been developed, produced and rigorously tested to confirm high performance, durability and HANNA instruments® is an ISO 9001:2000 Certified company. quick response in our state-of-the-art ISO 9001:2000 U.S. production facility. Thank you for making HANNA instruments® a continuing success for the past 30 years. Martino Nardo President 2 ION SELECTIVE MEASUREMENT HANNA instruments ® Table of Contents Table of Contents Overview ISE Electrode Types . . . . . . . . . . . . . . . . . . . . .4 Reference and Combination Electrodes . . . . . . . . . .5 ISE Electrodes Ammonia Bromide Cadmium . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6 Calcium Carbon Dioxide Chloride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 Cupric Cyanide Fluoride . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 Iodide Lead/Sulfate Nitrate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 Potassium Silver/Sulfide Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 Sensors and Accessories Reference Chart . . . . . . . . . . . . . . . . . . . . . . .11 Solutions ISE Standards Gas Sensor Fill Solutions Specific Solutions for ISE Sensors . . . . . .12 Ionic Strength Adjusters Silver-free Reference Fill Solutions Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . .13 Measurement Direct Potentiometry Portable ISE Meters . . . . . . . . . . . . . . .14-15 Incremental Methods pH/ISE Bench Meter . . . . . . . . . . . . . . .16-17 Potentiometric Titrations Automatic Titrators . . . . . . . . . . . . . . .18-19 HANNA instruments ® ION SELECTIVE MEASUREMENT 3 Overview ISE Electrode Types ion selective electrodes can be grouped into three general categories based upon construction. Solid State Electrodes are available as both single half-cells or as combination electrodes complete with reference electrode. These electrodes incorporate a solid sensing surface made of compressed silver halides, or solid crystalline material. HANNA’s offering includes sensors for the determination of bromide, cadmium, chloride, cupric, cyanide, fluoride, lead and silver ions. Solid body construction is rugged for long life. Theory: A solid state electrode develops a voltage due to ion-exchange occurring between the sample and the inorganic membrane. An equilibrium mechanism occurs due to the very limited solubility of the membrane material in the sample. 4 ION SELECTIVE MEASUREMENT Liquid Membrane Electrodes are available as single half-cells or as combination electrodes complete with reference electrode. The sensing surfaces of these electrodes are comprised of a homogeneous polymer matrix containing organic ion-exchangers selective for the determined ion. These sensors incorporate easily replaceable membrane modules and are available for measurements of nitrate, potassium and calcium. Theory: The potassium electrode was one of the earliest liquid membrane sensors developed of this type. The membrane is usually in the form of a thin disc of PVC impregnated with the antibiotic valinomycin. The exchanger, also known an ionophore, is a ring structure that fits potassium ions inside like a lock and key. This type of membrane is not as rugged as the solid state type so they are designed for easy replacement of the sensing module. Ga s Liq uid Sol id S tat e HANNA’s Gas Sensors are combination electrodes that detect dissolved gases in a solution. No external reference is required for these electrodes. The sensing element is separated from the sample solution by a gas permeable membrane. HANNA’s offering includes the HI 4101 Ammonia electrode and the HI 4105 Carbon Dioxide electrode. Theory: A gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film is the same. The pH change is proportional to the dissolved gas in the sample. HANNA instruments ® Overview Reference and Combination Electrodes HANNA’s Co mb ina tio n Ref ere n ce reference electrode is used with our half-cell ISE sensors to provide accurate and repeatable measurements. HANNAs combination electrodes incorporate the measuring electrode with the reference making them ideal for field measurements. Reference Electrodes are used to Combination Electrodes include provide a stable voltage and electrolytic contact to permit a voltage gradient to be measured across a measurement membrane such as an ISE. HANNA