En_de_lr

Phoenix
View more...
   EMBED

Share

  • Rating

  • Date

    December 1969
  • Size

    6.4MB
  • Views

    483
  • Categories

Preview only show first 6 pages with water mark for full document please download

Transcript

Power & Signal Quality TRABTECH Surge Protection Arresters for every application Interference-free mains supply and signal transmission A constant power supply and secure data links are especially important for the operational reliability of electrical systems, installations, and devices. Phoenix Contact meets these requirements with the comprehensive TRABTECH product range. Tailored solutions consisting of surge protection, monitoring, device circuit breakers, and EMC products ensure a consistently high power and signal quality for maximum availability. Surge protection Monitoring Device circuit breakers EMC solutions 2 PHoENIx CoNTACT Services Table of contents Surge voltages – the underestimated danger The protective circuit for safety all round Page 4 Surge protection for the power supply unit Page 6 Surge protection for measurement and control technology Page 12 Surge protection for information technology Page 16 Surge protection for transceiver systems Page 20 Every day there are more than four million lightning discharges worldwide.* Of these, ten percent are considered as ground lightning strikes with surge currents of up to 200,000 A. In addition to these daily 400,000 discharges caused by storms, surge voltages also occur within local power grids. Here, it is switching operations, faults or switched-mode power supply units, for example, that are responsible. Regardless of the cause, surge voltages repeatedly lead to unexpected faults in devices or system failures. TRABTECH surge protection prevents such effects comprehensively and effectively. * Source: en.Wikipedia.org > Lightning Residential buildings, fire 120.000 20.000 60.000 Household contents, fire 330.000 30.000 60.000 Device failure or defects caused by surge voltages are more frequent than expected. According to the statistics of German insurers - GDV, this is the most frequent cause of damage. These figures only apply to damage that resulted in fire. Surge voltage Lightning Other Source: GDV Die Deutschen Versicherer 2009 (GDV, the German Insurers 2009) PHoENIx CoNTACT 3 The protective circuit for safety all round The principle of the protective circuit defines a comprehensive safety measure against surge voltages. An imaginary circle encloses devices, plants or systems to be protected. Surge protection devices that correspond to the nominal data of the respective power supply unit or signal type are to be installed at all points where lines cut this circle. In order to protect objects consistently from conductor-specific surge voltage couplings, the following areas must be considered: Power supply Perfectly coordinated arresters for feeders, distributors and termination devices guarantee the power supply. MCR technology Optimized arresters are available for different types of signals and measuring principles. Information technology High-speed protection (CAT.6+) for data and communication technology. Transceiver technology This keeps local communication, mobile phones and satellite or wireless systems on the air whatever the weather. 