Manual Direct05 Logic

Manual Direct5
View more...
   EMBED

Share

Preview only show first 6 pages with water mark for full document please download

Transcript

Programming Software User Manual PC-DSOFT5-M WARNING Thank you for purchasing automation equipment from Automationdirect.com®. We want your new automation equipment to operate safely. Anyone who installs or uses this equipment should read this publication (and any other relevant publications) before installing or operating the equipment. To minimize the risk of potential safety problems, you should follow all applicable local and national codes that regulate the installation and operation of your equipment. These codes vary from area to area and usually change with time. It is your responsibility to determine which codes should be followed, and to verify that the equipment, installation, and operation is in compliance with the latest revision of these codes. At a minimum, you should follow all applicable sections of the National Fire Code, National Electrical Code, and the codes of the National Electrical Manufacturer's Association (NEMA). There may be local regulatory or government offices that can also help determine which codes and standards are necessary for safe installation and operation. Equipment damage or serious injury to personnel can result from the failure to follow all applicable codes and standards. We do not guarantee the products described in this publication are suitable for your particular application, nor do we assume any responsibility for your product design, installation, or operation. Our products are not fault-tolerant and are not designed, manufactured or intended for use or resale as on-line control equipment in hazardous environments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons systems, in which the failure of the product could lead directly to death, personal injury, or severe physical or environmental damage ("High Risk Activities"). Automationdirect.com specifically disclaims any expressed or implied warranty of fitness for High Risk Activities. For additional warranty and safety information, see the Terms and Conditions section of our catalog. If you have any questions concerning the installation or operation of this equipment, or if you need additional information, please call us at 770-844-4200. This publication is based on information that was available at the time it was printed. At Automationdirect.com we constantly strive to improve our products and services, so we reserve the right to make changes to the products and/or publications at any time without notice and without any obligation. This publication may also discuss features that may not be available in certain revisions of the product. Trademarks This publication may contain references to products produced and/or offered by other companies. The product and company names may be trademarked and are the sole property of their respective owners. Automationdirect.com disclaims any proprietary interest in the marks and names of others. Copyright 2006, Automationdirect.com Incorporated All Rights Reserved No part of this manual shall be copied, reproduced, or transmitted in any way without the prior, written consent of Automationdirect.com Incorporated. Automationdirect.com retains the exclusive rights to all information included in this document. AVERTISSEMENT Nous vous remercions d'avoir acheté l'équipement d'automatisation de Automationdirect.comMC. Nous tenons à ce que votre nouvel équipement d'automatisation fonctionne en toute sécurité. Toute personne qui installe ou utilise cet équipement doit lire la présente publication (et toutes les autres publications pertinentes) avant de l'installer ou de l'utiliser. Afin de réduire au minimum le risque d'éventuels problèmes de sécurité, vous devez respecter tous les codes locaux et nationaux applicables régissant l'installation et le fonctionnement de votre équipement. Ces codes diffèrent d'une région à l'autre et, habituellement, évoluent au fil du temps. Il vous incombe de déterminer les codes à respecter et de vous assurer que l'équipement, l'installation et le fonctionnement sont conformes aux exigences de la version la plus récente de ces codes. Vous devez, à tout le moins, respecter toutes les sections applicables du Code national de prévention des incendies, du Code national de l'électricité et des codes de la National Electrical Manufacturer's Association (NEMA). Des organismes de réglementation ou des services gouvernementaux locaux peuvent également vous aider à déterminer les codes ainsi que les normes à respecter pour assurer une installation et un fonctionnement sûrs. L'omission de respecter la totalité des codes et des normes applicables peut entraîner des dommages à l'équipement ou causer de graves blessures au personnel. Nous ne garantissons pas que les produits décrits dans cette publication conviennent à votre application particulière et nous n'assumons aucune responsabilité à l'égard de la conception, de l'installation ou du fonctionnement de votre produit. Nos produits ne sont pas insensibles aux défaillances et ne sont ni conçus ni fabriqués pour l'utilisation ou la revente en tant qu'équipement de commande en ligne dans des environnements dangereux nécessitant une sécurité absolue, par exemple, l'exploitation d'installations nucléaires, les systèmes de navigation aérienne ou de communication, le contrôle de la circulation aérienne, les équipements de survie ou les systèmes d'armes, pour lesquels la défaillance du produit peut provoquer la mort, des blessures corporelles ou de graves dommages matériels ou environnementaux («activités à risque élevé»). La société Automationdirect.com nie toute garantie expresse ou implicite d'aptitude à l'emploi en ce qui a trait aux activités à risque élevé. Pour des renseignements additionnels touchant la garantie et la sécurité, veuillez consulter la section Modalités et conditions de notre documentation. Si vous avez des questions au sujet de l'installation ou du fonctionnement de cet équipement, ou encore si vous avez besoin de renseignements supplémentaires, n'hésitez pas à nous téléphoner au 770-844-4200. Cette publication s'appuie sur l'information qui était disponible au moment de l'impression. À la société Automationdirect.com, nous nous efforçons constamment d'améliorer nos produits et services. C'est pourquoi nous nous réservons le droit d'apporter des modifications aux produits ou aux publications en tout temps, sans préavis ni quelque obligation que ce soit. La présente publication peut aussi porter sur des caractéristiques susceptibles de ne pas être offertes dans certaines versions révisées du produit. Marques de commerce La présente publication peut contenir des références à des produits fabriqués ou offerts par d'autres entreprises. Les désignations des produits et des entreprises peuvent être des marques de commerce et appartiennent exclusivement à leurs propriétaires respectifs. Automationdirect.com nie tout intérêt dans les autres marques et désignations. Copyright 2006, Automationdirect.com Incorporated Tous droits réservés Nulle partie de ce manuel ne doit être copiée, reproduite ou transmise de quelque façon que ce soit sans le consentement préalable écrit de la société Automationdirect.com Incorporated. Automationdirect.com conserve les droits exclusifs à l'égard de tous les renseignements contenus dans le présent document. MANUAL REVISIONS Please include the Manual Number and the Manual Issue, both shown below, when communicating with Technical Support regarding this publication. Title: DirectSOFT 5 Programming Software User Manual Manual Number: Issue: Issue Date: PC-DSOFT5-M First Edition 3/06 Publication History Issue 1st Edition Date 3/06 Description of Changes Original issue TABLE OF CONTENTS Chapter 1: Introduction Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 The Purpose of this Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Who Can and Should Use DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Only One DirectSOFT 5 Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Supplemental Manuals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Menu Selections and Keystrokes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Key Topics for Each Chapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Chapter 2: Quick Start Getting to Know Windows . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Recommended System Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 DirectSOFT 5 Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 Installation of DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . . . . . .2-3 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8 Welcome to DirectSOFT 100 . . . . . . . . . . . . . . . . . . . . . . . .2-10 Begin Editing a Program . . . . . . . . . . . . . . . . . . . . . . . . . . .2-12 Table of Contents Establish the Communication Link . . . . . . . . . . . . . . . . . . .2-22 Connect the PC to the PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-22 1 Monitor the Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-28 2 Chapter 3: Managing Projects 3 Started Using DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . . .3-2 D Get Understanding the Launch Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 5 Create a New Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 6 New Enter the New Project Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 7 Importing Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 8 Program Documentation Mapping from TISOFT and Logicmaster . . . . . . .3-6 9 Copy or Save Existing DirectSOFT Files . . . . . . . . . . . . . . .3-7 1 Chapter 4: Programming Environment 11 Offline Toolbar Components . . . . . . . . . . . . . . . . . . . . . . . . .4-2 2 Offline Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-2 Online Toolbar Components . . . . . . . . . . . . . . . . . . . . . . . . .4-5 13 Online Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-5 4 Additional Toolbars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 The File Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 A The Edit Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 Search Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-9 B The The View Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10 C The Tools Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11 PLC Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-12 D The The PLC Diagnostics Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13 The PLC Setup Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-13 The PLC Setup Toolbar (cont’d) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-14 The Debug Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-15 ii DirectSOFT 5 User Manual, 1st Edition Table of Contents The Window Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-16 The Help Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-17 The Custom Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-17 PLC System Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-19 Communication/Link Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-20 PLC Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-20 Program Memory Usage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-20 PLC Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-20 Program Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-20 1 The Options Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-21 Ladder Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-22 Global Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-23 Colors in DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-24 Colors Conveying Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-25 Select New Colors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-26 The Default Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-26 Monochrome . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-26 Select a Theme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-27 The Tool Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-28 Be Familiar with the Ladder Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-28 The Split Screen Feature . . . . . . . . . . . . . . . . . . . . . . . . . . .4-30 Split Screen Bar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-30 The New Window Feature . . . . . . . . . . . . . . . . . . . . . . . . . .4-31 Chapter 5: Edit a Program I/O Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 Referencing Program Elements . . . . . . . . . . . . . . . . . . . . . .5-4 Data Types . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-4 Aliases . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5 Timer/Counter Current Values . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-5 Accessing I/O Points as Memory Locations . . . . . . . . . . . . . . . . . . . . . . . . .5-5 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition iii Table of Contents Entering Program Instructions . . . . . . . . . . . . . . . . . . . . . . .5-6 1 The Instruction Editor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-6 Using the Ladder Palette . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8 Opening the Instruction Browser . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-8 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Shortcuts for Entering Instructions . . . . . . . . . . . . . . . . . .5-11 Entering NO and NC Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-12 Entering Instructions in Parallel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-13 Entering Power Flow Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14 Entering Special Case Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-16 End Coil . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-17 Setting and Resetting a Bit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-18 Using Floating Point Math . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-18 Drawing/Deleting Connecting Lines . . . . . . . . . . . . . . . . . .5-19 Drawing the Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-19 Create Midline Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-20 Deleting Connecting Lines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-20 Selecting Rungs for Deleting, Cutting or Copying . . . . . .5-21 Deleting Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-22 Copying Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23 Cut and Paste Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-25 Merge (Combine) Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . .5-26 Inserting Columns, Rows and Rungs . . . . . . . . . . . . . . . . .5-27 Insert a Column to Add an Instruction . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-27 Insert a Row or Rung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-28 Using Search and Replace . . . . . . . . . . . . . . . . . . . . . . . . .5-29 Using the Object Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-29 The Search Range Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-30 The Document Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-30 The Object Table Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-30 Common Mistakes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 Failure to Enter the Edit Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 iv DirectSOFT 5 User Manual, 1st Edition Table of Contents AND above a Join . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 Forgetting to Select Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 1 Chapter 6: Documentation Turn Documentation On and Off . . . . . . . . . . . . . . . . . . . . . .6-2 The Options Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-2 Documentaion Selections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3 General Documentaion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-3 Using the Documentation Editor . . . . . . . . . . . . . . . . . . . . . .6-4 Using the Scroll Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-4 Copying Documentation Between Elements . . . . . . . . . . . . . . . . . . . . . . . .6-5 Documenting and Assigning Nicknames . . . . . . . . . . . . . . .6-6 Create an Unassigned Nickname . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6 Assign the Nickname to an Element . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-6 Entering Rung Comments . . . . . . . . . . . . . . . . . . . . . . . . . . .6-9 Comments are Free-form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-9 Selecting Rungs for Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-9 Using the Scroll Buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-10 Use the Editing Keys . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-10 Move Rung Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-11 Entering Stage Comments . . . . . . . . . . . . . . . . . . . . . . . . . .6-12 Use Stage View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-12 Comments are Free-form . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-13 Selecting Stages to Comment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-13 Editing the Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-13 Importing and Exporting . . . . . . . . . . . . . . . . . . . . . . . . . . .6-14 Exporting Program Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-14 Export Element Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-16 Export Rung Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-18 Importing a Program . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-19 Importing Element Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-22 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition v Table of Contents Importing Program Comments . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-24 1 Insert Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-24 Restore . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-27 2 Prevent Documentation Loss . . . . . . . . . . . . . . . . . . . . . . .6-28 Save Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-28 3 Backup Project . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-29 D Chapter 7: Other Views 5 Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2 6 Tabbed The Primary Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2 7 Stage (RLL ) View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4 8 Troubleshooting RLL vs. RLL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-4 Stage Components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-5 9 Mnemonic View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6 1 Handheld Progammer Aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6 Reference (XRef) View . . . . . . . . . . . . . . . . . . . . . . . .7-7 11 Cross XRef Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-7 2 Change the XRef Query . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-8 Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-9 13 XRef Usage Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10 4 Usage Mode Toolbar . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-10 XRef DB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-11 A PID View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12 B PID Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12 C Output Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-14 View Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-16 D PLUS PLUS Chapter 8: Printing Print the Current View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2 Print the Ladder View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-2 vi DirectSOFT 5 User Manual, 1st Edition Table of Contents Other Print Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-3 Print Multiple Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-5 Print View Common Setup . . . . . . . . . . . . . . . . . . . . . . . . . . .8-7 Using Print Preview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-8 Print Preview Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-8 Print Preview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-9 1 Print Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10 Parts of Program not Printed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10 Program Prints “Garbage” . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10 DirectSOFT 5 Crashes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-10 Print Setup Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-11 Chapter 9: Setup & Manage Communication Links Establish the Communication Link . . . . . . . . . . . . . . . . . . . .9-2 Setup a Serial Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-2 Link Status . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-6 Setup an Ethernet Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-7 Setup a Modem Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-12 Modem Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-12 Configuring the Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-16 Comm Link Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-20 Going on Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-22 Connect the PLC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-22 Use the Project Folder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-22 Use the Link . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-22 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D Chapter 10: Debugging and Monitoring Monitor with Data View . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-2 DirectSOFT 5 User Manual, 1st Edition vii Table of Contents Using Data View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-2 1 Open a New Data View Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-2 A Closer Look . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-3 Data View Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-4 Select Bits for Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-5 Data View Documentation Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-7 Apply Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-7 Data View Mode Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-8 Make Data View Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-8 Data Format and Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-10 Write the Edits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-11 Auto-increment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12 Editing Entries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-12 Save the Data View Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-13 Using Pause Bits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-14 Use Override Bits to Control I/O (DL05/06/240/250-1/260/350/450 Only) . . . . . . . . . . . . . . . . . . . . . . . . . .10-15 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Change Value Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-16 Use the Change Value Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-16 Specify an Element Reference or Nickname . . . . . . . . . . . . . . . . . . . . . .10-17 Enter a New Value . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-18 Using the Memory Editor . . . . . . . . . . . . . . . . . . . . . . . . . .10-20 Select the Locations to View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-20 Test Mode Operations for Debugging . . . . . . . . . . . . . . .10-22 Select Test Mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-22 Test Program Operations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-23 The Test Operations Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-24 Trap Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-25 Access the Trap Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-25 Use with Data View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-27 Stack Monitor (DL440 Only) . . . . . . . . . . . . . . . . . . . . . . . .10-28 Access the Stack Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-28 viii DirectSOFT 5 User Manual, 1st Edition Table of Contents Check DirectSOFT 5 File Revision . . . . . . . . . . . . . . . . . .10-29 Appendix A: Protocols and Cable Diagrams Cables and Protocols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-2 Programming Cable Diagrams . . . . . . . . . . . . . . . . . . . . . . .A-6 1 AppendixB: Communications Troubleshooting DS500.ini File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2 DS500.ini File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2 Enable Dump=1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-3 Enable AutoSense=0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-4 Startup Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-4 Other Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 USB-to-Serial Converters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 Microsoft ActiveSync . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition ix INTRODUCTION CHAPTER 1 In This Chapter Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Conventions Used . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Chapter 1: Introduction Introduction 1 The Purpose of this Manual This manual describes how to use the DirectSOFT 5 software for programming and monitoring any of the DirectLogic and compatible CPUs. This manual will not teach you how to develop a relay ladder logic (RLL) program or attempt to familiarize you with the instruction sets of the CPUs. Please refer to the applicable PLC user manual for the RLL instructions. The Quick Start chapter will show the first time user how to get started using DirectSOFT 5. The balance of the manual will detail all of the programming tools made available to the user. 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Who Can and Should Use DirectSOFT 5 If you have a PLC belonging to the DirectLOGIC CPU family, you can use DirectSOFT 5 to manage your existing ladder logic programs and to create new ones. The families of PLCs that currently exist under this description are shown below. DirectLOGIC PLC Family DL05 CPUs Two built-in ports Max. baud = 38.4 K DL06 CPUs Two built-in ports Max. baud = 38.4 K DL105 CPUs One built-in port Fixed baud = 9.6 K DL205 CPUs One built-in port D2-230; fixed baud = 9.6 K Two built-in ports D2-240; max. baud = 19.2 K Two built-in ports D2-250(-1)/260 max baud =38.4 K DL305 CPUs D3-330 requires D3-232-DCU; max. baud = 19.2 K Two built-in ports D3-340/350; max. baud = 38.4 K DL405 CPUs Two built-in ports D4-430/440; max baud = 19.2 K Four built-in ports D4-450; max. baud = 38.4 K 1-2 DirectSOFT 5 User Manual, 1st Edition Chapter 1: Introduction Besides being easy to use, DirectSOFT 5 includes the following features: • Dockable/Floating Views - includes Cross Reference, Data Views and Output window. • New look and feel - new toolbar button icons, new toolbars and completely configurable toolbars. • Tabbed main views (ladder, stage, documentation editor). • Online Status Bar is now integrated as part of the primary status bar on the bottom of the application. Also, each online status bar field is a “button” which will bring up an appropriate dialog (the mouse can be floated over each of the fields to show a tool-tip to show what it will do). • User Interface (UI) Themes allows you to give DirectSOFT 5 a certain UI feel (Office XP, Office 2003, Mac, et.al.). • Export Data View allows you to export the information in the Data View Element and Status columns in CSV (comma separated variable) format, for a minimal logging capability. • Intelligent Boxes (IBoxes) are modularized/parameterized blocks of ladder logic that perform common, simple, but also some complex PLC logic. These will only download to the PLCs with the proper firmware. 1 See the chart below for the PLCs and the supporting firmware revisions required for the new IBox instructions. PLC DL05 DL06 D2-250-1 D2-260 D4-450 Firmware 5.10 2.10 4.60 2.40 3.30 Only One DirectSOFT 5 Version There is only one DirectSOFT 5 version for the DirectLOGIC PLC family. All versions of DirectSOFT programming software (v1.0 v4.0) can be upgraded to version 5. Also, all programs created with older versions of DirectSOFT are compatible with DirectSOFT 5. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 1-3 Chapter 1: Introduction Supplemental Manuals 1 Depending on the products you have purchased, there may be other manuals that are necessary to use for your application. User Manuals • DL05 User Manual Ҁ D0-USER-M • DL06 User Manual Ҁ D0-06USER-M • DL105 User Manual Ҁ D1-USER-M • DL205 User Manual Ҁ D2-USER-M • DL305 User Manual Ҁ D3-USER-M • DL350 User Manual Ҁ D3-350-M • DL405 User Manual Ҁ D4-USER-M NOTE: AutomationDirect also has many associated product user manuals, such as analog manuals, which will assist you with your application. 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Technical Support We realize that even though we strive to do our best, we may have arranged our information in such a way that you cannot find what you are looking for. First, check these resources for help in locating the information: • Table of Contents – chapter and section listing of contents, in the front of this manual • Appendices – reference material for key topics, near the end of this manual • Index – reference for key items You can also check our online resources for the latest product support information: • Internet – the address of our website is: http://www.automationdirect.com If you still need assistance, please call us at 770–844–4200. Our technical support team will be available to work with you to answer your questions. They are available Monday through Friday from 9:00 A.M. to 6:00 P.M. Eastern Standard Time. If you have a comment or question about any of our products, services, or manuals, please fill out and return the ‘Suggestions’ card that was shipped with this manual. 1-4 DirectSOFT 5 User Manual, 1st Edition Chapter 1: Introduction Conventions Used When the “notepad” symbol is shown in the left-hand margin, the paragraph to its immediate right will be a special note. The word NOTE: in boldface will mark the beginning of the text. 1 When the “exclamation mark” symbol is shown in the left-hand margin, the paragraph to its immediate right will be a warning. This information could prevent injury, loss of property, or even death (in extreme cases). The word WARNING: in boldface will mark the beginning of the text. Whenever the “lightbulb” is shown in the left-hand margin, the paragraph to its immediate right will provide a special tip. The word TIP: in boldface will mark the beginning of the text. Menu Selections and Keystrokes When the software requires you to use a particular keystroke or menu selection, the written instructions will be in boldface type. Combination keystrokes will be separated with a plus (+) sign. For example, Ctrl + C means: Hold down the Ctrl key and press the C key. Menu selections can also be combinations and separated by a greater-than sign. For example, File > Write Program > to Disk is a menu selection combination. Key Topics for Each Chapter The beginning of each chapter will list the key topics that can be found in that chapter. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 1-5 CHAPTER QUICK START 2 In This Chapter: Getting to Know Windows . . . . . . . . . . . . . . . . . . . . . . .2-2 Installation of DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . .2-3 Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8 Welcome to DirectSOFT100 . . . . . . . . . . . . . . . . . . .2-10 Begin Editing a Program . . . . . . . . . . . . . . . . . . . . . . .2-12 Establish the Communication Link . . . . . . . . . . . . . . .2-22 Monitor the Program . . . . . . . . . . . . . . . . . . . . . . . . . .2-28 Quick Start Getting to Know Windows 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D DirectSOFT 5 Programming Software runs under 32-bit Windows operating systems (98/2000/NT/XP). It’s a good idea to understand the operating system for your computer. Recommended System Requirements Check the following system requirements when choosing your PC configuration. • Pentium/Celeron CPU, 1 Ghz or greater • Windows 98/2000/XP (Home and Pro) NO DOS, OS/2, Macintosh, Linux or Unix versions or 16 bit versions • 512Mb RAM • 20Mb available hard drive disk space, 33 Mb for a complete installation. • CD-ROM or DVD drive • At least one unused serial communications port, USB with USB-to-serial adapter, 10base-T or 10/100 Eternet Network card • 1024 x 768 resolution color SVGA monitor Power Supply It is recommended that the computer which DirectSOFT 5 operates on has some form of power surge protection. A quality surge protector will protect your computer from most surges and spikes; however, an uninterruptible power supply (UPS) will provide the best protection. A UPS provides isolation between the AC power source and the computer. It also has a battery backup for blackout and brownout conditions. DirectSOFT 5 Package Contents Now is the time to review the contents of your DirectSOFT 5 software package. you should have the following items: • CD ROM • Programming User Manual 2-2 DirectSOFT 5 User Manual, 1st Edition Quick Start Installation of DirectSOFT 5 Step 1: Load the CD DirectSOFT 5 for PLCs Server Software is available on the AutomationDirect Product Showcase CD. To install DirectSOFT 5, insert the AutomationDirect CD into your PC’s CD drive. The CD should start automatically and open the “Install Software” window shown below. Note: If the DirectSOFT 5 CD does not start automatically, go to the Windows START button, select RUN and type: E:\ADC_catalog.exe Change the letter E above to match your CD drive. Then click on OK and the program will start. 1 Step 2: Select the Install Software Option The DirectSOFT 5 “Install Software” window offers all the options available with this CD. To install DirectSOFT 5, select the Install Purchased Software option indicated on the figure above. The following message dialog will appear. This dialog issues a reminder to exit all other Window applications. If you are unsure of the programs that may be running, open the Task Manager by pressing the Ctrl-ALT-Delete keys at the same time. Close any opened applications by selecting them and clicking on the Close button of the Task Manager. Click on the Next button to proceed with the installation. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-3 Quick Start Step 3: Enter the Product Key Code 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D From this window, enter the Product Key that was e-mailed to you, or phone 1-800-633-0405 and get the Product Key from either sales or technical support if you did not receive it. This software package is protected by this Product Key code. Only licensed users that have a Product Key code may install the software. After entering the Product Key click the Next button. Enter Product Key here Then click on the Next button Step 4: Installing an Upgrade If you are installing the DirectSOFT 5 upgrade version, setup will search your PC to look for a previous version of DirectSOFT. If a previous DirectSOFT version is not found, you will be prompted to enter a valid product key code from a previous version of DirectSOFT. Click here to proceed with the DirectSOFT 5 installation 2-4 DirectSOFT 5 User Manual, 1st Edition Quick Start Step 5: License Agreement The wizard displays the “Software License Agreement” shown below. Read the agreement and select I accept the terms of the license agreement. Click Next to continue with the installation. If you do not accept the license agreement, cancel the installation. 