has designed an easy to use, unbreakable plastic, double junction, quick fill, sleeve style reference electrode with a cone style junction to work with the ion selective electrode family of sensors. The design forms the liquid junction with the test solution at the tip of the junction cone and not further up the cone surface. The design produces a highly stable reference electrode with reasonable low flow rates. The model HI 5315 is a silver/silver chloride electrode half-cell with a permanent gel filled internal cell. The outer fill solution is easily replaceable and serves as a buffer zone between the internal chloride ion containing gel and the sample solution. HANNA offers a complete line of silver-free fill solutions to optimize your ion measurement. A fast responding liquid junction, excellent reproducibility, and ease of use will mark this reference as your “best” in the lab. a sensor and reference electrode in a single electrode body. Our combination ion selective electrodes provide the same selectivity and response as our ISE half-cells, but include our superior double junction reference into the same electrode body. Combination solid state electrodes have a built in solid state sensor and quick refillable reference electrode. Our liquid membrane and fluoride combination electrodes have replaceable module construction and the HANNA double junction reference stability. HANNA instruments ® Three Methods of Analysis Potentiometric ion analyses with ISEs are performed by use of one of three methods, each entailing its own advantages: Direct Potentiometry, Incremental Methods, and Potentiometric Titration. HANNA offers a solution for each of these methods, for more details please refer to pages 14-19. ION SELECTIVE MEASUREMENT 5 ISE Electrodes Ammonia • Bromide • Cadmium 120 mm 120 mm 12 mm PARAMETER Code Type Measurement Range AMMONIA 12 mm 12 mm 12 mm BROMIDE CADMIUM HI 4101 HI 4002 HI 4102 HI 4003 HI 4103 Gas-Sensing; Combination Solid-state; Half-cell Solid-state; Combination Solid-state; Half-cell Solid-state; Combination 1M to 1X 10-6M 17000 to 0.02 ppm 1M to 1X 10-6M 79910 to 0.08 ppm 1M to 1X 10-6M 79910 to 0.08 ppm 1M to 1X 10-7M 11200 to 0.01 ppm 1M to 1X 10-7M 11200 to 0.01 ppm Optimum pH Range >11 2 to 12.5 2 to 12.5 2 to 12.5 2 to 12.5 Temperature Range 0 to 40°C 0 to 80°C 0 to 80°C 0 to 80°C 0 to 80°C Approximate Slope -56 -56 -56 +28 +28 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm Delrin Epoxy PEI Epoxy PEI 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial BNC BNC BNC BNC BNC Body Material Cable Connector Possible Applications 6 12 mm 120 mm 120 mm 120 mm Determination of ammonium, ammonia in wine, beer, water, waste water and soil ION SELECTIVE MEASUREMENT Determination of free bromide ions in emulsified food products, beverages, plants, soils and as an indicator for titration Used as an indicator for titrations using chelates HANNA instruments ® ISE Electrodes Calcium • Carbon Dioxide • Chloride 120 mm 120 mm 12 mm PARAMETER 12 mm CALCIUM Code 120 mm 12 mm 120 mm 12 mm CARBON DIOXIDE 120 mm 12 mm CHLORIDE HI 4004 HI 4104 HI 4105 HI 4007 HI 4107 Type Polymer Membrane; Half-cell Polymer Membrane; Combination Gas Sensing; Combination Solid-state; Half-cell Solid-state; Combination Measurement Range 1M to 3X 10-6M 40080 to 0.12 ppm 1M to 3X 10-6M 40080 to 0.12 ppm 1X 10-2M to 1X 10-4M 440 to 4.4 ppm 1M to 5X 10-5M 35000 to 1.8 ppm 1M to 5X 10-5M 35000 to 1.8 ppm Optimum pH Range 4 to 10 4 to 10 4.2 to 5.2 2 to 11 2 to 11 Temperature Range 0 to 40°C 0 to 40°C 0 to 40°C 0 to 80°C 0 to 80°C Approximate Slope +28 +28 +54 -57 -57 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm PVC PEI/PVC Delrin Epoxy PEI 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial BNC BNC BNC BNC BNC Body Material Cable Connector Determination of free calcium in beverages, water, and seawater Possible Applications HANNA instruments ® Determination of carbonates as CO2 in water, soft drinks and wine samples Determination of free chloride ions in emulsified food products, beverages, plants, soils and as an indicator for titration ION SELECTIVE MEASUREMENT 7 ISE Electrodes Cupric • Cyanide • Fluoride 120 mm 12 mm PARAMETER 12 mm 12 mm CUPRIC 120 mm 120 mm 12 mm 12 mm CYANIDE FLUORIDE Code HI 4008 HI 4108 HI 