4 PHoENIx CoNTACT PHoENIx CoNTACT 5 Surge protection for the power supply unit Efficient protection against surge voltage always starts in the power supply unit. A multi-stage protection concept made up of performance-related lightning current and surge arresters is considered to be the most reliable basis. Protection level, type 1: High-capacity lightning arresters Protection level, type 2: Surge protection, which should not be missing in any power supply Protection level, type 3: Surge protection for sensitive devices Further arrester combinations are a sensible addition to the product range. Plugging instead of screwing Universal pluggability ensures a high degree of comfort during insulation measurements in the system, for example. Instead of tampering with the installation, just pull out the plug. Whichever way you turn it The protective devices of the compact series can be installed flexibly. This avoids unnecessary cable lengths and offers optimum protection for any installation environment. Status at a glance Each arrester plug has its own mechanical display to display its functional status. Remote signaling A common floating PDT contact makes remote signaling possible without taking up extra space. Regardless of the type of signal (current, voltage), the interface can be used as N/C or N/O contact. 6 PHoENIx CoNTACT Lightning arrester, type 1 FLASHTRAB compact PLUS: Powerful spark gap technology for power supply systems up to 240 / 415 V AC. • Type 1 lightning arrester with low protection level • For low-voltage high-current systems with high short-circuiting power • For the main power distribution/industrial distribution • In pre-meter or post-meter area • At the transition of lightning protection zones LPZ* 0A LPZ 1 • For buildings with external lightning protection • For buildings with overhead line supply TN-S / TT systems TN-C systems L1 FLT-CP-PLUS-3S-350 Order No. 2882640 L2 L1 L3 L3 N PEN L1 FLT-CP-PLUS-2S-350 Order No. 2882666 L2 m 4m 10 8m 4-conductor system 14 5-conductor system m PE FLT-CP-PLUS-3C-350 Order No. 2882653 L2 L1 FLT-CP-PLUS-2C-350 Order No. 2882679 L2 PEN N L1 FLT-CP-PLUS-1S-350 Order No. 2882682 N 72 mm 3-conductor system 10 4-conductor system 8m m PE FLT-CP-PLUS-1C-350 Order No. 2882695 L1 PEN PE FLT-CP-PLUS... IEC category/EN type Lightning protection level Nominal voltage UN Maximum continuous voltage UC Follow current quenching capacity Ifi Lightning test current Iimp (10/350)μs Nominal discharge surge current In (8/20)μs Protection level Up Backup fuse max. acc. to IEC 61643-1 ...3S-350 ...3C-350 mm 36 mm 2-conductor system 72 3-conductor system ...2S-350 ...2C-350 ...1S-350 ...1C-350 I / T1 I 100 kA I II II 230/400 V AC ... 240/415 V AC 50/60 Hz 350 V AC 50/60 Hz L-N (L-PEN) 50 kA (264 V AC) 75 kA 75 kA 50 kA 25 kA (per channel) ≤ 1.5 kV 315 A gL/gG III – IV III – IV 230 V AC ... 240 V AC 50/60 Hz 50 kA 25 kA * LPZ: Lightning Protection Zone PHoENIx CoNTACT 7 Lightning current and surge arresters, type 1 + type 2 FLASHTRAB compact: Combination of lightning current and surge arresters for power supply systems up to 240 / 415 V. • Combined arresters, type 1 and type 2 • For the main power distribution/industrial distribution • In the post-meter area • At the transition of lightning protection zones LPZ* 0 LPZ 2 • For buildings with external lightning protection • For buildings with overhead line supply TN-S / TT systems TN-C systems L1 FLT-CP-3S-350 Order No. 2859712 L2 L1 L3 L3 N PEN L1 FLT-CP-2S-350 Order No. 2859767 L2 m 8m 10 4m 4-conductor system 14 5-conductor system m PE