1 Click here if you agree with the License Agreement’s terms. Step 6: Enter the Customer Information The “Customer Info” window requests the user name and company. Enter the name of the person assigned to the DirectSOFT 5 Programming Software and the name of your company. Click the Next button to continue with the DirectSOFT 5 installation. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-5 Quick Start Step 7: Select the Type of Installation 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D The wizard now displays the “Setup Type” window. This window allows you to select either the “Complete” or the “Custom” type of installation. Complete is the most common selection. Custom allows you to select the optional components you want. It is recommended that you select Complete for your DirectSOFT 5 installation. Click on the Next button to proceed with installation. Step 8: Ready to Install The wizard continues with the “Ready to Install the Program” window appears. Verify the folder name where the DirectSOFT 5 files are to be stored. If this is the desired folder, click on the Next button to continue with the installation. 2-6 DirectSOFT 5 User Manual, 1st Edition Quick Start The following window lets you know that the DirectSOFT 5 Programming Software is being installed onto your computer. 1 Step 9: Installation is Complete The wizard now displays the “InstallShield Wizard Complete” window shown below. Click on the Finish button. If an Upgrade If an older DirectSOFT version is found during the installation, you will be prompted to make DirectSOFT 5 the default projects folder. You will then be asked if you want the existing projects copied to the DirectSOFT 5 projects folder. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-7 Quick Start Getting Started 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Before beginning to edit a program, you need to open DirectSOFT 5. If you are already familiar with DirectSOFT, click on the DirectSOFT 5 icon located on your desktop screen to open the DSLaunch window. You can also click on Start located in the left-hand corner of the computer monitor. Now select Programs, find DirectSOFT 5, then select DSLAUNCH 5 in the drop-down window. The following DSLAUNCH window will appear. Windows-type Menu Tree Utilities, such as NetEdit Installed Support Communication Links to PLCs From this window, additional utilities, such as, NetEdit, CTRIO WB, etc., can all be launched from one central location. This is also used to create and manage PLC programs and the communications links between your personal computer and the PLC. Notice the different areas which are pointed out in the launch window. NOTE: Also see DSLAUNCH comments in Chapter 3. 2-8 DirectSOFT 5 User Manual, 1st Edition Quick Start If you have been using previous versions of DirectSOFT Programming Software, you will see that the DSLaunch window looks much like it always has. Differences are noted in the below descriptions: • Applications ȕ These are the applications currently installed in DirectSOFT5. They are visible in the Menu tree under the Applications folder/icon and are linked to applications that have been designed for launch from DirectSOFT 5. For example, to create a new program, double-click the DirectSOFT 5 Programming name. • Utilities ȕ Several utilities are available under this folder/icon. If you have already installed available utilities, such as, NetEdit, CTRIO Workbench, etc., these will be shown here. You will notice that there are three new utilities available, a shortcut to Microsoft® Calculator that comes with Microsoft® Windows, a direct link to the AutomationDirect website and a direct link to the Host Engineering website. Shortcuts to your favorite utilities can also be added by adding them to the Utililities section of the DS500.ini file. • Projects ȕ These are the programs which are created in DirectSOFT 5. A project is the collective name for your program and all of its documentation. When you create a new project or work on an existing project, you will see it listed in the Menu Tree under the Projects folder/icon by name. To open an existing project, double-click on the project name. To open a project not listed, right-click on Projects and select Browse to locate the project, then select it. • Comm Links ȕ This is for the communication links used to connect from your PC to one or more of your PLCs. If there were Comm Links existing in your previous version of DirectSOFT, they will appear here. New Comm Links will also appear here after they are setup. The remainder of this chapter will be devoted to the following: 1. Create a new program. 2. Add some rungs. 3. Document the elements and rungs. 4. Connect to a PLC. 5. Download to a PLC. 6. Monitor the program and change status. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-9 Quick Start Welcome to DirectSOFT100 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D NOTE: If you have purchased the full version of DirectSOFT 5, go to page 2-12, Begin Editing a Program. If you have loaded the free version of DirectSOFT 5, you should know what you can and cannot do with the software. What is DirectSOFT100? The DirectSOFT100 software is provided as a solution for small applications and to assist in your decision to purchase the full DirectSOFT 5 programming software. There are, of course, limitations to the use of DirectSOFT100. The following is what you can and cannot do with the software: • You CAN create a program from scratch, and it can be as large as you want it to be. • You CAN save programs larger than 100 words to disk, but you CANNOT write it to the PLC. • You CAN convert DirectSOFT100 version to the full version if you purchase the key and enter the key code in the DirectSOFT100 dialog (it may appear often) or in the Help > About dialog. • You CANNOT download a program to a PLC larger than 100 words. • You CANNOT open an offline project larger than 100 words. • You CANNOT open a program in the PLC larger than 100 words. There are no other limitations. DirectSOFT100 is able to use all of the features described in this manual. Many instances of DirectSOFT100 can be running at one time and monitor any number of data points. DirectSOFT100 is basically the same, functionally, as DirectSOFT 5 (full version) except the ladder program needs to remain within 100 words. 2-10 DirectSOFT 5 User Manual, 1st Edition Quick Start Using DirectSOFT100? To begin a project, double-click on DirectSOFT 5 Programming under Applications on the menu tree. The following Welcome to DirectSOFT100 window will appear. Click here to begin a project. 1 Click on Run DirectSOFT100 and the New Project dialog will open as shown on page 2-12. You can now begin to edit a program following from Step 1. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-11 Quick Start Begin Editing a Program 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D You can now begin editing your program. The following steps will show you the basics of editing with DirectSOFT 5. This will not be an attempt to teach you how to develop a control program, but it will give you the basics to get started using DirectSOFT 5 so that you can edit a program. Step 1: Start a New Project To begin a new project, double-click DirectSOFT 5 Programming under Applications in the menu tree. The following window will appear. The New Project window is used to enter the basic information to begin a new project. Name the new project, then move the cursor to the Family area and select the PLC family to match the PLC that you are using. Next, select the CPU type. Once all of the information has been entered, click on OK. Keep in mind that the available mnemonics, processing rules and the tool bar characteristics are tailored to the Family and Type selections that you make. Use this to start a new project or to open an existing project. New Project window Type a new name Select the PLC Family ...click on OK Select the CPU Type 2-12 DirectSOFT 5 User Manual, 1st Edition Quick Start After clicking on OK, the next window to appear is the Ladder View with a Tip of the Day dialog box as seen below. The Tip of the Day dialog will appear each time a new project is started, and each time an existing project is opened. If it is not desired to have this dialog “pop-up” as mentioned, simply click off the check mark preceding “Show tips at startup”. The tips dialog can always be opened by clicking on Help > Tip of the day on the main menu bar. More tips can be read by clicking on the Next button. After clicking on the Close button the new Program display window will be totally in view. 1 Show tips at startup Regular users of DirectSOFT will note that the new programming window looks a bit different than previous DirectSOFT programming software (see diagram on the next page). This is the default look whenever a new project is started. The “Online” and “Offline” toolbars have the same layout as previous DirectSOFT programming windows but a new look for the button icons. Notice that some of the toolbar icons are grayed-out and some of the icons are not. The available icons in the online toolbar will be visible. As a program is edited, more of the grayed-out icons will become visible. The online toolbar is grayed-out and will remain this way until the PC is connected to the PLC. See Chapter 4 for more toolbar features. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-13 Quick Start Offline Toolbar 1 Push-pin Online Toolbar Cursor 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Edit Mode buttons Ladder Palette Bar Drag bar By default, there are two windows that will be in view when a new project is opened. One is the Cross Reference View on the left and the other is the Ladder View on the right. The Cross Reference View is one of the new dockable views in DirectSOFT 5 which also includes Data Views and the Output window. These views can be docked to any edge of the Programming Window or they can be undocked and “float” to any part of the screen, even onto a different display if you have multiple monitors. If the view is docked, you can “auto-hide” the view by clicking on the push-pin in the upper righthand corner of the view. The view will auto-hide to the left of the Ladder View with the name of the view on the tab. To bring the view from auto-hide, hold the mouse cursor over the name in the tab. If the view is not needed, click on the X located to the right of the push-pin to close the view. See Chapter 7 to learn more about views. Notice the Ladder Palette Bar located to the right of the Ladder View. The element buttons are grayed-out unless the Edit Mode has been activated. To activate the Ladder Palette, click on either EDIT Mode button; one is located on the Offline toolbar and one is located at the top of the Ladder Palette. This palette can be repositioned anywhere on the screen by “grabbing” it with the mouse pointer at the top of the palette and dragging it to a new position. The Ladder Palette contains the buttons that access the rung elements and operations commonly used when editing ladder logic programs. 2-14 DirectSOFT 5 User Manual, 1st Edition Quick Start The diagram below shows a newly opened Display window with the Cross Reference View in the auto-hide position and the Ladder View in full view. 1 Cross Reference View in auto-hide position It is good practice to leave the Cross Reference View open while editing your program. The rung elements are added to the Cross Reference View as the program is accepted. Accepting a program will be discussed later in this chapter. NOTE: The Cross Reference View can be retrieved by going to View on the Menu Bar and select it from the drop-down menu, then click on the push-pin to keep it in view. Step 2: Select Edit Mode The ladder View has two viewing modes; the Display Mode and the Edit Mode. When a new program or an existing program is opened, the Ladder View will be in the Display Mode which is only a viewing mode. A program cannot be edited in this mode. In order to edit a program, you must be in the Edit Mode. To enable the Edit Mode, either click on the Edit Mode button on the Offline toolbar or click on the Edit Mode button on the Ladder Palette Bar. You will know when the Edit Mode is active when the cursor box becomes solid, a box appears around the Edit Mode buttons and the elements in the Ladder Palette are highlighted. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-15 Quick Start 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Edit Mode (solid cursor box) The Ladder Palette shown facing page may not be exactly like the one you have on your computer screen. The elements shown in the palette will depend on which CPU your PLC is using. This example shows the elements common to all the CPUs. Toolbar Options Edit Mode Normally Open Contact Normally Open Immediate Contact Positive Differential Contact Equal to Contact Equal to or Greater Than Contact Browse Contacts Browse Boxes Wire to Output Close view Accept Normally Closed Contact Normally Closed Immediate Contact Negative Differential Contact Not Equal to Contact Less Than Contact Browse Coils Browse Elements Wrap Wire to Stage 2-16 DirectSOFT 5 User Manual, 1st Edition Quick Start Step 3: Enter an Input Element Use the Ladder Palette to enter the first instruction of the program. First, click on one of the Edit Mode buttons to begin to edit your program. The rectangular edit cursor will change to a solid color. The edit cursor should be positioned to the far left on Rung 1. Your first entry can be placed here, normally a relay contact or an element. Click on the Normally Open Contact symbol on the palette. The cursor will change to a box with an open relay contact, a window with the text cursor blinking at the end of address C0 (highlighted) and green, valid entry, indicators. Enter the contact Delete the edit box Default address Open the Element Browser Valid entry indicators 1 If the green dot changes to red, it means that the address is incorrect, not valid or a wrong character. For example, if you typed the letter “O” instead of the digit “0”, the indicator would turn red and stay red until you correct the mistake. For this example, enter X0 over C0. The valid entry indicator should be green meaning the address is correct. Now, either click on the check mark (ͱ) or press the Enter key. Enter X0 Notice the Valid entry indicator will be green when a valid contact address is entered 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-17 Quick Start The element will be entered and the coursor will move to the next entry position. A yellow vertical bar will appear to the left of the left of Rung 1. Since this is not a color manual, a light colored vertical bar is seen in the example. The yellow bar indicates that an instruction (or instructions) has been entered, but the program has not been accepted (compiled). 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Yellow colored bar indicates the rung has not been accepted. Step 4: Enter an Output Element Now, move the cursor to the end of the rung, positioned over the NOP. Click on the Browse Coils button on the Ladder Palette. The Instruction Browser will appear with the Standard Coil selected as the default. Click OK to enter the standard coil. Keep in mind that one of the other output coils could have been selected. 2-18 DirectSOFT 5 User Manual, 1st Edition Quick Start The Instruction Browser will be replaced with the element entry box. The default address, C0, will be highlighted. Enter Y0 and notice the valid entry indicator is green for a proper entry. Either click on the (ͱ) or press the Enter key to enter the output coil. Enter Y0 here 1 Rung 1 has now been programmed. This rung can be downloaded to the PLC except for one missing rung. All programs must be terminated with an END Coil rung. Step 5: Enter the End Rung To program this rung, position the cursor so it is over the NOP at the end of Rung 2, and click on the Browse Coils button. The Instruction Browser will appear as shown in the diagram below. This time, select Program Control located in the Coil Class selection window. Next, select END located in the Coils selection window. Click on OK, then Enter. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-19 Quick Start The below diagram shows the two rungs that have been programmed. This is a basic program that can be downloaded to your PLC. Additional rungs can be programmed, but you can go ahead and accept the program 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Step 6: Accepting and Saving the Program The program now needs to be accepted in order to be downloaded to the PLC. As noted in the above diagram, there are two Accept buttons. Click on either Accept button to compile the program. Once the rungs are accepted with no errors, the yellow bar will change to green, the Accept buttons will be grayed-out and the Cross Reference View now shows the two elements that have been programmed. Read and Write buttons Programmed elements now appear in the Cross Reference View Green bar indicates the rung has been accepted. 