4009 HI 4109 HI 4010 HI 4110 Type Solid-state; Half-cell Solid-state; Combination Solid-state; Half-cell Solid-state; Combination Solid-state; Half-cell Solid-state; Combination 0.1M to 1X 10-6M 6354 to 0.06 ppm 0.1M to 1X 10-6M 6354 to 0.06 ppm 10-2M to 1X 10-6M 260 to 0.02 ppm 10-2M to 1X 10-6M 260 to 0.02 ppm 1M to 1X 10-6M Sat. to 0.02 ppm 1M to 1X 10-6M Sat. to 0.02 ppm Measurement Range Optimum pH Range 2 to 12.5 2 to 12.5 >11 >11 5 to 8 5 to 8 Temperature Range 0 to 80°C 0 to 80°C 0 to 80°C 0 to 80°C 0 to 80°C 0 to 80°C Approximate Slope 26 26 -57 -57 -56 -56 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm 120 mm Epoxy PEI Epoxy PEI Epoxy PEI/Epoxy 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial BNC BNC BNC BNC BNC BNC Body Material Cable Connector Possible Applications 8 12 mm 120 mm 120 mm 120 mm Used as an indicator for titrations using chelates ION SELECTIVE ELECTRODES Determination of free cyanide ions in plating baths, waste water and in plant and soil samples Determination of free fluoride in potable water, soft drinks, wine, plants, emulsified food products, plating and pickling acids HANNA instruments ® ISE Electrodes Iodide • Lead/Sulfate • Nitrate 120 mm 120 mm 12 mm PARAMETER 12 mm 120 mm 12 mm IODIDE 120 mm 12 mm 120 mm 120 mm 12 mm LEAD/SULFATE 12 mm NITRATE Code HI 4011 HI 4111 HI 4012 HI 4112 HI 4013 HI 4113 Type Solid-state; Half-cell Solid-state; Combination Solid-state; Half-cell Solid-state; Combination Polymer Membrane; Half-cell Polymer Membrane; Combination 1M to 1X 10-7M 127000 to 0.01 ppm 1M to 1X 10-7M 127000 to 0.01 ppm 0.1M to 1X 10-6M 20700 to 0.21 ppm 0.1M to 1X 10-6M 20700 to 0.21 ppm 1.0M to 1X 10-5M 6200 to .62 ppm 1.0M to 1X 10-5M 6200 to .62 ppm Measurement Range Optimum pH Range 2 to 13 2 to 13 4 to 7 4 to 7 3.0 to 8 3.0 to 8 Temperature Range 0 to 80°C 0 to 80°C 0 to 80°C 0 to 80°C 0 to 40°C 0 to 40°C Approximate Slope -56 -56 +25 +25 -56 -56 Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm 120 mm Epoxy PEI Epoxy PEI PVC PEI/PVC 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial BNC BNC BNC BNC BNC BNC Body Material Cable Connector Possible Applications Determination of free iodide ions in emulsified food samples (iodized table salt), plants and for titration HANNA instruments ® Determination of lead ions in plating baths and as an indicator for titrations Determination of free nitrate in natural waters (fresh and sea), and in emulsified food and plant samples ION SELECTIVE MEASUREMENT 9 ISE Electrodes Potassium • Silver/Sulfide • Reference 120 mm 120 mm 12 mm 12 mm PARAMETER Code 12 mm POTASSIUM 120 mm 120 mm 12 mm 12 mm SILVER/SULFIDE REFERENCE HI 4014 HI 4114 HI 4015 HI 4115 HI 5315 Type Polymer Membrane; Half-cell Polymer Membrane; Combination Solid-state; Half-cell Solid-state; Combination N/A Measurement Range 1M to 1X 10-6M 39100 to .039 ppm 1M to 1X 10-6M 39100 to .039 ppm Ag+ 1.0M to 1X 10-6M 107900 to 0.11ppm S= 1.0M to 1X 10-7M 32100 to 0.003 ppm Ag+ 1.0M to 1X 10-6M 107900 to 0.11ppm S= 1.0M to 1X 10-7M 32100 to 0.003 ppm N/A Optimum pH Range 1.5 to 12.0 1.5 to 12.0 Ag+ 2 to 8 S= 12 to 14 Ag+ 2 to 8 S= 12 to 14 N/A Temperature Range 0 to 40°C 0 to 40°C 0 to 80°C 0 to 80°C 0 to 80°C Approximate Slope +56 +56 +56 Ag+ / -28 S= +56 Ag+ / -28 S= N/A Body O.D. 12 mm 12 mm 12 mm 12 mm 12 mm Insertion Length 120 mm 120 mm 120 mm 120 mm 120 mm PVC PEI/PVC Epoxy PEI PEI 1m coaxial 1m coaxial 1m coaxial 1m coaxial 1m coaxial BNC BNC BNC BNC Banana Body Material Cable Connector Possible Applications 10 120 mm Determination of potassium ions in wine, waters, soils and biological samples. ION SELECTIVE MEASUREMENT As an indicator for titrations using silver nitrate. For the determination of sulfide ions in waters, paper liquors, natural waters and soils. To complete the electrical circuit and to provide a stable reference voltage for ISE half-cells HANNA instruments ® Reference Chart Sensors and Accessories Reference Chart Electrode Halfcell Type Combination ISA Filling Standard Standard 1 Solution 2 HI 4001-03 1000 ppm Other HI 4000-52 replacement cap HI 4001-51 membrane kit HI 4000-51 replacement pH internal and cap for Ammonia HI 4001-45 conditioning solution HI 4000-47 4 and 7 pH with salt Ammonia Gas — HI 4101 HI 4001-00 HI 4001-40 HI 4001-01 0.1 M