FLT-CP-3C-350 Order No. 2859725 L2 L1 FLT-CP-2C-350 Order No. 2859770 L2 PEN N L1 FLT-CP-1S-350 Order No. 2859738 N mm 72 8m 3-conductor system 10 4-conductor system m PE FLT-CP-1C-350 Order No. 2859741 L1 PEN FLT-CP-... IEC category/EN type Lightning protection level Nominal voltage UN Maximum continuous voltage UC Follow current quenching capacity Ifi Lightning test current Iimp (10/350)μs Nominal discharge surge current In (8/20)μs Protection level Up Backup fuse max. acc. to IEC 61643-1 * LPZ: Lightning Protection Zone 8 PHoENIx CoNTACT ...3S-350 I 100 kA ...3C-350 ...2S-350 ...2C-350 I + II / T1 + T2 I II II 230/400 V AC ... 240/415 V AC 50/60 Hz 350 V AC 50/60 Hz L-N (L-PEN) 25 kA (264 V AC) 75 kA 75 kA 50 kA 25 kA (per channel) ≤ 1.5 kV 315 A gL/gG 36 mm 2-conductor system 72 3-conductor system mm PE ...1S-350 ...1C-350 III – IV III – IV 230 V AC ... 240 V AC 50/60 Hz 50 kA 25 kA Surge arrester, type 2 VALVETRAB compact: Space-saving surge arresters for all standard power supply systems up to 240 / 415 V. • Surge arrester, type 2 • In sub-distribution boards and distribution boxes on the various floors • Upstream of the residual current circuit breaker • At the transition of lightning protection zones LPZ* 0B LPZ 1 / LPZ 1 LPZ 2 • For buildings without external lightning protection TN-S / TT systems TN-C systems L1 VAL-CP-3S-350 Order No. 2859521 L2 L1 VAL-CP-3C-350 Order No. 2859547 L2 L3 L3 N PEN L1 VAL-CP-2S-350 Order No. 2859505 L2 36 mm 4-conductor system 48 5-conductor system mm PE L1 VAL-CP-2C-350 Order No. 2859589 L2 PEN N L1 24 mm 3-conductor system 36 4-conductor system mm PE VAL-CP-1S-350 Order No. 2859563 N VAL-CP-... IEC category/EN type Nominal voltage UN Maximum continuous voltage UC Nominal discharge surge current In (8/20)μs Max. discharge surge current Imax (8/20)μs Protection level Up Backup fuse max. acc. to IEC 61643-1 24 3-conductor system mm PE ...3S-350 ...3C-350 ...2S-350 ...2C-350 II / T2 230/400 V AC ... 240/415 V AC 50/60 Hz 350 V AC 50/60 Hz L-N (L-PEN) 20 kA (per channel) 40 kA (per channel) ≤ 1.4 kV 125 A gL/gG ...1S-350 230 V AC ... 240 V AC 50/60 Hz Note: VALVETRAB compact is also available for 120 V power supply systems or as a residual current free variant (VF-type). * LPZ: Lightning Protection Zone PHoENIx CoNTACT 9 Surge arrester, type 2 – combined solutions Combi-RCD*: Surge protection with residual current circuit breaker FI circuit breaker (RCD) Surge arrester (VAL-CP) Sensitive for residual currents: Type A IEC category/EN type: II / T2 Rated residual current IΔn: 30 mA/300 mA Discharge surge current Imax (8/20) μs: 30 kA/path Release time at IΔn: ≤ 300 ms Maximum continuous voltage UC: 350 V AC VAL-CP-RCD-3S/40/0.03 Order No. 2882802 VAL-CP-RCD-3S/40/0.3/SEL Order No. 2808001 Nominal voltage UN: 230/400 … 240/415 V AC Nominal load current IL: 40 A Dimensions (W x H x D): 120 mm x 90 mm x 75 mm The Combi-RCD combines the properties of a residual current circuit breaker* and a type 2 surge arrester in a single housing. This innovative “2 in 1” concept defines an entirely new device type for the simultaneous protection of persons and devices. * Residual current device = RCD 72 mm m 4m 11 13 1.5 mm Combi-MCB**: Surge protection with a coordinated backup fuse VAL-CP-MCB-3S-350/40/FM VAL-CP-MCB-3C-350/40/FM VAL-CP-MCB-1S-350/40/FM Order No. 2882750 Order No. 2882776 Order No. 2882763 IEC category/EN type: II / T2 Nominal voltage UN: 230/400 V AC ... 