2-20 DirectSOFT 5 User Manual, 1st Edition Quick Start Notice that the two Read and Write buttons located to the left of the Offline toolbar are enabled and no longer grayed-out. The program can now be saved to the PC’s disk. To write the program to disk, click on the Write button. It is not necessary to save the program in order to download the program to the PLC, however, it is good practice to save your work as you edit a program. A mistake may be made at times and you may want to restore the program to the state that it was before the mistake was made. If a mistake is made and you want to restore the program, click on the Read button. This will refresh the screen with the previously saved version of your program. NOTE: When the program is saved by clicking on the Write (only to disk), the ladder program is all that is saved. Once you have edited a program and have included total documentaion, you will want to save all that you have done. This is accomplished by selecting File > Save Project > to disk. You can also click on Backup to accomplish the same thing with the addition of a Backup file. For more detail about documenting and saving the project refer to Chapter 6. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-21 Quick Start Establish the Communication Link 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D In order to download a program to the PLC a communication link must be established. This section will step you through the procedure for setting up the serial port of your PC. Refer to Chapter 9 if you need to create a serial link for a modem, or an Ethernet link. The following procedure will step you through the process of connecting the example program to a PLC. Connect the PC to the PLC Connect the programming cable from the serial port of the PC to the serial port of the PLC. Turn on your PLC and be sure that the RUN\TERM\STOP switch on the PLC is in the TERM position. Now, click on PLC on the Menu Bar, then select Connect from the dropdown menu and the Select Link dialog will appear. Since there isn’t a link to chose, click on Add. Step 1: Select the Port The following Link Wizard dialog will appear showing a list of communication ports. Select the port you will use (commonly COM1) and click Next. 2-22 DirectSOFT 5 User Manual, 1st Edition Quick Start Step 2: Select the PLC The next window will show a list of PLC Families. Select the PLC family by clicking on the appropriate choice. If you are unsure of the PLC family but know which communications protocol to use, select “Not Sure”. If you are using a DirectLOGIC compatible PLC, the Link Wizard will try and detect the PLC type automatically. Click Next when you are finished. 1 Step 3: Choose the Protocol and Node Address In this step, you will see a choice of either DirectNET or KSequence. Assuming you have selected the DirectLOGIC PLC family (not the DL305), the default, K-Sequence, will be highlighted. The K-Sequence protocol allows you to perform write operations to individual discrete I/O points and control relays. DirectNET protocol cannot write to individual bit locations. (See Appendix A for a list of protocols available for DirectLOGIC and compatible PLCs). If your PLC has been configured with a node address other than 1, enter that address now. Click Next when finished. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-23 Quick Start Step 4: Name the Link 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D If the Link Wizard is successful in communicating with the PLC, the following window will prompt you to enter a unique link name, and a description of the link if desired. The description field allows 32 characters. Enter the name for the link and description then click Finish and the Select Link dialog will appear with the link name listed. Since the link that was just created is the only one named in the dialog, click on Select to initiate connecting to the PLC. 2-24 DirectSOFT 5 User Manual, 1st Edition Quick Start DirectSOFT 5 automatically compares the currently open program with the program stored in the PLC. The following Online/Offline Differences dialog box will appear. This dialog asks which copy of 1 the ladder logic program is to be viewed, the copy in the PLC or the copy on the PC. Since we are dealing with a new program, select the Use Disk button. The Use Disk button is used whenever you have made a change to a program in the PC.and you are going online to load it into the PLC. If the Details button is pressed, a side-by-side comparison of the program in the PLC and the program on the PC will appear, such as the Compare Programs dialog seen below. The program selection can also be made from this dialog. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-25 Quick Start After clicking on the Use Disk button, the programming window will look a bit different. Notice that the icon buttons in the Online Toolbar are no longer grayed-out. The indicators at the bottom of the window tell you that the PLC is okay, the PC is online with the PLC and the PLC is in Program Mode. At this point the program has not been written to the PLC. You will also notice the two left most buttons on the Online toolbar (ReadP and WriteP) are highlighted. To write the program to the PLC, select WriteP. A pop-up indicator will appear to let you know that the program is being written to the PLC. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D After the program has been written to the PLC, all that needs to be done is to place the PLC in the RUN Mode. Click on the Mode button on the Online toolbar. This will bring the PLC Modes dialog window into view. Click on Run, then OK and the PLC will be in the RUN Mode. 2-26 DirectSOFT 5 User Manual, 1st Edition Quick Start Notice the green indicator at the bottom of the Ladder View. It shows the PLC is now in the Run Mode. How do you know that your program works? The best way is to monitor the program while the PLC is online. 1 Green indicating Run Mode 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-27 Quick Start Monitor the Program 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D There are many things that can be monitored in the relay ladder program by simply clicking on the Status button on the online toolbar. The monitor mode can be turned On and Off by clicking on the status button. When in the status mode, the element background will change to blue (by default) to indicate power flow when the input element is turned on. If there is power flow, the output background will also change color. Background color to indicate power flow (I/O On). The program editing and testing is now complete. The example program is the most simple program that can be written. You can add to this program by deleting the END rung (Rung 2) and continuing to edit additional rungs. Do not forget to end your program with an END rung. 2-28 DirectSOFT 5 User Manual, 1st Edition Quick Start The following picture is an example of how you might continue with your program. Note the Cross Reference View and the Data View. Chapters 9 and 10 will explain how to use these views. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 2-29 MANAGING PROJECTS CHAPTER 3 In This Chapter Get Started Using DirectSOFT 5 . . . . . . . . . . . . . . . . .3-2 Create a New Project . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Importing Projects . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 Copy or Save Existing DirectSOFT Files . . . . . . . . . . .3-7 Chapter 3: Managing Projects Get Started Using DirectSOFT 5 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D To open DirectSOFT 5, double-click on the DirectSOFT 5 icon which was installed on your desktop screen during the installation of the software. You can also click on Start located in the left-hand corner of the computer monitor. Once you do this, select Programs, find DirectSOFT 5, then select DSLaunch 5 in the drop-down window. The DSLaunch window, shown below, will appear. The DSLaunch window displays all of the applications and PLCs that DirectSOFT 5 supports. Understanding the Launch Window DirectSOFT 5 Programming Software is much more than a PLC programming package. With the Launch Window concept, utilities, such as, NetEdit, CTRIO WB, etc., can all be launched from one central location. The Launch Window is also used to create and manage PLC projects and the communication links between your personal computer and the PLC. Notice the different areas in the Launch Window. There is a menu tree very similar to what is in Windows Explorer. All that you see in the menu tree can be accessed from the tree. Windows-type Menu Tree Utilities, such as NetEdit Installed Support Communication Links to PLCs 3-2 DirectSOFT 5 User Manual, 1st Edition Chapter 3: Managing Projects The menu tree has four folder/icons which are: • Applications Ҁ These are the applications currently installed in DirectSOFT 5. The only installed application available is DirectSOFT 5 Programming. This is the point where you start a new project. • Utilities Ҁ Several utilities are installed here such as, ERM Workbench, CTRIO Workbench and NetEdit. They are installed automatically when DirectSOFT 5 is installed. • Projects Ҁ This folder/icon will contain the projects which are created in DirectSOFT 5. A project is the collective name for your ladder logic program and all of the documentation associated with it. Newly created projects and existing projects will reside here. As projects are created, they are added to the end of the list. • Comm Links Ҁ This folder/icon will contain the communication links between the personal computer and the different PLCs that you have (See Chapter 9). 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 3-3 Chapter 3: Managing Projects Create a New Project New Program 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D To create a new program, double-click on DirectSOFT 5 Programming in the Applications folder on the DSLaunch menu tree. Double-click here to start a new program Enter the New Project Information The New Project dialog box is used to define several things. • New Project Name Ҁ enter a name for your project (up to 32 characters - no extension). • Family Ҁ select the DirectLOGIC PLC family (or compatible) you will be using. • Type Ҁ select the CPU you are using from the available list. Remember, different PLCs use similar instructions, but they are still different in some ways. For this reason, it is extremely important that you specify the correct CPU. • Browse Ҁ you can keep the default project path, c:\DirectSOFT5\projects, or use the Browse button to either select a project not shown on the menu tree or a different folder with the project listed in it. 3-4 DirectSOFT 5 User Manual, 1st Edition Chapter 3: Managing Projects Importing Projects You may already have TISOFT or Logicmaster programs stored on your PC’s hard drive or on a disk. You may also have projects that were exported from DirectSOFT version 4. Use the following procedure to import these programs. 1. Open the New Project dialog as described on the previous page. 2. When the New Project dialog appears, click on the Cancel button. The programming window will remain on the screen. 3. Click on File on the toolbar, then select Import > Program. The Import Program dialog will appear as shown below. 4 Locate the program to be imported by selecting Look in:, then the location of the program, such as, on a diskette in the PC’s drive A:. 5. Select the Files of type: to choose the correct file, such as, TIsoft (*.vpu). 6. Select the program to be imported (up to 32 characters with no extension) from the diskette or other media where the program is found. The file name should appear in File name: area. 7. Either enter a name for the project in the New Project: area or use the Browse button to select the name from a location of your choice to store the project. 8. Click on the Open button to start the import process. An indicator window will appear to let you know that the program is being imported. After the program has been imported, it will appear as a normal DirectSOFT 5 program. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 3-5 Chapter 3: Managing Projects Program Documentation Mapping from TISOFT and Logicmaster Although most of the documentation will have a counterpart in 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D DirectSOFT 5 some of the documentation will not. The following table shows what is imported, what is not and the DirectSOFT 5 counterparts. TISOFT Source Documentaion Title Page Synonyms Comments (tied to output coil) Descriptions DirectSOFT 5 Documentation Title Page Editor Element Description Rung Comments (tied to rung) No Match Logicmaster Source Documentaion Nicknames Names Comments Coil Labels DirectSOFT 5 Documentation Nicknames Description Comments No Match 3-6 DirectSOFT 5 User Manual, 1st Edition Chapter 3: Managing Projects Copy or Save Existing DirectSOFT Files The question often arises as to what is needed when copying existing DirectSOFT files to a different memory area or directory using the DOS command line syntax or any type of file manager. If you are a first time user of DirectSOFT 5 and have no existing files to transfer, then you may skip this page and read it later. By default, projects are stored originally in the Projects subdirectory, however, they can reside in areas other than the default projects subdirectory. It really does not matter where they are storedҀthe method for copying or saving these existing files to another area is the same in each case. If you look where the projects have been stored, you will notice the main file for the project will always have a .prj extension after its root filename, but there are other files with the same root filename. This can be a little confusing to new users. This is due to the fact that DirectSOFT 5 performs a filename creation behind the scenes, and you don't get involved with the initial storage except to indicate the root filename and directory path. A frequently asked question is "which of these files do I need when making the storage transfer?". Copying or saving the filename.prj will be insufficient to truly transfer the total project. Not all of the files are necessary to recreate the program, but if you eliminate any of them, you may lose some important documentation and indexing information. The table shown on the following page lists the different file extensions and what they contain. The safest choice is to save or copy all files for a project having the same root filename, regardless of the different file extensions (see the table on the next page). 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 3-7 Chapter 3: Managing Projects DirectSOFT 5 Project Files File Extension Contents Data views are not associated with one single project, but can be shared among multiple projects DV1000 setup Element documentation (nickname, wiring information, description) Index file for the element documentation Project information Ladder rung comments Index file for the ladder rung comments Connects rung comments to correct rung no. Online only: connects to correct rung number (temporary until saved offline to *.lda PID documentation Contains the ladder program Print settings 305 R-memory data 305 R-memory editor format Stage comments Index file for stage comments PLC parameters, I/O configuration, pause bits V-memory data V-memory editor format Position of program windows, colors, etc. Docking pane layouts 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D dataviewname.dta filename.dv filename.esd filename.esx filename.inf filename.lcd filename.lcx filename.lda filename.ldo filename.pid filename.prj filename.prt filename.rd filename.rf filename.scd filename.scx filename.tls filename.vd filename.vf filename.wsp filename.xml Files Associated with DirectSOFT 5 Project Files File Extension importexport doc.namename.csv ctrioworkbenchname.cwb ermworkbenchname.erm importexportmnemonicname.txt Contents Comma Separated Variable Counter I/O configuration Ethernet remote master configuration Text file 3-8 DirectSOFT 5 User Manual, 1st Edition PROGRAMMING ENVIRONMENT CHAPTER 4 In This Chapter Offline Toolbar Components . . . . . . . . . . . . . . . . . . . . .4-2 Online Toolbar Components . . . . . . . . . . . . . . . . . . . . .4-5 Additional Toolbars . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 The Options Dialog . . . . . . . . . . . . . . . . . . . . . . . . . . .4-21 Colors in DirectSOFT 5 . . . . . . . . . . . . . . . . . . . . . . .4-24 The Split Screen Feature . . . . . . . . . . . . . . . . . . . . . .4-30 The New Window Feature . . . . . . . . . . . . . . . . . . . . . .4-31 Chapter 4: Programming Environment Offline Toolbar Components 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Once the Program Window has been opened, the Online and Offline toolbars are in view. The diagram below shows the default location of the Online and Offline Toolbars whenever a new program is started. The grayed-out icon buttons become highlighted as the program is being edited. Along with the toolbar icon buttons, the button functions are also available from the menu bar located at the top of the program window. The grayed-out Online toolbar will become available once the PC is online with the PLC. The toolbars Menu bar Online Toolbar Offline Toolbar are movable, or floating. By selecting the toolbar and dragging it with the mouse, the toolbar can be located wherever the programmer wishes to place it on the desktop. Offline Toolbar Read from Disk This button is used to retrieve and open a project from a disk, (i.e. HD or floppy). The program will appear in the Ladder View. Write to Disk The ladder logic program will be saved to the .prj project file on disk (not the entire project). It is a good practice to save your work frequently. This helps prevent data losses in the event of a system problem, such as a power failure. New Program This button will begin a new program offline. This button can be used with a project already open. The project will not be overwritten with the new project. You will be prompted to save the project before a new Ladder View will appear. Open a Project This will open an existing project. A project can be open when an existing project is already open. You will first be prompted to save your project, then the project that has been selected will be opened. 