Bromide Solid HI 4002 HI 4102 HI 4000-00 HI 7072 HI 4002-01 0.1 M HI 4000-70 polishing strip Cadmium Solid HI 4003 HI 4103 HI 4000-00 HI 7072 HI 4003-01 0.1 M HI 4000-70 polishing strip Polymer membrane HI 4004 HI 4104 HI 4004-00 HI 7082 HI 4004-01 0.1 M HI 4004-51 module HI 4104-51 module for combination HI 4004-45 Conditioning Solution HI 4005-03 1000 ppm HI 4000-54 replacement pH internal & cap for CO2 HI 4005-53 CO2 membrane kit (3 pack) HI 4000-47 4 and 7 pH with salt HI 4005-45 Conditioning Solution HI 4007-03 1000 ppm HI 4000-70 polishing strip Calcium HI 4001-02 100 ppm Standard 3 Carbon Dioxide Gas — HI 4105 HI 4005-00 HI 4005-40 HI 4005-01 0.1 M Chloride Solid HI 4007 HI 4107 HI 4000-00 HI 7072 HI 4007-01 0.1 M Cupric Solid HI 4008 HI 4108 HI 4000-00 HI 7072 HI 4008-01 0.1 M Cyanide Solid HI 4009 HI 4109 HI 4001-00 HI 7072 HI 7075 HI 4010-01 0.1M HI 7072 HI 4011-01 0.1 M HI 4000-70 polishing strip HI 4000-70 polishing strip Fluoride Solid HI 4010 HI 4110 HI 4010-00 HI 4010-05 HI 4010-06 HI 4010-30 Iodide Solid HI 4011 HI 4111 HI 4000-00 HI 4007-02 100 ppm HI 4000-70 polishing strip HI 4000-70 polishing strip HI 4010-02 100 ppm HI 4010-03 1000 pm HI 4010-11 1 ppm with TISAB II HI 4010-12 2 ppm with TISAB II HI 4010-10 10 ppm with TISAB II HI 4110-51 module for combination HI 4010-30 Fluoride measurement kit Solid HI 4012 HI 4112 HI 4012-00 HI 7072 HI 4012-01 Lead HI 4012-21 Sulfate 0.1 M Nitrate Polymer membrane HI 4013 HI 4113 HI 4013-00 HI 7078 HI 4013-01 0.1 M Potassium Polymer membrane HI 4014 HI 4114 HI 4014-00 HI 7076 HI 4014-01 0.1 M HI 4014-51 module HI 4114-51 module for combination Solid HI 4015 HI 4115 HI 4000-00 (Ag+) HI 4015-00 (S=) HI 7072 HI 4015-01 0.1 M Silver HI 4000-70 polishing strip Lead/Sulfate Silver/Sulfide Reference — HI 5315 HANNA instruments ® HI 4013-02 100 ppm HI 4013-03 1000 ppm HI 4013-53 module (3 pack) HI 4113-53 module for combination (3 pack) HI 4013-06 Interferent suppressent ISA HI 7072 HI 7075 HI 7076 HI 7082 HI 7078 ION SELECTIVE MEASUREMENT 11 Solutions HANNA ISE Standards Our wide selection of HANNA ISE Standards are made and bottled in our state-of-the-art solutions facility. ISE Standards are required for direct and incremental measurement techniques and are available with Certificate of Analysis. Code HI 4001-01 HI 4001-02 HI 4001-03 HI 4002-01 HI 4003-01 HI 4004-01 HI 4005-01 HI 4005-03 HI 4007-01 HI 4007-02 HI 4007-03 HI 4008-01 HI 4010-01 HI 4010-02 HI 4010-03 HI 4010-10 HI 4010-11 HI 4010-12 HI 4010-30 HI 4011-01 HI 4012-01 HI 4012-21 HI 4013-01 HI 4013-02 HI 4013-03 HI 4014-01 HI 4015-01 12 Description 0.1 M ammonia std. 100 ppm ammonia std. (as N) 1000 ppm ammonia std. (as N) 0.1 M bromide std. 0.1 M cadmium std. 0.1 M calcium std. 0.1 M carbon dioxide std. 1000 ppm carbon dioxide std. (as CaCO3) 0.1 M chloride std. 100 ppm chloride std. 1000 ppm chloride std. 0.1 M cupric std. 0.1 M fluoride std. 100 ppm fluoride std. 1000 ppm fluoride std. 10 ppm fluoride std. premixed with TISAB II 1 ppm fluoride std. premixed with TISAB II 2 ppm fluoride std. premixed with TISAB II (4) 1 and (4) 10 ppm with (4) TISAB II 0.1 M iodide std. 0.1 M lead std. 0.1 M sulfate std. 0.1 M nitrate std. 100 ppm nitrate std. 1000 ppm nitrate std. 0.1 M potassium std. 0.1 M silver std. ION SELECTIVE MEASUREMENT Size 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL 500 mL HANNA Gas Sensor Fill Solutions Code HI 4001-40 HI 4005-40 Description Ammonia filling solution Carbon dioxide filling solution Size (4) 30 mL bottles (4) 30 mL bottles Specific "Solutions" for ISE Sensors Code HI 4000-47 HI 4001-45 HI 4004-45 HI 4005-45 Description 4 and 7 buffer with chloride background Used to check glass internal of gas sensors Conditioning solution for HI 4101 Conditioning solution for calcium electrodes Conditioning solution for HI 4105 Size 10 packages each to reconstitute + 2 beakers 500 mL 500 mL 500 mL HANNA instruments ® Solutions HANNA Ionic Strength Adjusters (ISA) are formulated to provide a constant ionic strength in sample and standards alike thus permitting concentration rather than activity measurements to be made. In some cases ISA's adjust pH and eliminate matrix effects. Code HI 4000-00 HI 4001-00 HI 4004-00 HI 4005-00 HI 4010-00 HI 4010-05 HI 4010-06 HI 4012-00 HI 4013-00 HI 4013-06 