240/415 V AC Maximum continuous voltage UC: 350 V AC Nominal discharge surge current In (8/20) μs: 20 kA/path Protection level UP: ≤ 2.5 kV The integrated arrester backup fuses of the VAL-CP-MCB ensure maximum utilization of the performance capability of the surge protection. Their application is independent of the operating current fuses of the system – Faults in connection with fuses for surge protection are thus ruled out. ** Mains Circuit Breaker = MCB 10 PHoENIx CoNTACT Device protection, type 3 PLUGTRAB TN-S / TT systems L1 PLUGTRAB TN-S / TT / IT systems L1 L2 N L3 PE 35 17 .4 .7 mm mm N PE 230 V / 400 V PT 4-PE/S-230AC/FM PT ... Nominal voltage UN BLOCKTRAB 2858357 2805130 2856812 2800457 2800961 ... 2-PE/S-24AC 24 V AC 275 V AC 253 V AC 275 V AC [L-N] 440 V AC [L(N)-PE] 150 V AC 34 V AC / 44 V DC 26 A 1.5 kA (per channel L-N) 4.5 kA (per channel L-N) ≤ 1.2 kV/≤ 1.5 kV 26 A 3 kA 10 kA ≤ 1.1 kV/≤ 1.5 kV 26 A 3 kA 8 kA ≤ 1.2 kV/≤ 1.5 kV 26 A 2.5 kA 10 kA ≤ 620 V/≤ 850 V 26 A 1 kA 2 kA ≤ 180 V/≤ 550 V 22.5 mm SOCKETTRAB 26.2 mm N mm PE 230 V .9 mm 42 .9 42 TN-S / TT / IT systems L1 26.2 mm N MAINTRAB No. No. No. No. No. ... 2-PE/S-120AC 120 V AC TN-S / TT / IT systems 230 V Order Order Order Order Order ... 2-IT-... 230 V AC PE For every commercially available distribution box and for 60 mm deep installation box 2-PE/S-230AC/FM 2-IT-230AC/FM 2-PE/S-120AC/FM 2-PE/S-24AC/FM 2-PE/S-60AC/FM ... 2-PE/S-230AC 230 V AC 22.5 mm L1 PT PT PT PT PT ... 4-PE/S-230AC 230 V AC Maximum continuous voltage UC Nominal current IN Nominal discharge surge current In (8/20)μs Max. discharge surge current Imax (8/20)μs Protection level Up: L-N / L(N)-PE 230 V 230 V IT 120 V 24 V 60 V Order No. 2882459 BT-1S 230AC/A BT-1S-230AC/O Order No. 2803409 Order No. 2800625 TN-S / TT systems L1 For every commercially available flush-type or cable duct socket BT-SKT 230/A Order No. 2859343 COMBITRAB TN-S / TT systems L1 N N PE PE 230 V 230 V Socket attachment plug combined with antenna or telecommunication protection D, A, NL, N, FIN ... with SAT connection ... with ISDN connection ... with TAE connection E, P S, FIN, N CH D, A, NL, E, P B, F, CZ, SVK, PL Multi-socket strip combined with TV/SAT or ISDN protection MNT-1 D MNT-TV-SAT D MNT-ISDN D MNT-TAE D MNT-1 E MNT-1 S/WH MNT-1 CH II MNT-POWERLINE MNT-NET B/F Order Order Order Order Order Order Order Order Order No. No. No. No. No. No. No. No. No. 2882200 2882284 2882336 2882381 2882239 2880862 2882255 2858001 2882226 ...with TV-SAT connection ... with ISDN connection CBT-SCHUKO Order No. 2857280 CBT-TV-SAT CBT-ISDN Order No. 2857303 Order No. 2857316 PHoENIx CoNTACT 11 Surge protection for measurement and control technology Signal interfaces are particularly sensitive to surge voltages. Combined protective circuits with components which are powerful and respond quickly are used in this case. In addition, the arresters of the PLUGTRAB family are impressive thanks to their practical functions. The plug-in capability of the arresters allows a function check, even during system operation. This selection guide helps you find the right protection quickly and easily in line with the application – giving you greater availability. Forward-looking monitoring PLUGTRAB PT-IQ performs multi-stage monitoring of all protective devices. A controller supplies up to 28 devices with voltage and implements remote signaling. Permanent installation Individual DIN