4-2 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Backup to File Click on this button to make a backup copy of your project. Edit a Program This button will turn on the Edit Mode. When the ladder view is in Edit Mode, the edit cursor will be a solid block on the screen. Click the Edit Mode button again to toggle back to Display Mode. Accept the Program Before the edited program can be downloaded to the PLC, the Accept button must be pressed. Once this is done, the program will be compiled; in other words, the program is put into a form that can be downloaded to the PLC. Cut This button is available in the Edit Mode. It allows the programmer to delete a marked, or selected, rung from the program and place it on the clipboard. Copy This button allows the programmer to copy one or more marked, or selected, program rungs to the clipboard (see page 5-21). Paste Whenever rungs are cut or copied, they are stored on a clipboard. Position the cursor where you want the rungs to go, then use this button to paste the rungs currently on the clipboard to the new location. Find This button is used to locate an element within a program. The element can be selected with the cursor before using the button or click on the button and enter the element to be found. Next Using this button will find the next occurrence of the element specified when the Find button has been used. Browse for an Element This button provides a quick overview of valid element ranges and nicknames for the current content as well as a convenient way to document an element. 1 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-3 Chapter 4: Programming Environment Display the Options Dialog Using this button will display the Options Dialog which will allow the programmer to set up the different dialog views available to the programmer. Zoom These buttons are used to either increase or decrease the size of the Ladder View. The (+) button increases the size of the view. The Out (-) button decreases the size of the view. Help This button will open the Help menu window. 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D 4-4 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Online Toolbar Components The following button icons are available after the PLC is placed on line. 1 Online Toolbar Read the Program From PLC This button will read the program from the online PLC. Write the Program to PLC This button will write the program to the online PLC. Program Status This button will turn on the status display for the current ladder logic view. New Data View Using this button will open a Data View window (see Chapter 10). Change Value This button will open the Change Value window to allow the programmer to change element status, values, etc.. PLC Mode This button opens the Mode window to display the current mode of the PLC and to allow the Mode of the PLC to be changed. Choices are Run, Program and Test. System Information Use this button to open a window with the version, status and error information about the PLC. Syntax This button will run a Syntax check of the PLC and a Duplicate I/O check. Toolbar Options This arrow will allow the programmer to add or delete buttons from the toobar, also will view additional buttons that would not fit on the display screen. DirectSOFT 5 User Manual, 1st Edition 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D 4-5 Chapter 4: Programming Environment Additional Toolbars 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D In addition to the default Offline and Online toolbars, other toolbars can be activated and used if desired. To view additional toolbars click on View > Toolbars and select the toolbar or toolbars that would assist you with editing your program. The Toolbar selection window lists fourteen toolbars and a Customize option. The three toolbars at the top of the list are checked since they are the default toolbars. The rest of the toolbars are optional, and they can be selected if desired. Note the down arrow at the end of each toolbar. This down arrow allows the programmer to customize the toolbar by adding or removing buttons. After selecting the file toolbar, it will be added to the Ladder View window beneath the Online toolbar as shown in the diagram below. This toolbar can be moved to any location of the programmer’s preference by dragging it with the mouse arrow. Added Toolbar 4-6 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The File Toolbar The File Toolbar duplicates the more commonly used commands from the main menu File. Notice that the icon buttons are in groups, divided by a gray vertical line. 1 2 3 4 New Online Project 5 Create a new project that linked to the PLC. 6 Close Project This button will close the current project. A message window will 7 pop-up if the program has not been saved. The program can then be saved. 8 Save Project to Disk This button will save the entire project to disk, and will also create a 9 new auto-backup version of the project. 0 Save Project to PLC Use this button to save the entire project to the PLC. 1 Save As to Disk Use this button to save the active project to a different disk file. 2 Import This button will allow the programmer to import a project from a non- 3 DirectSOFT5 format. 4 Import Element Document This button allows the programmer to import a document containing A nicknames, wiring information and descriptions from comma separated variable (.csv) text format. B Import Rung Comments C This button will allow the importation rung comments in text form from a ladder logic program. D Export This button is used to export a project to a non-DirectSOFT5 format (see Chapter 6). DirectSOFT 5 User Manual, 1st Edition 4-7 Chapter 4: Programming Environment Export Element Comments This button allows the programmer to export element documentation containing nicknames, wiring information and descriptions in the current DirectSOFT 5 project to a text file in comma separated variable text format. Export Rung Comments This button will allow the programmer to export the active ladder logic rung comments in text form. Preview the Program Use this button to display the current view as it would appear in printed format. Once previewed, the program can be printed. Print This will allow the printing of the current view and selected documents. Print All Use this button to allow the programmer to print all of the documents that are selected. Setup This button will open the printer setup dialog. Property This button will show the project properties. Exit This button will allow the programmer to exit the project. If the project has not been saved, a pop-up window will remind the programmer to save the project, otherwise, the project will close. 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D The Edit Toolbar The Edit Toolbar is only active in the Edit Mode. It duplicates some of the main menu Edit commands. Undo Use this button to undo the changes to the current rung that has been edited and not yet compiled. The edit cursor must be on the rung to be restored when the undo button is clicked on. 4-8 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Delete The Delete button will delete the element under the edit cursor. If there is no element under the cursor to be deleted, a pop-up message asks if the rung is to be deleted. If multible rungs are selected (highlighted), it will delete these rungs (SeeChapter 5). Insert This button will allow rows and columns to be inserted in a rung. Merge the Previous Rung This button will merge the previous rung with the current rung. Merge the Next Rung Use this button to merge the next rung with the current rung. Browse Contact This button will open the Instruction Browser window ready for a contact to be selected. Browse Coil This button opens the Instruction Browser window ready for the selection of a coil. Browse Boxes Use this button to open the Instruction Browser with the box instructions available for selection. 1 The Search Toolbar The Search Toolbar only contains two command buttons, Replace and GoTo. Replace This button will activate the replace dialog so the programmer can search for an object in the program, or a range of elements and replace them. GoTo This button activates a Goto dialog so the programmer can enter a rung number or addresss he wishes to view. Pressing OK will display the cursor on the desired rung/address. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-9 Chapter 4: Programming Environment The View Toolbar 1 The View Toolbar has three buttons, two of which are from View on the Menu bar. 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Customize This button allows the programmer to display or hide the various Toolbars, to modify the commands that appear on each Toolbar, or to create you own Custom Toolbars. Theme Use this button to select from a variety of User Interface Themes that will give DirectSOFT 5 a new look and feel. You can chose themes, such as, the Office XP theme, the Office 2003 theme, the Mac theme, et al. Color Use this button to activate a Color Setup dialog so the programmer can select different colors for various items in DirectSOFT 5, such as, the background for the Ladder View. 4-10 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The Tools Toolbar The Tool toolbar duplicates the Tools menu from the main menu. These buttons can be a valuable asset to the programmer. 1 Memory Editor This button will open the Memory Editor dialog which will allow the programmer to edit data in V-memory. Documentation Editor This button opens the Documentation Editor view to be used to define Nicknames, Wiring Information and Descriptions for the elements which are used in the program. Assign Nickname DirectSOFT 5 allows the programmer to create an entire program with Nicknames without first assigning them to the actual elements (a.k.a. Symbolic Programming). When the program is ready to be written to the PLC, pressing the Nickname button opens the Assign Nicknames dialog where the programmer can assign actual elements to the unassigned Nicknames used in the program, Comment This button activates the Edit Comments dialog where the programmer can create or modify the comment for the current rung in the Ladder View, or the current stage in the Stage View. Title Use this button to allow the programmer to Edit the title for the project. Compare This button provides a window so the programmer can compare the current program with another program on disk or with the program in the PLC. Insert Instructions This button is used to insert instructins from a Mnemonic text file into the current program, optionally including element documentation. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-11 Chapter 4: Programming Environment The PLC Toolbar 1 The PLC toolbar duplicates the some of the features found on the PLC menu menu bar. 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Connect to PLC This button will allow the programmer to connect the PC to the PLC over a communication link. If a link has not been established, one can be setup here. Disconnect from PLC Use this button to disconnect the PC from the PLC. Link This button will open the Link Info dialog which will provide a quick overview of the current link's status and allows the programmer to edit and set the activation state of the link. Setup (PLC) This button allows the configuration of the PLC type while offline. Display Memory Map Use this button to open the current PLC Memory Map. List Configuration Tools This button will open the Hardware Tools list. The programmer can select a software tool to run from this list as long as it has been installed. I/O Configuration This button will open the Configure I/O window that displays the current configuration of the installed PLC I/O (Chapter 5). Setup a Password This button will allow the programmer to set a password in the PLC to protect the program from unauthorized access. Clear Memory This button is for clearing the memory in the PLC. PLC to Disk This button will allow the programmer to copy the I/O configuration from the PLC to disk. 4-12 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Disk to PLC This button will allow the copying of the configuration data from the disk to the PLC. 1 The PLC Diagnostics Toolbar The buttons on the Diagnostics Toolbar will only be active when the PC is online with the PLC. PLC Diagnostics Pressing this button will perform diagnostics on the connected PLC. Observe the Scan Time Press this button opens the Scan Time dialog which allows the viewing of the current, minimum and maximum scan times from the current PLC. The scan times are continuously updated while the dialog is visible. View Error Messages The messages button will open a window that displays System Errors and Fault Messages which have occurred. The PLC Setup Toolbar Some of the buttons on the PLC Setup Toolbar can be used offline, but all of the buttons can be used with the PLC online. Set the Pause Bits Use this button to open the Pause Bit editor which allows the programmer to set output pause bits. Setup Overrides This button will open the PLC Override editor. Name the Memory Cartridge This will open the Memory Cartridge dialog used to set a name in the current memory cartridge in the PLC. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-13 Chapter 4: Programming Environment The PLC Setup Toolbar (cont’d) 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Set the Retentive Memory Range This button will open a Retentive Range dialog to configure the retentive memory for the current PLC. Set the Watch Dog Timer Pressing this button will allow the programmer to view/edit the watch dog time-out value for the current PLC. Initialize Scratch Pad Pressing this button will begin the process of Initializing the Scratch Pad Memory. Select I/O This button is used to determine which I/O Config will be read from the PLC on power up. I/O Check This button is used to turn on or off the I/O Config check when the PLC powers up. D0-DCM Port Setup This button is used to setup the D0-DCM communication ports. Secondary Port Setup Press this button to setup the PLC Secondary Communication Ports. Setup Global I/O This button is used to setup the global I/O for the DL405 PLC only. Set the Time and Date Press the Calendar button to set the time and date in the PLC. Set up the DV-1000 If there is a DV-1000 installed with the PLC, use this to open the DV1000 setup dialog (refer to the DV-1000 User Manual for setup instructions). Setup the PID Loops The PID button will allow the programmer to setup the PID loop parameters. Select a Memory Cartridge This button will allow the programmer to select the memory type for a DL405 PLC. 4-14 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Setup Intelligent I/O Press this button to open the Intelligent I/O setup dialog to set up intelligent modules. The list contains configuration script for all intelligent modules in the current PLC. 1 The Debug Toolbar The Debug Toolbar extends the use of the Status button located on the Online toolbar. These buttons will assist in the debugging of your program. Turn Status ON in All Views The AllStat button will turn on the status for all of the open views in the current project. Turn Status OFF in All Views The NoStat button will turn off the status for all of the open views in the current project. Open Data View This button will allow the programmer to open an existing Data View. Close Data View This button will allow the programmer to close the current Data View. Save Data View This button will save the current Data View. Data View Save As This button will allow the programmer to save the current Data View with a new name. Test Mode This button will allow the programmer to use the Test Mode Operations (see page 10-22). Stack Operations (DL440 only) Use this button to monitor the DL440 PLC accumulator and data stack. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-15 Chapter 4: Programming Environment Trap Monitor This button will open a dialog which allows the programmer to trap element values at specific addresses rather than after a scan (see page 10-25). 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D The Window Toolbar The Window Toolbar duplicates the window option from the main menu. This toolbar may be helpful if the window views need to be changed often. New Window This button will add a new Ladder View of the current Ladder View. Arrange View Cascaded The Cascade button will rearrange views in a cascaded fashion. Tile Views Horizontally This button will arrange the Ladder/Stage Views in a tiled, horizontal fashion. Tile Views Vertically This button will arrange the Ladder/Stage Views in a tiled, vertical fashion. Arrange Icons Use this button to arrange the icons for minimized windows at the bottom of the main window. If there is an open document window at the bottom of the main window, then some or all of the icons may not be visible because they will be underneath this document window. Default Pressing this button will restore window and toolbar positions to their factory default layout settings. Close All Views This button will close all current views. Output Window This button will display the Output Window. Clear Output Window This button will clear all messages in the Output Window. 