HI 4014-00 HI 4015-00 Description ISA for halide electrodes Alkaline ISA for ammonia/cyanide Calcium ISA Carbon dioxide ISA TISAB II (for fluoride) TISAB II gallon (for fluoride) TISAB III concentrate (for fluoride) Lead or sulfate ISA Nitrate ISA Nitrate interferent suppressent ISA Potassium ISA SAOB (sulfide antioxidant buffer) Size 500 mL 500 mL 500 mL 500 mL 500 mL 1 gallon 500 mL 500 mL 500 mL 500 mL 500 mL 500 ml, 1pkg (2 components) HANNA Accessories HANNA replacement parts and accessories keep your measurements fast and accurate. Code HI 4000-50 HI 4000-51 HI 4000-52 HI 4000-54 HI 4000-70 HI 4001-51 HI 4004-51 HI 4104-51 HI 4005-53 HI 4110-51 HI 4013-53 HI 4113-53 HI 4014-51 HI 4114-51 HI 740155P HI 740159 Description Liquid membrane sensor handle Gas sensor replacement pH for Ammonia Sensor Gas sensor membrane cap for Ammonia Gas sensor replacement pH for Carbon Dioxide Sensor Halide polishing strip Ammonia membrane kit (20 loose) Calcium module for half-cell Calcium module for combination Carbon dioxide membrane kit (3 caps) Fluoride module for combination electrode Nitrate module 3 pack for half-cell Nitrate module 3 pack for combination Potassium module for half-cell Potassium module for combination Capillary pipettes (20 pcs) Plastic tweezers (1 pcs) HANNA Silver-free Reference Fill Solutions Recommended for our Combination ISE Electrodes and the HANNA HI 5315 reference electrode. Reference electrolytes should be topped off daily with the correct filling solution for optimum measurement performance. These solutions are silver free to eliminate silver preciptates found with standard electolytes. Code HI 7072 HI 7075 HI 7076 HI 7078 HI 7082 Description Electrolyte solution, 1 M KNO3 Electrolyte solution with KNO3 and KCl Electrolyte solution, 1 M NaCl Electrolyte solution, (NH4)2SO4 Electrolyte solution, 3.5 M KCl HANNA instruments ® Size (4) 30 mLl bottles (4) 30 mL bottles (4) 30 mL bottles (4) 30 mL bottles (4) 30 mL bottles ION SELECTIVE MEASUREMENT 13 Measurement: Direct Potentiometry HI 98184 • HI 98185 Portable ISE Meters Direct Potentiometry is a widely used method of performing ion analysis with ISEs. This method is highly effective when the user must quickly measure large batches of samples at many concentrations. Our direct reading meters such as the HI 98184 and HI 98185 display concentration of the unknown sample by a direct reading after calibrating the instrument with 2 or more standards. Ionic strength adjustments are made to both samples and standards. In some applications quick and reliable measurements can be made on-site without taking samples back to the laboratory. Instrument Features • Waterproof protection • Direct ISE reading and calibration in ppm • Exclusive Calibration Check™ • Measure pH, ORP or ISE • Inductive battery recharging 14 ION SELECTIVE MEASUREMENT • 5 point calibration • Log on demand (up to 300 records) • Relative mV (for ORP) • Graphic LCD Display with backlighting • ºC or ºF unit selection • Battery charge indication • USB connectivity • Contextual help • Menu driven HANNA instruments ® Measurement: Direct Potentiometry More Features pH electrode, pH solutions, carrying case, batteries and inductive recharger included SPECIFICATIONS HI 98184 pH HI 98185 -2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH mV ±2000 mV Range -3 ISE -20.0 to 120.0 °C (-4.0 to 248.0°F) pH 0.1; 0.01; 0.001 pH mV 0.1 mV ISE 3 digits 0.01; 0.1; 1; 10 concentration Temperature Accuracy 0.1°C (0.1°F) pH ±0.01; ±0.002 pH mV ±0.2 mV ISE ±0.5% of reading (monovalent ions), ±1% of reading (divalent ions) Temperature ±0.4°C (±0.8°F) (excluding probe error) Up to 5 point calibration, 7 standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 custom buffers pH Calibration From 1.00 x 10-7 to 9.99 x 1010 concentration (choice of units) 5 From 1.00 x 10 to 1.00 x 10 ppm Temperature Resolution Measurement Screen Direct ISE readings shown in a choice of units (HI 98185). LCD also displays electrode type used, current temperature, remaining battery life, and time simultaneously. Soft keys allow quick access to the most used functions. Up to 2 point calibration, 6 standard solutions (0.1, 1, 10, 100, 1000, 10000 ppm) ISE Slope Setup Screen HI 98185 allows direct choice of probe type and measurement unit while the HI 98184 requires manual setting of sensor parameters. Up to 5 point calibration, 6 standard solutions (choice of units) From 80 to 110% Temperature Compensation (pH) Manual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F) Probes HI 72911B pH w/BNC and temperature combined Logging Log-on-demand 300 samples (100 each range) PC Connectivity Opto-isolated USB (with HI 92000 software) Input Impedance 1012 Ohms Battery Type/Life (4) 1.2V AA rechargeable batteries/ approx. 