rail connectors can be converted into a bus using PT-IQ. This transmits voltage and status information. Conventional wiring is not used. Error-free installation Voltage keying and protection against polarity reversal. Incorrect connection is not possible. Space-saving installation Up to five signal lines can be protected with one device. This requires a design width of just 17.5 mm on the DIN rail. 12 PHoENIx CoNTACT Intelligent and systematic surge protection Grounding PLUGTRAB PT-IQ is a range of self-monitoring surge protective devices with multi-stage status indicator. A controller supplies up to 28 protection modules with voltage, collects the status of all connected protection devices and implements remote signaling via a DIN rail bus (T-BUS). A surge protective device consists of the plug, base element and T-BUS adapter. GND Indirect grounding Direct grounding In the PT…+F-… or -BE modules, the connections for the shield or the reference potential are connected to the metal mounting foot and therefore the DIN rail via a gasfilled surge arrester. In the PT-…-UT or -BE modules, the connections for the shield or the reference potential are connected to the DIN rail via the metal mounting foot. Floating signal circuits Controller for voltage supply Protection device Indirect grounding Direct grounding Protection for two double conductors* e.g., standard signals 0/4 ... 20 mA PT-IQ-PTB-UT Order No. 2800768 + PT-IQ-1x2+F-24DC-UT Order No. 2800977 PT-IQ-1x2-24DC-UT Order No. 2800976 Protection for two double conductors e.g., standard signals 0/4 ... 20 mA PT-IQ-PTB-UT Order No. 2800768 + PT-IQ-2x2+F-24DC-UT Order No. 2800981 PT-IQ-2x2-24DC-UT Order No. 2800980 PT-IQ-PTB-UT Order No. 2800768 + PT-IQ-2x1+F-24DC-UT Order No. 2800788 PT-IQ-2x1-24DC-UT Order No. 2800787 PT-IQ-PTB-UT Order No. 2800768 + PT-IQ-4x1+F-24DC-UT Order No. 2800983 PT-IQ-4x1-24DC-UT Order No. 2800982 Signal circuits with common reference potential Protection for two conductors* e.g., binary switching signals Protection for four conductors e.g., binary switching signals * other voltage levels are available > www.phoenixcontact.com PHoENIx CoNTACT 13 PLUGTRAB PT – plug-in surge protection PLUGTRAB PT consists of base element and protective plug. Various different grounding options were implemented via the corresponding base element. Each protective plug can be tested using the Checkmaster arrester test device. Floating signal circuits The products on this page support the HART protocol** Protection for a double conductor* e.g., standard signals 0/4 … 20 mA Protection for two double conductors* e.g., standard signals 0/4 … 20 mA Plug Base element Indirect grounding Direct grounding + PT 1x2+F-BE Order No. 2856126 PT 1x2-BE Order No. 2856113 + PT 2x2+F-BE Order No. 2839224 PT 2x2-BE Order No. 2839208 PT 1x2-12DC-ST Order No. 2856029 PT 1x2-24DC-ST Order No. 2856032 PT 2x2-12DC-ST Order No. 2838254 PT 2x2-24DC-ST Order No. 2838228 Protection for intrinsically safe circuits one or two double conductors PT 2xEX(I)-24DC-ST Order No. 2838225 + Protection for temperature, 2, 3 or 4-wire measurement PT 4-24DC-ST Order No. 2839240 + Protection for intrinsically safe circuits 2, 3 or 4-wire measurement PT 4-EX(I)-24DC-ST Order No. 2839253 + – PT 4+F-BE Order No. 2839415 – PT 2xEX(I)-BE Order No. 2839279 PT 4-BE Order No. 2839402 PT 4-EX(I)-BE Order No. 2839486 * other voltage levels are available > www.phoenixcontact.com ** HART = Highway Addressable Remote Transducer Protocol (Phoenix Contact is a registered member of the HART Communication Foundation) 14 PHoENIx CoNTACT Signal circuits with common reference potential Plug Protection for two conductors* e.g., binary switching signals Protection for four conductors* e.g., binary switching signals Protection for high signal voltages* Base element PT 2x1-24DC-ST Order No. 2856074 Indirect grounding Direct grounding + PT 2x1+F-BE Order No. 2856142 PT 2x1-BE Order No. 2856139 + PT 4x1+F-BE Order No. 2839376 PT 4x1-BE Order No. 2839363 PT 2x1-24AC-ST Order No. 2856100 PT 4x1-24DC-ST Order No. 2838319 PT 4x1-24AC-ST Order No. 2838351 PT 2x1VA-120AC-ST Order No. 2839185 + – PT 2x1VA-230AC-ST Order No. 2839198 PT-BE/FM Order No. 2839282 Single-stage protection with gas-filled arrester as coarse protection Protection for two conductors PT 2-F-ST Order No. 2859000 + – PT-BE/FM Order No. 2839282 Protection for four conductors PT 4-F-ST Order No. 2858441 + – PT 4-BE Order No. 2839402 Further surge protection devices for measurement and control technology LINETRAB – the standard in the 6.2 mm class SURGETRAB – Protection directly at the measuring head TERMITRAB – Protection in the modular terminal block PHoENIx CoNTACT 15 Surge protection for information technology Reliable data exchange and telecommunication is indispensable nowadays. Sensitive systems operate at high frequencies with low signal levels and expansive networking. Surge voltages would here result in widespread failures and, in the worst case, data loss. 65 mm 1 m 00 m The DATATRAB series can be used as adapter or DIN rail module. 25 mm This selection guide helps you find the right protection quickly and easily in line with the application – giving you greater availability. The perfect fit Small and modular Two-channel protective plug for CT-TERMIBLOCK and LSA-Plus strips. Many applications and just one solution Solutions on the basis of PLUGTRAB series are especially suitable for installation in the control cabinet. 16 PHoENIx CoNTACT Information and data technology (BUS systems) Plug Base element* Indirect grounding Direct grounding PT 3-PB-ST Order No. 2858030 + – PT 1X2-BE Order No. 2856113 INTERBUS-INLINE remote bus PT 5-HF-5DC-ST Order No. 2838762 + PT 2X2+F-BE Order No. 2839224 – INTERBUS-INLINE (I/O) Analog PT 2X2-24AC-ST Order No. 2838283 + – PT 2X2-BE Order No. 2839208 INTERBUS-INLINE (I/O) Digital PT 4X1-24AC-ST Order No. 2838351 + – PT 4X1-BE Order No. 2839363 PT 2XEX(I)-24DC-ST Order No. 2838225 + – PT 2XEX(I)-BE Order No. 2839279 Profibus DP Profibus PA Foundation Fieldbus * For an explanation, see page 13 "Grounding" ETHERNET (inkl. PoE) - 100 Base T - 1000 Base T - 10G Base T TOKEN Ring VG-AnyLAN DT-LAN-CAT.6+ Order No. 2881007 PROFINET ETHERNET - 100 Base T - 1000 Base T TOKEN Ring D-LAN-19“-24 Order No. 2838791 D-LAN-19“-16 Order No. 2880147 High-speed data protection The DATATRAB family is synonymous with effective surge protection for high-speed data transfers. Accessories RJ45 patch cable, length: 0.5 m FL CAT6 PATCH 0,5 Order No. 2891288 RJ45 patch cable, length: 3 m FL CAT6 PATCH 3,0 Order No. 2891686 As a result, the DT-LAN-CAT.6+ provides universal protection for network speeds up to 10 Gbps without influencing the signals. PHoENIx CoNTACT 17 Data technology (serial interfaces) Plug Base element Indirect grounding Direct grounding Data systems RS 485 RS 422A PT 5-HF-12DC-ST