4-16 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The Help Toolbar The Help Toolbar duplicates the Help menu accessed from the main menu. 1 Help Topic Index Use this button to open the Help window. PLC/Instruction Matrix This button will open the PLC vs. Instruction Set Matrix window. Getting Started The Start button will open the Help window to provide help to get started using DirectSOFT 5. Tip of Day This button will open the Tip of the Day window to provide a helpful tip. Unlock This button will convert DirectSOFT100 to full version using Purchased Product Keycode. About This button will display the DirectSOFT 5 about box. The Custom Toolbar DirectSOFT 5 has many toolbars to select, and if you select too many, you probably won’t have much room on the monitor to effectively edit a program. The customize toolbar feature may be well suited for your use. Click on Customize at the bottom of the Toolbars menu to open the Customize toolbar window shown below. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-17 Chapter 4: Programming Environment 1 TIP: A quick way to open the Customize Toolbar dialog is to right-click on any of the Toolbars in view. This will access the Toolbars menu, then select ‘Customize... 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D The Customize window will allow the programmer to select all the toolbars he wishes to use, or to customize a personal toolbar. When a toolbar is checked (clicked on) it will be added to the programming window immediately. To create your personal toolbar click on New and name the toolbar. “My toolbar” is the name given to a custom toolbar in the diagram below. The toolbar will be added to the programming window as an add-on toolbar. The toolbar will not have any icon buttons in it until the programmer selects the buttons. To do this, click on the Commands tab and select the command category. Once this is done, a list of icon buttons will appear to the right of the category list. Drag the commands that you wish to the personal toolbar. The name of the personal toolbar will also be added to the list of Toolbar menus. Personal Toolbar 4-18 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Status Bar Components 2 3 4 5 6 7 8 9 0 1 2 3 4 PLC System Information A This status button is active whenever the PLC is online. It displays B OK to indicate the PLC is running without an error. Clicking the button is like using the System Info button in the online toolbar. It will C open the PLC System Information window. D PLC System Information PLC Mode Program Memory Usage Link Information PLC Type Program Location The PLC status information is located at the bottom of the programming window. This area is divided into boxes which contain pertinent information about the PLC operation and status when the PLC is online or offline. These boxes can be classified as status buttons. 1 DirectSOFT 5 User Manual, 1st Edition 4-19 Chapter 4: Programming Environment Communication/Link Information 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D This status button is active when the PLC is offline or online. The button displays the PLC status and the communication link name. Clicking this button will open the Communication/Link Information window. The window will show the communication error messages. It is also possible to edit the communication link if it becomes neccesary. If the PLC is offline, it will indicate that here. Clicking on the button with offline showing will allow the programmer to connect the PLC to the PC. PLC Mode This status button indicates the operational mode of the PLC. Not only does this button indicate the PLC Mode but it also allows the programmer to use this button like the Mode button in the online toolbar. Clicking on this button will allow the person to change the mode of the PLC. Program Memory Usage This box indicates the amount of relay ladder program memory that is available and how much has been used. The format is: memory used/total memory available. If the available memory is exceeded, an asterisk (*) will appear beside the amount used. Here are some examples: • For a DL06 CPU with program memory of 00003/07680 indicates that 3 words have been used out of a total of 07680. • For a DL230 CPU indicating the program memory with *00725/00512. This means that the amount of words used has exceeded the total program memory available (see the diagram on the previous page). PLC Type This box indicates the type of PLC that is being used. Program Location This box indicates the position of the program cursor in the Ladder View. This indicator changes with each movement of the cursor. 4-20 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The Options Dialog Before continuing to edit your program, it is a good idea to get familiar with the DirectSOFT 5 Options Dialog. This dialog actually has six dialogs within which are used to setup the appearance of each of the views available. To open the dialog, either click on the Options button or on View > Options. Each view dialog is indicated by a tab labeled: • Data View - used to monitor and debug the program • Global - this affects all views (display of aliases or nicknames) • Ladder - options for the ladder view • Stage - options used for the stage view • XRef - used to setup the cross reference view (display mode, documentation, etc.) • XRef DB _ definitions for cross reference database queries 1 Only the Global and Ladder options will be discussed in this chapter. The other option tabs will be discussed in later chapters after adequate coverage of some of the more advanced features of DirectSOFT 5. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-21 Chapter 4: Programming Environment Ladder Options 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Number Rungs Two choices are available here, by Address and by Rung. If by Address is chosen, the actual decimal address for each rung will be in located in the left margin of the ladder view, starting with zero. If number by Rung is chosen, the rungs will be numbered beginning with the number one. The following rungs will be numbered sequentially, two, three, four, etc. The default selection is by Rung. Documentation This section of the dialog allows you to select the types of documentation that will appear in the Ladder Logic program. A check mark in the box preceding the option will select the option to appear in the program. The following choices are available: • Elements - the element type and reference number (X1, Y3, C10, etc.) • Nicknames - a name given to the element by the programmer or user (clamp, switch, etc.) • Wiring Info - a descriptive tag for keeping track of wiring (Blue 027) • Descriptions - notes attached to individual elements (gate open, clamp up) • Comments - note attached to the rung, i.e. This is the start of the Wash Process for Section 9 in Building 10 Misc. Options The only option availble here is 3-D Tokens. Leaving this option checked will leave the Ladder View the way it appears when it is first opened (default), that is, with a three dimensional effect on the Ladder View. When this option is unchecked, the Ladder View will have a white background and black rungs. This will not affect the colors of the displayed views. Apply the Options to: By default, the changed options will only affect the Current View. Check All Open Views or New Views if the changes are to affect other opened views or views to be opened later. 4-22 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Global Options The options available with the Global tab affect the current and all new projects that are opened during any session. 1 Selecting the Global Options • Default View - the view that is highlighted in the Default View window when the OK button is selected will be the default view that appears whenever a project is opened. • Display Aliases - Aliases are alternate names given to certain elements or addresses. For example, TA0 is an alias for a timer accumulator data starting at V0. It is much more meaningful to use the aliases rather than the counterpart memory address notations. But in the end, it is a matter of preference. The aliases can be turned ON or OFF globally. See the PLC User Manual for a complete list of aliases for the CPU being used. • Display Nicknames - when this is selected, all current or future projects opened will display the nicknames. Selecting Display Nicknames here will have precedence over how this option is set for the individual views in the other options. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-23 Chapter 4: Programming Environment Colors in DirectSOFT 5 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D Colors are used in DirectSOFT 5 for personal appearance and for certain information. This will be a discussion of how and where colors are used. Select New Colors The programmer can setup the colors that he prefers for the projects to be developed. The selected colors will remain the same for each project. To open the Color Setup window, click on View > Color Setup or click on the Color button in the View toolbar button group. The Color Setup will appear like the dialog below. The colors are changed by selecting the usage (Normal Background, Comment, etc.) under Selection then click on the color in the Colors palette. The Sample area (below the Color palette) has a color bar that will change as the colors are selected. Rows of text will also change color for each type of documentation selected. These are the rows of Cs, Ds, Ws, etc. Click on the desired color Click on item to select for a color change Letters match documentation selections Vertical bars match highlighting for selected rungs, uncompiled, etc. 4-24 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Color Selections Normal Background ȕ the normal background color (the default is white with 3-D Token disabled) Selected Background ȕ used for setting the color that appears when something in the program is selected. For example, if a range of rungs is selected (to copy, delete, etc.) the selection is highlighted with a color (default is blue) Status Background ȕ when online status is selected, this background color shows that the element is enabled (default is aqua) Status Foreground ȕ the color the individual element addresses show when they are active during status Comments ȕ the color used for the rung comments Description ȕ the color used for the element description Wiring Information ȕ the color used to indicate the wiring information Nickname ȕ the color used to indicate the nicknames Element ȕ the color used for the element address (X10, IO000, etc.) Token ȕ the color used for the ladder program 1 The Default Settings If the colors become totally disorganized, click on the Defaults button to restore the colors to the DirectSOFT 5 default settings. Monochrome Selecting the Monochrome button will set all colors to black with a white background. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-25 Chapter 4: Programming Environment Colors Conveying Information 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D DirectSOFT 5 uses different colors to indicate certain conditions. There are color coded vertical bars located in the margin to the left of the program rungs. These bars lets the programmer know what has been compiled and saved. See the diagram below. Uncompiled Background ȕ when a rung is edited, a vertical color bar (default yellow) appears to the left of the program as an indication that the program has not been compiled (accepted). Unsaved to Disk Background ȕ after the program has been compiled, the uncompiled bar is replaced with another bar (default green) to indicate that the program has not been saved the disk. Unsaved to PLC Background ȕ one other color bar is used after a program has been compiled, this bar indicates that the program has not been downloaded to the PLC. Color Bars Uncompiled (Yellow) Compiled, but not written to disk (Green) Compiled, but not written to PLC (Blue) 4-26 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment Select a Theme A dialog window exclusive to DirectSOFT 5 is the Themes dialog. This dialog allows the programmer to select the look of the DirectSOFT 5 programming window, much like selecting the appearance for a computer using Windows. To open the dialog window either click on View > Themes or click on the Theme button in the View toolbar button group. The default theme is Windows XP. 1 The theme selected for the window below is the Beveled look. Note the rounded edges of the menu buttons. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-27 Chapter 4: Programming Environment The Tool Palette 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D An important part of the programming environment is the Ladder Palette. The Ladder palette is visible whenever the programming window is opened. The element symbols are grayed-out and inactive when the not in the Edit Mode. Turning on the Edit Mode activates the Ladder palette and the tool symbols are no longer grayed-out. When a new project is started, the Ladder palette is located on the right side of the programming window by default, however, the palette floats. It can be moved to any position on the monitor viewing area. Simply “grab” the palette with the mouse arrow on the bar at the top of the palette and move it to wherever it may work best for the programmer. The palette can also be resized similar to the one shown on the facing page. Ladder Palette Be Familiar with the Ladder Palette The Ladder palette is very helpful when first learning to use DirectSOFT 5. The hot keys can be learned while using the Ladder palette. The hot keys are labeled on the element keys. Using the hot keys may be quicker for many programmers. The hot keys appear in the “Tool Tip” whenever the cursor is over the element button. NOTE: The Ladder palette which appears on your computer screen may be different than what is shown in this manual. The tools that appear are dependent upon the type of CPU being used. 4-28 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The Ladder palette shown below will be used to describe each button. Edit Mode ȕ turn Edit Mode ON or OFF Normally Open Contact Normally Open Immediate Contact Positive Differential Contact Equal to Contact Equal to or Greater Than Contact Browse Contacts Browse Boxes Wire to Output Accept ȕ compiles the program 1 Normally Closed Contact Normally Closed Immediate Contact Negative Differential Contact Not Equal to Contact Less Than Contact Browse Coils Browse Elements Wrap Wire to Stage The contact buttons are self-explained. Each contact button will place the particular element on the rung wherever the edit cursor is placed. Browse Contacts ȕ click on this button to view the Contact dialog of the Instruction Browser to select a contact of your choice. Browse Coils ȕ click on this button to view the Coil dialog of the Instruction Browser to select a coil of your choice. Browse Boxes ȕ click on this button to view the Box dialog of the Instruction Browser to select an Instruction Box of your choice. Browse Elements ȕ click on this button to view the Element Browser which will allow you to select from various types of memory addresses (X0, Y0, V2000, etc.). This can be used to edit Nicknames, Wiring info or Descriptions of Elements. Wire to Output ȕ clicking this button will turn the horizontal wire between the last contact to the output ON and OFF. Wire to Stage ȕ click on this button to draw a powerflow transition between a contact and a Stage box instruction. 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-29 Chapter 4: Programming Environment The Split Screen Feature 1 2 3 4 5 6 7 8 9 1 11 2 13 4 A B C D There may be times when more than one part of the same program needs to be viewed. DirectSOFT 5 has a split screen feature that allows the programmer to split the program, horizontally, into two panes. Split Screen Bar To use the split screen feature, there is a bar, Split Screen bar, located in the right-hand corner of the Ladder View. To split the screen, position the cursor over the Split Screen bar, then press and hold the left mouse button. When a parallel bar appears, move it down to bring the split screen into view and size the screen to your convenience. The diagram below illustrates the split screen. Notice that the lower pane is showing a different rung than the upper pane. Different parts of the program can be viewed 4-30 DirectSOFT 5 User Manual, 1st Edition Chapter 4: Programming Environment The New Window Feature Another handy feature of DirectSOFT 5 is the New Window feature. This feature is used to open two or more Ladder Views of the same program. Having two or more views open at once can be helpful when programming a lengthy program or to view two different parts of a program simultaneously. To open a new window, click on Window > New Window. You will know that there are two windows open by observing the two Ladder View tabs. To place the two views side by side, click on Window > Tile Vertically. The two views will be displayed like shown in the diagram below. If the Window toolbar group is shown on the programming window, simply click on the NewWn button then the TileVrt button. If desired, the two views can also be arranged tiled horizontally. Notice that the split screen feature has been used in the diagram below. Ladder View 1 has the split screen. 