200 hrs continuous use (with backlight off ) Recharger Inductive recharger (included) Auto-off User Selectable: 5, 10, 30, 60 min or can be disabled Environment IP67 Dimensions/Weight ISE Calibration Up to 5 point calibration with 6 standard solutions between 0.1 to 10000 ppm. Users are guided through the calibration procedure with step-by-step on-screen instructions. 226.5 x 95 x 52 mm (8.9 x 3.75 x 2”)/525 g (18.5 oz.) ORDERING INFORMATION HI 98184-01 (115V), HI 98184-02 (230V), HI 98185-01 (115V) and HI 98185-02 (230V) are supplied with HI 72911B combined pH/temperature electrode, pH 4.01 and pH 7.01 buffer solutions, 1.2V AA 1300 mAh rechargeable batteries (4), HI 710042 inductive battery charger with power adapter, rugged carrying case and instructions. Rechargeable batteries with inductive recharger These models have up to 200 hour extended battery life to guarantee long operation in the field. When the batteries are low simply leave the meter on the recharger for a few hours and you’re ready to go. The recharger can either be plugged to a standard 115V or 230V socket using the included HANNA adapter or into a 12 VDC source such as a car's 12 volt accessory outlet. Good Laboratory Practice Calibration data, date and ID information are stored for retrieval at a later date. HANNA instruments ION SELECTIVE MEASUREMENT ® 15 Measurement: Incremental Methods HI 4222 pH/ISE Bench Meter with Special ISE Features for Ease of Use Incremental Methods are useful techniques used to determine ion concentration quickly in samples whose constituents are variable or concentrated. Incremental methods have some inherent advantages over direct potentiometry. The techniques can reduce errors from variables such as temperature, viscosity, pH or ionic strength. The electrodes remain immersed throughout the process thus reducing sample carry over and possible liquid junction changes in the reference and analysis steps are reduced. Known Addition, Known Subtraction, Analyte Addition, and Analyte Subtraction methods are four of these incremental techniques. All techniques involve adding a standard to the sample, or sample to the standard and the meter calculates the sample’s ion concentration directly. Instrument Features • Incremental methods: Known addition Known subtraction Analyte addition Analyte subtraction • Direct methods • pH with Calibration Check™ technology • • • • • Stability indicator Calibration information Single or dual display Colored graphic display Dual channel measurement and logging • Help screens at the touch of a key • Multi-language interface • Manual or automatic temperature compensation • Opto-isolated USB and RS232 outputs • Data logging pH electrode, temp. probe, pH solutions and electrode holder included Large, dot-matrix COLOR LCD w/backlight 16 ION SELECTIVE MEASUREMENT HANNA instruments ® Measurement: Incremental Methods First Step The first step in performing an incremental method analysis is to enter the required parameters including sample, ISA and standard volumes and standard concentration. When repeating the analysis on another sample, the parameters do not need to be reentered. Sequence of Readings Once the variables are entered, the user is guided step-by-step through the measurement. Results The results are automatically calculated and shown together with all the parameters used. Help Screen Users can consult the on-screen help from any mode simply by pressing the HELP key. The initial mV measurement is made before the addition, next is the addition, and then the second measurement is made. At this time, results can be saved into a log file. If necessary, the user can edit the parameters without having to redo the entire analysis. The instrument will then display the meaning and options available of the current