Order No. 2838775 + PT 2X2+F-BE Order No. 2839224 – Data systems RS 232 C PT 3-HF-12DC-ST Order No. 2858043 + PT 1X2+F-BE Order No. 2856126 – Telecommunications ADSL, HDSL, T-DSL, V-DSL Analog telephony ISDN UK0 PT 2-TELE Order No. 2882828 ADSL, HDSL, T-DSL, V-DSL Analog telephony ISDN UK0 ATM ISDN S0 ISDN S2M Analog telephony Coarse protection with fail-safe contact Analog telephony Coarse protection with fail-safe contact and power cross protection Analog telephony Coarse and fine protection 18 PHoENIx CoNTACT DT-TELE-RJ45 Order No. 2882925 DT-LAN-CAT.6+ Order No. 2881007 CTM 2X1-180DC-GS Order No. 2838636 CTM 2X1-180DC-GS-P Order No. 2838623 CTM 1X2-110AC Order No. 2838539 RS 485 DT-UFB-485/BS Order No. 22920612 RS 232 C / V.24 with D-SUB 9 connection DT-UFB-V24/S-9-SB Order No. 2803069 RS 232 C / V.24 with adapter cable from D-SUB 9 on D-SUB 25 DT-UFB-V24/S-SB-SET Order No. 2803072 ADSL/T-DSL - Up to 16,000 kbps Analog telephony CTM 1X2-110AC Order No. 2838539 ISDN UK0 ISDN S0 ISDN S2M CTM ISDN Order No. 2838555 Accessories Magazine with grounding rail - To accommodate up to 10 CTM connectors CTM 10-MAG Order No. 2838610 Disconnect strip screw terminal block - For standard rails of type NS-32 and NS-35/7.5 - compatible with the CTM 10-MAG with connections for 20 conductors up to 4 mm2 and with disconnect contacts for CTM protective connectors CT-TERMIBLOCK 10DA Order No. 0441711 PHoENIx CoNTACT 19 Surge protection for transceiver systems The high frequencies of wireless transmission require the use of protective devices with reduced insertion attenuation. COAXTRAB fulfills this requirement. The coaxial arresters are suitable for all common transmission systems in mobile and public safety wireless networks in the field of video or television transmission. Customized products Thanks to their very low attenuation values, surge protection devices ensure interference-free signal transmission in all standard applications. Shielding Good shielding properties are indispensable for a “clean” transmission. Robust metal housings ensure a perfect shielding and are suitable for use in harsh environments. Connection technology A connection system suitable for the relevant application: F and N connector, TV connector and 7/16, UHF, BNC connections. Many applications and just one solution Solutions on the basis of PLUGTRAB series are especially suitable for installation in the control cabinet. 20 PHoENIx CoNTACT Protection for transceiver systems GPS or GSM (900, 1800 MHz) UMTS - With N connector GPS or GSM (900, 1800 MHz) UMTS CN-UB-280DC-SB Order No. 2818148 CN-UB-280DC-BB Order No. 2818850 C7/16-UB-280DC-SB-SET Order No. 2881544 - With 7/16 connector GSM (900, 1800, 1900 MHz) UMTS CN-LAMBDA/4-2.25-BB Order No. 2801057 - Without supply voltage on the coaxial cable - Very low protection level - With N connector CN-LAMBDA/4-2.25-SB Order No. 2801056 GSM (900, 1800, 1900 MHz) UMTS C7/16-LAMBDA/4-2.25-BB Order No. 2801060 - Without supply voltage on the coaxial cable - Very low protection level - With 7/16 connector C7/16-LAMBDA/4-2.25-SB Order No. 2801059 WiMAX (2.4... 