Delta Electronics Environmental Management System (EMS) monitors the environment and conditions in the data center, including temperature, humidity, water leakage, as well as alarms for fire, smoke, and unauthorized entry. The EMS offers managers an integrated platform for more convenient monitoring of today’s data center.
View more...
   EMBED

Share

Preview only show first 6 pages with water mark for full document please download

Transcript

Delta Electronics Environmental Management System (EMS) monitors the environment and conditions in the data center, including temperature, humidity, water leakage, as well as alarms for fire, smoke, and unauthorized entry. The EMS offers managers an integrated platform for more convenient monitoring of today’s data center. EnviroStation EnviroStation integrates the monitoring of the data center’s environment and other conditions, and sends the data to a central manager via network. User-defined alarms ensure the data center’s security. The first line to ensure data center security The power behind competitiveness Delta InfraSuite EMS EnviroStation EnviroProbe Easy to manage •Assess and collect key data center information for enhanced management •Real-time notification providing faster management response and more effective operations •Setting manager password for greater security •SNMP Trap allowing easy integration with any enter- prise management system Convenience •Monitoring via internet browser •InsightPower Manager remote monitoring software providing prompt handling of any data center situation •Graphical interface and historical data records for more effective management •Real-time alarm notifications shorten management response time Flexibility •Support SNMP communication protocol •Set each alarm value according to actual requirements Technical Specifications Model Input Output Network Connection Alert Environment Dimensions Weight Power Digital Input Analog Input Resistance Temperature Detection Leakage Sensor HUB Delta Bus Relay Output RJ 45 RS485 (X2) Console Warning Light Operating Temperature Storage Temperature Operating Humidity Product (W x D x H) Product 100~240 Vac, 50/60 Hz Wet Contact Signal •Alarm Voltage 5~24 Vdc, 1-9 mA Dry Contact Signal •Normal: Off (open circuit) •Alarm: On (short circuit) Voltage: 0~10Vdc Current: 4~20 mA Support 2-wire or 3-wire resistance Range: 0~50°C Accuracy: ±1°C with 3-wire PT100 Detect Voltage <1V (alarm signal with S-1FP leak sensor) For connection with sensor devices (such as smoke detectors, fire detectors, or door sensors, etc) and support: +12V, 0.8A (max) +24V, 1.0A (max) One port limit 0.6A +12V, 0.8A (max) 26 Vdc (max), 0.8A (max) 10/100 Base-T Standard ModBus Connect to PC via RJ -45 to DB9 cable (cable is included in the package) A configuration port is available for the console mode. Included in the package and can connect to EMS2000 via a Sensor Hub converter (through Port 1 or Port 2) to alert for abnormal conditions. 0~45°C -20°C ~60°C 0~90% RH (non-condensing) 440 x 157 x 44 mm 2.4 Kg •All specifications are subject to change without prior notice. EMS2000 Protocol: • IPv4/ IPv6 • DHCP • HTTP/ HTTPS • SNMP v1/v3 • Telnet/ SSH • FTP/ SFTP/ TFTP • SMTP • SNTP • syslog • RADIUS EnviroProbe EnviroProbe offers temperature and humidity monitoring in a single rack or a specified area. It also provides 4 contact closure inputs for environment sensor devices that monitor data center conditions such as security, water, fire and smoke, and it can also send the data to management via network. Easy to manage •Monitoring temperature and humidity of the environ- ment •Backlight LCD display •4 contact closure inputs for monitoring other environ- mental devices Convenience •Monitoring via internet browser •InsightPower Manager software for remote monitoring and recording •Supporting RS232 or RS485 communication Flexibility •Supports SNMP communication protocol •Cascade up to 10 EnviroProbes via RS485 Technical Specifications Model name Voltage Input Indicator Dimensions (HxWxD) Weight Temperature Humidity Altitude Conformance EMS1000 UPS SNMP card: 12 Vdc (pin 1 & 4) PDU SNMP card: 5 Vdc (pin 2 & 4) Temperature, Humidity Unit: 30 x 66 x 99 mm Package: 43 x 97 x 110 mm Unit: 120g Shipping: 140g Measurement: 0 ~45°C Storage: -20 ~60°C Accuracy: ±1°C @ 15 ~35°C ±2°C @ 0 ~15°C and 35 ~45°C Measurement: 20 ~90% RH (Non-condensing) Storage: 0 ~90% RH (Non-condensing) Accuracy: ±10% RH 0 ~+10,000 ft CE EN55022 (CISPR 22) Class B •All specifications are subject to change without prior notice. Delta InfraSuite EMS www.deltapowersolutions.com Leaflet_InfraSuite_EMS_en-us_V1 Backlight LCD display Cascade up to 10 EnviroProbes