screen. SPECIFICATIONS pH Dual-graph capability and real-time logging mV Range Resolution Accuracy Range Resolution Accuracy Range ISE Resolution Accuracy Range Temperature Resolution Accuracy Relative mV Offset Range Input Channels Calibration Check pH Calibration ISE Calibration Temperature Compensation pH electrode Temperature probe Log-on-demand Logging Intervals PC Connection Display Menu Languages Input impedance ORDERING INFORMATION HI 4222-01 (115V) and HI 4222-02 (230V) are supplied with glass body pH electrode, temperature probe, power adapter, pH 4 and pH 7 buffer solutions, electrode refilling solution, electrode holder and instructions. HANNA instruments ® Power Environment Dimensions Weight HI 4222 -2.00 to 20.00; -2.000 to 20.000 pH 0.1 pH; 0.01 pH; 0.001 pH ±0.1 pH; ±0.01 pH; ±0.002 pH ±2000 mV 0.1 mV ±0.2 mV 1 x 10-7 to 9.99 x 1010 concentration (choice of units) 1; 0.1; 0.01; 0.001 concentration ±0.5% (monovalent ions); ±1% (divalent ions) -20.0 to 120°C; -4.0 to 248.0°; 253.15 to 393.15K 0.1°C; 0.1°F; 0.1K ±0.2°C; ±0.4°F; ±0.2K ±2000 mV 2 Status of electrode condition and response time; Status of the buffer solutions during calibration Automatic, up to 5 points with 8 standard buffers available (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + 5 custom buffers Automatic, up to 5 points with 5 fixed standard solutions available for each measurement unit + 5 custom solutions Automatic or manual from -20.0 to 120.0°C (-4 to 248°F) HI 1131B (optional) HI 7669/2W stainless steel probe (optional) 100 lots, 5000 samples per lot 1, 2, 5, 10, 30 seconds Opto-isolated USB and RS232 240 x 320 dot-matrix LCD English, Italian, Spanish, French 1012 ohm 12 VDC adapter (included) 0 to 50°C (32 to 122°F) 95% RH 160 x 231 x 94 mm (6.3 x 9.1 x 3.7”) 800 g (1.8 lbs.) ION SELECTIVE MEASUREMENT 17 Measurement: Potentiometric Titrations HI 901 • HI 902 Automatic Titrators a Potentiometric Titration can increase the precision of ISE measurements and also the number of ionic species that can be determined. ISEs are commonly used as indicators for the titrant or sample species to follow the progress of a precipitation or complexation titration. A small change in reactant addition corresponds to a large change in electrode potential at the stoichiometric end point. An example of a precipitation titration is the determination of chloride using silver nitrate. A Silver ISE can be used to follow this titration. A complexometric titration is used for the determination of calcium. A calcium solution is titrated with the complexing reagent EDTA. During the titration there is a gradual decrease in the free Ca+2 ion concentration as more EDTA is added. The end point corresponds to the point when all the Ca+2 is complexed. The progress of this titration can be monitored using a calcium ISE. Instrument Features • 320 x 240 pixel LCD w/backlight. • Precise dosing system (accuracy under 0.1% of burette volume). • Support up to 100 titration methods (standard and user defined). • Clip Lock™ — change burettes quickly with auto burette recognition • Dynamic/Linear dosing feature. • Fixed end point potential or pH. • Equivalence point detection (first derivative and second derivative). • The results are displayed directly in the selected units. • Titration graph can by displayed on-screen & saved. • User customized reports can be printed, saved on floppy disk or transferred to PC via RS232 interface. • Reminders for titrant age and standardization expiration. • Self diagnostic features for peripheral devices including pump, valve, burette and stirrer. Burette, pH electrode, temp. probe and stirrer assembly included 18 ION SELECTIVE MEASUREMENT HANNA instruments ® Measurement: Potentiometric Titrations With Clip-Lock™, it only takes a couple seconds to exchange the reagent burettes to perform a different titration. With conventional titrators, there is the risk of cross contamination of titrants when exchanging reagents. Reconfiguring the titrator for different sample methods also consumes time and reagents. Each method may need different reagents and care must be used when purging and cleaning the burette. To avoid these problems, HANNA provides the Clip-Lock™ exchangeable burette system to prevent cross contamination while reducing loss of time