6 GHz) CN-LAMBDA/4-5.9-BB Order No. 2838490 - Without supply voltage on the coaxial cable - Very low protection level - With N connector CN-LAMBDA/4-5.9-SB Order No. 2800023 Accessories Mounting plate - For individually securing the CN-UB-280DC Mounting plate, 90° angled - For individually securing the CN-UB-280DC e.g. for wall mounting CN-UB/MP Order No. 2818135 CN-UB/MP-90DEG-50 Order No. 2803137 PHoENIx CoNTACT 21 Protection for video monitoring systems 50 Ohm C-UFB-5DC/E Order No. 2782300 75 Ohm C-UFB-5DC/E 75 Order No. 2763604 with BNC connection for one video signal PT 3-PB-ST Order No. 2858030 PT 1X2+F-BE Order No. 2856126 with screw connection for two video signals PT 2X2-HF-5DC-ST Order No. 2839567 PT 2X2-BE Order No. 2839208 SAT-MULTISWITCH Protection for television and radio systems SAT-MULTISWITCH Satellite television Upstream of the distributor (multiswitch) Satellite television P 125 Mo 21.05.- 17.23 DIGITALSAT-RECEIVER Upstream of the SAT receiver or television Cable/terrestrial television Power NDR NDR DR 2 1 2 3 4 5 6 7 8 9 Power Traack 1 Tra 12 2 03: 0 3:2 3: 24 Power prog Power Vol Vo olu ume: ume m : 23 23 ssou ource ce e: CD CD Phones Tuner Aux1 Aux2 Tape1 Tape2 CD Phono Upstream of the television, radio or tuner of the HiFi system C-SAT-BOX Order No. 2880561 C-TV-SAT Order No. 2856993 C-TV/HIFI Order No. 2857002 Accessories F connector adapter (plug-to-plug) - Ideal for direct connection of the C-SAT-BOX to a multiswitch with the same pitch - No thread plug-in coupling allows a quick connection ADAPTER KOAX TYP F Order No. 2880972 - Secure hold via clamping ring F connector cable (connector to connector) - For flexibly connecting the C-SAT-BOX to a multiswitch with a different pitch 22 PHoENIx CoNTACT KBL-SAT/20 Order No. 2880985 Combined protection for television/radio connections and the power supply unit Satellite television Country: D, A, NL Use with simultaneous protection of power supply upstream of the SAT receiver or television. MNT-TV-SAT D Order No. 2882284 MNT-TV-SAT D/WH Order No. 2882297 Country: B, F, CZ, SVK, PL MAINTRAB MNT-... MNT-TV-SAT B/F Order No. 2882307 Country: E, P MNT-TV-SAT E Order No. 2882310 Country: S, FIN, N MNT-TV-SAT S/WH Order No. 2880888 P 125 Mo 21.05.- 17.23 DIGITALSAT-RECEIVER COMBITRAB CBT-... Country: D, I, NL, E, P CBT-TV-SAT Order No. 2857303 Cable/terrestrial television Country: D, A, NL Use with simultaneous protection of power supply upstream of the television, radio or tuner of the HiFi system. MNT-TV-SAT D Order No. 2882284 MNT-TV-SAT D/WH Order No. 2882297 Country: B, F, CZ, SVK, PL MAINTRAB MNT-... MNT-TV-SAT B/F Order No. 2882307 Country: E, P MNT-TV-SAT E Order No. 2882310 Country: S, FIN, N MNT-TV-SAT S/WH Order No. 2880888 Power ND NDR DR R 2 1 2 3 4 5 6 7 8 9 Power Traack 1 Tra 12 2 03: 0 3:2 3: 24 Power prog Power Vol Vo olu ume: ume m : 23 23 ssou ource ce e: CD CD Phones Tuner Aux1 Aux2 Tape1 Tape2 CD Phono COMBITRAB CBT-... Country: D, I, NL, E, P CBT-TV-SAT Order No. 2857303 PHoENIx CoNTACT 23 Further information on the products presented here and on the world of solutions from Phoenix Contact can be found at www.phoenixcontact.net/catalog Modular Terminal Blocks CLIPLINE 1 Marking Systems, Tools, and Mounting Material CLIPLINE 2 Or contact us directly. Connection Technology for Field Devices and Field Cabling PLUSCON INTERFACE Automation Components and Systems AUTOMATION PHOENIX CONTACT GmbH & Co. KG 32823 Blomberg, Germany Phone: +49 (0) 52 35 3-00 Fax: +49 (0) 52 35 3-4 12 00 www.phoenixcontact.com Printed in Germany Signal Converters, Switching Devices, Power Supply Units MNR 52005654/10.04.2012-01 Power and Signal Quality TRABTECH © PHOENIX CONTACT 2012 Device Connection Technology and Electronic Housings COMBICON