and reagents. Having several prepared burettes on hand will make the HANNA 900 series the SPECIFICATIONS Range Resolution Accuracy Burette Sizes fastest, most versatile titration systems available. Interrupting an important cycle of analysis due to a malfunctioning burette is a thing of the past. With the HANNA Clip-Lock™ system you can simply substitute the burette and complete all your tests with the same titrant! HANNA’s burettes feature a threaded screw connection to prevent leakage problems. Burettes are available in 5 mL, 10 mL & 25 mL sizes and are made of chemically resistant material to ensure many years of trouble-free operation. Keep extra HANNA 900 series burettes on hand for quick substitutions without changing the titrant! mV pH Temperature -2000.0 to 2000.0 mV -2.000 to 20.000 pH -5.0 to 105.0°C/23 to 221°F/268.2 to 378.2 K 0.1 mV 0.1/0.01/0.001 pH 0.1°C/0.1°F/0.1K ±0.1 mV (@25°C/77°F) ±0.001 pH (@25°C/77°F) ±0.1°C/±0.2°F/±0.1K (excluding probe error) 5, 10, and 25 mL Burette Resolution 1/40000 Display Resolution 0.001 mL Dosing Accuracy ±0.1% of full burette volume Display Graphic LCD, 320 x 240 pixel LCD Languages English, Italian, Portuguese, Spanish Methods Up to 10,000 methods (standard and user-defined) Burette Auto-Detection Burette size is automatically recognized when inserted into the unit Programmable Stirrer Propeller type, 100-2500 RPM, automatically held within 10% of the set value, resolution 100 rpm Flow Rate User-selectable from 0.1 mL/min to 2 x burette volumes/min pH/mV Measurement Titrators can also perform direct pH and mV measurements Temperature Compensation Manual or automatic (ATC) pH Calibration Manual or automatic at 1-5 points with 4 buffer sets or custom buffers Potentiometric Titrations Acid-Base (pH or mV-Mode), Redox, Precipitation, Complexometric, Non-Aqueous, Ion-Selective, Argentometric (in mV-mode only) HI 901 Titration Methods Fixed mV or pH end-point detection & first equivalency point detection (with the 1st or 2nd derivatives) HI 902 Titration Methods Fixed mV or pH end-point detection & multiple equivalency point detection (with the 1st or 2nd derivatives); back titration Measurement Units User specified expression of concentration units to suit specific calculation requirements mV-Volume or pH-Volume titration curve, 1st derivative curve or 2nd derivative curve, in pH-mode or mV-mode; pH/mV values versus time-datalogging results Real Time & Stored Graphs Data Storage: Up to 100 complete titration and pH/mV logging complete reports Disk Drive: Built-in 3.5" floppy disk drive allows storage and transfer of configurations, preprogrammed methods, custom methods, titration reports and bitmap graph files Peripherals Connections for VGA display, PC-keyboard, parallel printer, RS 232 input, interface for future expansion GLP Conformity Instrumentation data storage and printing capabilities Operating Environment 10 to 40°C (50 to 104°F), up to 95% RH Storage Environment -20 to 70°C (-4 to 158°F), up to 95% RH Power 110V/220 Vac; 50-60Hz Dimensions Width x Depth x Height = 390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in) Weight approx. 10 kg (22 lbs.) with one pump and stirrer assembly ORDERING INFORMATION HI 901-01 (115V) and HI 901-02 (230V) is supplied with (1) 25 mL glass burette, (1) burette driver assembly, power adapter and instructions. HI 902-01 (115V) and HI 902-02 (230V) back titration and multiple end-point titrators are supplied with (1) 25 mL glass burette, (1) burette driver assembly, power adapter and instructions. HANNA instruments ® ION SELECTIVE MEASUREMENT 19 For more information or for a distributor near you: 800.504.2662 [email protected] www.hannainst.com At HANNA we design and Authorized Distributor manufacture the most complete range of analytical products. We strive to work with you to develop a HANNA solution to address your specific instrumentation needs —on your budget. Solid build quality, helpful customer service and competitive pricing place us ahead of the competition. Since 1978, more and more professionals all over the world choose and recommend HANNA for their laboratory testing needs. P/L ISEMEASUREMENT 2.0 PRINTED IN USA Hanna Instruments® reserves the right to change or modify its products at any time without advance notice.