1 Split Screen 2 3 4 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 4-31 EDIT A PROGRAM CHAPTER 5 In This Chapter I/O Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-2 Referencing Program Elements . . . . . . . . . . . . . . . . . .5-4 Entering Program Instructions . . . . . . . . . . . . . . . . . . . .5-6 Shortcuts for Entering Instructions . . . . . . . . . . . . . . .5-11 Drawing/Deleting Connecting Lines . . . . . . . . . . . . . .5-19 Selecting Rungs for Deleting, Cutting or Copying . . .5-21 Deleting Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-22 Copying Rungs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-23 Cut and Paste Rungs . . . . . . . . . . . . . . . . . . . . . . . . .5-25 Merge (Combine) Rungs . . . . . . . . . . . . . . . . . . . . . . .5-26 Inserting Columns, Rows and Rungs . . . . . . . . . . . . .5-27 Using Search and Replace . . . . . . . . . . . . . . . . . . . . .5-29 Common Mistakes . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-31 Chapter 5: Edit a Program I/O Configuration 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D One of the first things to be done before beginning to edit a program is to view the I/O addressing for the PLC being used. Consult the user manual for the PLC that is being used to assist in the I/O configuration. The DirectLOGIC PLCs have automatic I/O configuration, and some of the CPUs offer manual I/O configuration. To access the I/O configuration with DirectSOFT 5, the PLC must be connected to the PC being used and online. Open the new program and connect the PLC to the PC. You can either select PLC > Configure I/O on the Menu bar or press the I/O Configuration button on the PLC Toolbar (the toolbar must have been added to the display window). The Configure I/O dialog pictured on the facing page will appear showing the automatic I/O configuration (by default). If a CPU is being used that can be manually configured and the configuration needs to be changed, click on the “A” next to the slot that is to be manually addressed. The “A” will change to an “M” to allow the address to be changed. 5-2 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Read from disk Save to disk 1 Save to PLC Select manual configuration Read from PLC After the manual configuration has been set, save the configuration to the PLC and to the disk. The disk and PLC icon buttons located in the right-hand corner of the dialog allows the configuration to be either saved or read. WARNING: The majority of DirectLOGIC PLCs only require automatic configuration. Do not use manual configuration unless it is absolutely necessary. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-3 Chapter 5: Edit a Program Referencing Program Elements Data Types 2 3 5 6 7 8 9 1 11 2 13 4 A B C D It’s good to know the various ways to refer to the different types of elements in the PLC. If you have used the DirectLOGIC compatible products, such as the TI305 , TI405 , or SIMATIC® TI versions, you are probably familiar with the way elements are represented. The following table provides a complete list of the various data types and their meanings. TM TM Type of Data DL305C DL05/DL06/DL105 (DL330/DL340 CPU) DL205/DL350/DL405 X Y C S T TA CT CTA GX/GY V P SP VX VY VC VT VCT VGX/VGY VSP PTA PCTA K O B PB Input Points IO Output Points IO Control Relays C Stages S Timers T Timer current TCA Counters CT Counters current TCA Remote I/O Points IO Data Registers R Pointers (to another V location) N/A Special Relays Uses special C locations Input Points as Registers RIO Output Points as Registers RIO Control Relays as Registers RC Timer Status Bits as Registers N/A Counter Status Bits as Registers N/A Remote I/O as Registers RIO Special Relays as Registers RIO Timer current Values as Pointers N/A (to another V location) Counter current Values as Pointers (to another V location) Constants Octal Constants Bit of Word Pointer to Bit of Word N/A K N/A N/A N/A 5-4 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Aliases Chapter 4 briefly mentioned the use of aliases to make some data references easier to understand. By default, they are displayed when you type their counterpart. If it is desired not to have the aliases shown when editing a program, they can be turned off in the Global dialog in the Options menu. Below are examples which show how aliases are used. NOTE: These references are only used within DirectSOFT 5. They cannot be used with the Handheld Programmers. The actual instructions contained in the CPU will reflect the actual data type, not the new reference. 1 Timer/Counter Current Values The DL05, DL06, DL105, DL205, DL350 and DL405 CPUs use designated V-memory locations to hold timer and counter current values. The current value for Timer T0 is stored in V0. This is not always easy to remember, so DirectSOFT 5 allows you to refer to these as either V0 or TA0 (timer accumulated value for Timer 0). For example, the accumulator for Counter 3 is in CTA3 which is easier to remember than V1003. Use Timer Accumulator Reference TA0 K100 OR Use V-memory Location V0 K100 Accessing I/O Points as Memory Locations Aliases allow you to access I/O points as VUse VX reference to I/O memory (registers in a DL305C). For example, input points X0 - X17 in a DL405 LD are stored in V40400, X20 - X37 are stored in VX20 V40401, etc. VX0 (the alias) can be used instead of V40400, the V-memory location for OR X0. These are on 16-point boundaries, so the next location is VX20, VX40, VX60, etc. For Use V-memory Location the DL305C, you could represent I/O points such as IO10 - IO17 with register location LD RI010. V40401 For example, you may want to read in a range of discrete input points to get a binary pattern into the CPU accumulator. The diagram shows two ways to reference the location. NOTE: Check the appropriate PLC user manual for a description of the accumulator and instructions required for this type of task. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-5 Chapter 5: Edit a Program Entering Program Instructions The Instruction Editor 2 3 5 6 7 8 9 1 11 2 13 4 A B C D The Instruction Editor is a dialog used to enter element data for each type of instruction. The diagram below shows the dialog in the output entry position. The expanded Instruction Editor dialog Click here to close and has a check mark, an X and magnifying accept the entry glass in the upper left-hand corner. The Click here to close check mark (ͱ) is used for accepting an without accepting entry. The (X) is used for closing without accepting an entry. And the magnifying Click here to see the element browser glass will bring up the Element (or click on F9) Browser, which will show the valid ranges for this field. The small color-coded indicators in each field of the input box indicate whether the entry for that field is valid or not. Green is valid and red is not valid or incomplete. Valid entry indicator The indicator in the upper right-hand for the immediate field corner of the box indicates the validity of Master valid entry indicator all fields. For example, in order for the for all fields indicator to turn green, the box will need a valid address such as, V2000. DirectSOFT 5 User Manual, 1st Edition 5-6 Chapter 5: Edit a Program DirectSOFT 5 has two basic types of instruction editor dialogs: single parameter and multiple parameter. The following information explain the two types of dialogs. Single Parameter Instructions Most contact, coil and box instructions have single parameters and are entered with the single parameter dialog. When some dialogs open for input, they automatically use a default element address. For example, if the Cancel Ladder palette button for a normally open contact is used, the Instruction Accept Editor dialog box appears with C0 as the default. This is changed to another address or nickname that meets the program requirements. Click on the ͱ to accept the entry, the X (or ESC) to cancel the entry, or on the element browser button (magnifying glass) to browse through the available element addresses or nicknames, or press Enter to accept the entry. 1 Red indicators show not complete Green Indicators show valid entry Multiple Parameter Instructions Some instructions, such as timers, counters and comparative boolean 1st Operand 2nd Operand contacts require more than one element parameter. For example, for a CTA0 K5 timer, enter the timer number and a preset value. For a comparative boolean contact, enter the memory location and the value to be compared. When the Instruction Editor dialog box appears for these instructions, the cursor appears in the first operand field. Do not press Enter when you complete this entry. Press the Tab key or click on the second field for the next entry. For example, if entering a comparative contact, make the first entry and then press the Tab key to make the next entry. To return to the first field, press the Shift + Tab keys. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-7 Chapter 5: Edit a Program Using the Ladder Palette The Ladder Palette is always in view whenever the programming window is open in DirectSOFT 5. The palette becomes active when the Edit Mode button is pressed. The palette is initially docked to the right of the Ladder view, but when the palette is floating, it can be positioned anywhere on the programming screen. Using the Ladder palette is one of several ways to enter instructions. First, place the edit cursor on the rung where an element is to be placed. Then click on the appropriate instruction on the Ladder palette. If one of the contact buttons (the top ten buttons on the palette), a dialog box will appear to enter the parameters. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Ladder Palette Opening the Instruction Browser Some instructions do not have an element button on the Ladder palette. To enter one of these instructions, click on the appropriate browser button on the palette and select an instruction. There are three buttons on the palette for browsing the contact, coil and box instructions. Clicking on any of the browse buttons will open the Instruction Browser, as shown on the facing page. This will allow selection of the correct instruction from the available lists. The particular browser that appears is dependent of the button that is clicked. Once a selection has been made and the OK button is pressed, the Instruction Editor will appear to have the appropriate information entered. 5-8 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program 1 Browse Contacts (F4) Browse Boxes (F7) Browse Coils (F5) Entering Instructions with Hot Keys When the cursor is moved to one of the Ladder palette buttons, a Tool Tip will appear. The Tool Tips provide a brief description of the button and the associated hot key for that button. You can enter an instruction by pressing the hot key which corresponds to the type of instruction to be entered. For example, to enter a normally opened input, press F2. After the hot key has been pressed, the Instruction Editor dialog will appear. For the browse buttons, the particular Instruction Browser will appear so the proper selection can be made. NOTE: A complete list of the hot keys is available from the Help menu. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-9 Chapter 5: Edit a Program Entering Instructions from the Menu Bar Instructions can also be entered using the Menu bar which will open the Instruction Browser. Click on Edit and select the appropriate browser (contact, coil or box). This will open the Instruction Browser as if one of the browse buttons had been pressed on the Ladder palette. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D 5-10 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Shortcuts for Entering Instructions Once the programmer becomes familiar with DirectSOFT 5, the most common method for entering instructions is to position the cursor on the rung where the instruction is to be entered and type the element address, i.e. X12, C22, Y14, etc.. And, for an instruction box, type in the mnemonic, i.e. LD, OUT, SET, etc. and the Token Selection Editor will appear for a proper selection. Then press Enter. 1 NOTE: Use the Ladder Palette, the hot key equivalent, or select the Coil or Box Browser to enter the OUT box instruction. TIP: The Token Selection Editor feature in DirectSOFT 5 supports Auto Complete with a drop-down list of any matching instructions. For example, if a “TM” is typed over a NOP in the output column, an Auto Complete entry of “TMR” will appear with a list of all output instructions beginning with “TM”, including TMR, TMRA, TMRAF and TMRF. After the proper instruction is selected and entered, the proper Instruction box will appear to be completed with all the proper information. So, if you forget a mnemonic, just enter the first couple of letters to see a list of possible instructions. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-11 Chapter 5: Edit a Program Entering NO and NC Contacts Another quick method for entering contacts is to use the forward slash (/) to toggle between a normally open and a normally closed contact. For example, if X0 was entered as a normally open contact and a normally closed contact is needed instead. Position the cursor over the contact and type X0, then press the (/) key and enter. Just reverse the steps to return the contact to a normally open contact. Position the cursor over the contact and type in the address of the contact 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Press the forward slash (/) key Here are two more shortcuts that can be used when entering elements in your program. The first shortcut requires the Edit cursor to be placed on the rung where a NO contact is to be entered. Type the element address and enter it. The edit box will appear so you can either enter the address or change the contact to NC. The other method is to double-click on the rung where the element is to be placed. Again, the edit box will appear with a NO contact. Enter the address and/or change the contact to NC and press enter. 5-12 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Entering Instructions in Parallel To enter instructions in parallel, make normal contact entries similar to the below diagrams. Two contacts have been entered on Rung 2. With the cursor located after the last contact entry, press Enter. The cursor will move down a space equivallent to a rung. Make another contact or contact entries, such as two more contacts in the illustation below. Once this is done, hold down the Ctrl key and press the up arrow. This will draw a line up to connect the line above. Editing the rung can now be completed. 1 Edit a new line and enter Edit more contacts Use Ctrl + up arrow to draw a line up Draw Rung Lines Key Stroke Ctrl +Up Arrow Ctrl +Up Arrow Ctrl +Up Arrow Ctrl +Up Arrow Function Draw a vertical line up Draw a vertical line down Draw a horizontal line left Draw a horizontal line right 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D NOTE: To delete vertical lines, press and hold the Shift + Ctrl, then press either the up or down arrow. DirectSOFT 5 User Manual, 1st Edition 5-13 Chapter 5: Edit a Program Entering Power Flow Instructions There are some instructions, such as Master Control Relays (MLR/MLS), FOR/NEXT loops, Stage Boxes (SG, ISG), Program Control (GOTO/LBL, INT, SBR), etc., that offset the power rail or are inserted in the power rail of the ladder program. A common mistake among new users of DirectSOFT 5 is to try and edit the offsets using the Ctrl + Arrow (line connector). This will not work. Actually, DirectSOFT 5 will automatically perform the offset whenever the program is accepted (compiled). This will become clear through the examples on the immediate two pages. For this example, the FOR/NEXT instruction will be used and the hot key, F8, will be used to accept the program. Begin by entering the first part of the loop ȕ the FOR instruction. Use the special relay SP1 to activate the loop. Enter the parameter K8 to run the loop 8 times. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Press the F8 key to accept the program. Notice the offset of the power rail. 5-14 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program 1 Now, enter the rungs within the loop offset. End the offset loop by entering NEXT rung. After the program has been accepted, the power rail will show the offset. NOTE: Refer to the PLC User Manual to learn how to use the Power Flow instructions. Some of the instructions of this type may not be available for the PLC that is being used. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-15 Chapter 5: Edit a Program Entering Special Case Elements Some elements are special because they do not follow the usual rules (i.e. 330S Timers/Counters, DL330/DL340 CT674-CT677) or they are entered in, perhaps, different ways than one might expect. This will be discussed on this page and the following page. If you have a DL330, DL340 or compatible PLC, then you know the counters,timers CT674 through CT677 cannot take software presets in the same manner as all its other built-in counters/timers. These counters/timers are designed to have their presets entered via an external hardware device (D3-TCSU Timer/Counter Setpoint Unit). Preset values cannot be entered for CT674-CT677 via the timer/counter entry dialog. This presents a unique situation for DirectSOFT 5 because for these two CPUs, DirectSOFT 5 will always show two input fields timer/counter address and preset) for all of its timers/counters and makes no exception for these special cases. The element can be entered in the ladder logic, but the second field is ignored in the editor dialog. The edit dialog will not allow a preset to be entered. This Second field is intended for presets on all other timers/counters, and not these being discussed. Once the address has been entered in the affore mentioned timers/counters, just press enter to close the box. The preset entry will be made via the D3TCSU thumbwheels, and the preset can only be viewed on the Setpoint Unit. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D A preset cannot be entered for DL330/DL340 Timers/Counters CT674-CT677. Leave the preset field blank. 5-16 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program TI330S/TI325S and DL330P Exceptions If you have a TI330S/TI325S or DL330P, then the situation will be slightly different from the one explained on the previous page. These CPUs do not allow presets for any of their counters/timers via the edit dialog of DirectSOFT 5. It is sometimes confusing to users of previous versions DirectSOFT with other PLCs because of the preset entry. The preset for the counters/timers being discussed do not need a preset entry in the edit dialog. The only entry to be made in the edit dialog is the counter/timer address. Refer to the PLC User Manual for a detailed discussion of how these timers work with their presets. 1 2 3 D 5 6 7 8 9 End Coil 0 All of the instruction sets DirectLOGIC PLCs and compatibles, use an END coil as one of the instructions. This may be a bit different for 1 new users of DirectLOGIC PLCs. The END coil is a marker to designate the end of a program. Every DirectSOFT 5 program must 2 have this instruction. 3 Like all coils, the END coil is found in the Coil Instruction Browser. Some programmers get confused at first and look for the END coil 4 under the Standard Coil category, and they fail to find it. The END coil is located under the Program Control category since in ends the A program. B C D The TI330S/TI325S/DL330P counters/timers do not have a preset field. The END coil is found under Program Control and not under the Standard Control category. DirectSOFT 5 User Manual, 1st Edition 5-17 Chapter 5: Edit a Program Setting and Resetting a Bit Several PLCs in the DirectLOGIC family have a feature that allows setting and resetting individual bits. This is commonly called “Bit-ofWord”. The PLCs which support this feature includes the DL05, DL06, DL250-1 and DL450. The DirectSOFT 5 instructions available for these PLCs offering Bit-of-Word include all of the STR, AND, OR and OUT instructions and all SET and RST instructions. Notice SET and RST examples shown below, the letter ‘b’ precedes the memory location where the bit is to be manipulated in some way. After the V-memory address of the word, use a decimal point and a number between 0 and 15 (zero being the least significant bit) to designate which bit is to be set. For example, b1400.3 is the fourth bit of V1400. Enter the letter ‘b’ followed by the memory address of the word containing the bit to be turned ON. Use a decimal point plus a value between 0 and 15 to designate which bit to turn ON, i.e. B1400.3 is the fourth bit of V1400. Ignore the second field. ....And, to reset the bit.... Use the same decimal point convention with the RST instruction. The same convention is used for the STR, AND, OR and OUT instructions (not shown). 2 3 5 6 7 8 9 1 11 2 13 4 A B C D NOTE: The letter “b” can be entered in either lower case or upper case. The end result will be an upper case “B” appearing in the program. Using Floating Point Math Small, low-end PLCs typically allows the use of integers, but do not allow the use of math containing decimal places. The second type of math just mentioned is called “floating point” math. If the processor for your PLC supports floating point math i.e., DL06, DL250-1, DL260 and DL450, it’s a good idea to learn the conventions used for entering the floating point math elements and parameters. Refer to the user manual for the PLC which you are using. 5-18 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Drawing/Deleting Connecting Lines WARNING: As you read this section pertaining to connecting lines, be aware that elements that have not been connected will be deleted when compiling you program. How to compile all edits is discussed at the end of this chapter. 1 Drawing the Lines Most programs contain a wide variety of rungs with complex series and parallel element connecitons. Most any networks can be built by connecting the contacts, outputs, etc. with horizontal and vertical lines. Enter these lines (refer to Page 5-13) by using the Ctrl key and the arrow keys. For example, press Ctrl + ȇ to draw a vertical line from top to bottom or press Ctrl + Ǟ to draw a horizontal line from left to right. Below is an example network containing combinations of series/parallel elements. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-19 Chapter 5: Edit a Program Create Midline Outputs There are times when you need to use a diagram that is often referred to as a midline output. There are no special procedures required. Enter the contacts and outputs as normal, and use the Ctrl and arrow keys to draw the connecting lines. Below is an example of how a midline output would appear. NOTE: There cannot be any additional logic on the rung between the midline connecting point and the output. See Compiling Errors at the end of this chapter. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D No additional contacts are permitted after the branches Deleting Connecting Lines Deleting lines is similar to creating lines. Use the Edit > Wire > Delete options on the Menu bar or the keyboard Delete key to delete intructions and wires in all directions. A quicker method is to use the Ctrl + Shift + Arrow keys to delete the lines. Below is an example illustrating how to delete lines. In this example, use Ctrl + Shift + ǟ to delete the instruction to the left of the cursor along with the connection wire. 5-20 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Selecting Rungs for Deleting, Cutting or Copying While developing the program, there will be times when you will want to make revisions or correct mistakes. Also, there may be times when a rung needs to be moved (cut and paste) to another location in the program. Or, there may be a rung or rungs that you want to duplicate or repeat several times (copy and paste). The next three pages will illustrate how to do these tasks. The first step to cut copy or delete a rungs is to select them with the Shift + Arrow keys. The selected rungs will be highlighted (default color is blue). The following screen shows an example where a rung is selected to be either deleted, cut or copied. 1 TIP: Use shortcuts to quickly select portions of the program Shift + Home selects all rungs from the current rung to the beginning of the program. Shift + End selects all rungs from the current rung to the end of the program. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-21 Chapter 5: Edit a Program Deleting Rungs 2 3 5 6 7 8 9 1 11 2 13 4 A B C D When deleting one or more rungs, it is with the intention of removing the rung(s) from the program entirely. Delete them by pressing the Delete keyboard function key, or by using the Edit > Delete option from the Menu bar. First, select the rung or rungs to be deleted. Then, press the Delete key, and the rung or rungs will be removed. 5-22 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Copying Rungs A selected rung or rungs can be copied and pasted to another location in your program (or to another open program in Edit mode) by using the method most comfortable to you such as, Ctrl + C keyboard shortcut, Ctrl + Copy from the Menu bar or use the Copy button on the Offline toolbar. The original rungs will not be altered in any way. When the rungs are copied, they are placed in a temporary storage location called a clipboard. 1 A rung or rungs are selected in order to be copied. The copied rungs are held on the clipboard until they are pasted using one of the methods just mentioned, or Ctrl + V. The clipboard is updated whenever a different rung is copied; in other words, the clipboard will only hold one copy at a time. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D The above example shows the copied rung pasted from the clipboard to the next rung location in the program (Rung 4). DirectSOFT 5 User Manual, 1st Edition 5-23 Chapter 5: Edit a Program WARNING: When using Stage instructions, be careful where copied rungs are pasted. This is only true for pasting a rung to an unconditional output that follows a Stage box. 2 3 Unconditional Output 5 6 7 8 9 1 11 2 13 4 A B C D When pasting the copied rung, the unconditional output will be joined to the copied rung. The following example shows the output now being controlled by a conditional input, which was not the intent of the original program. Output now joins the copied rung 5-24 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Cut and Paste Rungs Selected rungs can be moved to a different location in your program by using one of these methods; Edit > Cut from the Menu bar, Cut button on the Offline toolbar or Ctrl + X a the keyboard shortcut. The cut rung (or rungs) is stored on the clipboard until it is pasted at a new location. 1 Use the Menu bar or the Cut button Select the rung or rungs to cut The cut rungs are held on the clipboard until pasted to the new location with either Edit > Paste from the Menu bar, the Paste button on the Offline toolbar or Ctrl + V a the keyboard shortcut is used. The cut rungs will remain on the clipboard until pasted or a new rung is either cut or copied. The clipboard will only hold one selection at a time. To paste the rung (or rungs) to the new location, place the cursor on the rung below where the rung will be inserted. The rung will be inserted above the rung where the cursor was placed. Cut rung is now at Rung 3 location Rung 3 has been moved to Rung 4 position and renumbered 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-25 Chapter 5: Edit a Program Merge (Combine) Rungs 2 3 5 6 7 8 9 1 11 2 13 4 A B C D At times, it may become necessary to combine two rungs in order to edit a single rung. DirectSOFT 5 will allow you to merge the two rungs assuming that the program has not been accepted (compiled) yet. Once the two rungs are merged, you will need to combine the rungs through the normal edit process. To access the merge feature, position the Edit cursor on the current rung either to be merged with the rung after the current rung or before (previous) to the current rung. Next, either select Edit > Merge > Make a Selection or press the Merge Next or Merge Previous buttons on the Edit toolbar. The rungs will be merged so you can edit the rungs into one rung. The rung comment from the current rung will be used as the rung comment for the newly merged rung. See the example diagrams below. Rungs 4 and 5 are to be merged. The screen below shows Rungs 4 and 5 merged, renumbered as Rung 4 and ready to be edited. Also note the original Rung 5 comment is no longer there and the Rung 4 comment remains. A new Rung 4. A new Rung 5. 5-26 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Inserting Columns, Rows and Rungs Inserting instructions and rungs is a simple process with DirectSOFT 5. To perform either of these features either use Edit > Insert on the Menu bar, the Insert button on the Edit toolbar or the Insert keyboard function key. When instructions or rungs are inserted, the addresses and rung numbering will change. 1 Insert a Column to Add an Instruction There may be a time when you need to add an element in a rung of a program, such as within a parallel connection in the rung. To do this, a column is inserted to spread the rung out where the element is to be added. In the example diagrams below, a contact is to be added after X0 in Rung 2. The cursor is placed over X0 then the Insert feature is accessed by one of the three ways mentioned above. An Insert dialog will appear asking what you want to do. Make the proper selections and press OK. In the example, Column and After Cursor is selected. Before Cursor could have been chosen. It depends where you want to place the new contact. Only one rung is affected in the example. Current position. Insert column After Cursor. Note: The cursor does not show when the dialog appears. Column inserted, ready for new element. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 5-27 Chapter 5: Edit a Program Insert a Row or Rung A row can be inserted to either add an instruction or a rung. Inserting a row is performed the same way as inserting a column by either using Edit > Insert on the Menu bar, the Insert button on the Edit toolbar or the Insert keyboard function key. Place the Edit cursor on the rung where the row is to be inserted and use one of the above methods to perform the insertion. Make the appropriate selections on the dialog and press OK. A row will appear for the instruction be added. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Current position. Insert row After Cursor. Note: The cursor does not show when the dialog appears. Add new instruction here. Inserting a rung is done in the same manner as inserting a row, except select Rung in the Insert dialog. A new blank rung is inserted either above or below the Edit cursor position. The new rung is inserted and the rungs are renumberd. Rung 3 is ready to be edited. 5-28 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Using Search and Replace A very useful tool in DirectSOFT 5 is the replace feature. Replace is used to replace one element reference with the reference of another element or a whole range of element addresses in a particular part of the current program or even in the entire program. To access this tool, use one of the following procedures: Search > Replace on the Menu bar, Ctrl + R Hot Key or the Search button on the Search toolbar. The Replace dialog will appear, as shown below, which will allow you to define the search and replace procedure. 1 Add to table button Update in table button Using the Object Section Begin by entering an element reference in the Find what: field. Enter an element reference in the thru field blank if there is a range of references to replace. Leave this field blank if only one reference is involved. Select whichever procedure is to be performed, either Replace or Swap . Choose replace to perform the replace function. For example, X1 to X12. Choose swap to swap the element references from one element to another. For example, X1 is swapped with X12 so X12 is now the former X1 element and X1 is the former X12 element. Next, enter the element reference to be replaced or swaped in the With: field, the thru field is read only and will be filled in as the replacement reference is entered. The Add to table button is used to add the current object to the table which is used to perform multiple replacements at one time (See the diagram on the following page). The Update in table button is pressed if an object within the table needs to be edited. This allows the replacement of the object in the table with the newly edited object. DirectSOFT 5 User Manual, 1st Edition 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D 5-29 Chapter 5: Edit a Program The Search Range Section There are three range selections for the replace procedure: 1. All Ҁ will select the entire program as the replacement range. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D 2. Rung Ҁ will allow a certain range of rungs to be setup to perform the replacement. 3. Address Ҁ will allow a range of addresses to be entered (addresses to be converted to rung boundaries) to perform the replacement. The Document Section There are three ways to handle the documentation whenever elements are replaced or swapped: 1. Move Ҁ selecting this will move the documentation from the source element to the destination element. 2. Copy Ҁ this selection will copy the documentation from the source element to the destination element. 3. Leave Ҁ this will leave the documentation at the source element. The Object Table Section The Object table shows all objects which have been added to the table of replacements. To update an object, selecting it from the table will place the object in the Object section so it can be edited. Use the Delete from table button to delete an entry from the Object table. Press OK once all of the selections have been made on the dialog. 5-30 DirectSOFT 5 User Manual, 1st Edition Chapter 5: Edit a Program Common Mistakes 2 Failure to Enter the Edit Mode 3 Some new users will typically open a project and immediately try to edit a program. Remember that you must enter the Edit Mode. D Entering the Edit Mode can be done in several ways. Use either Ctrl > Edit Mode, Ctrl + E or press the EDIT MODE button located 5 on the Offline toolbar and on the Ladder palette. When in the Edit Mode, the cursor box will turn a solid color. 6 AND above a Join 7 The rule is that after a wire has been drawn down in a rung of logic to AND a sub-rung with a midline output, no additional input logic 8 may appear on the leg of the midline output. 9 0 1 2 3 4 Forgetting to Select Rungs A In order to Cut or Copy a rung or rungs, the rungs must be selected (use Shift + up or down arrows). If a nothing is selected, the Cut B and Copy buttons will be grayed out on the Offline toolbar and on the Menu bar. C D Can not add input logic here. It is not uncommon to make programming errors. The fewer errors made, the quicker a program can be completed. Here are some of the more common errors. 1 DirectSOFT 5 User Manual, 1st Edition 5-31 DOCUMENTATION CHAPTER 6 In This Chapter Turn Documentation On and Off . . . . . . . . . . . . . . . . . .6-2 Using the Documentation Editor . . . . . . . . . . . . . . . . . .6-4 Documenting and Assigning Nicknames . . . . . . . . . . . .6-6 Entering Rung Comments . . . . . . . . . . . . . . . . . . . . . . .6-9 Entering Stage Comments . . . . . . . . . . . . . . . . . . . . .6-12 Importing and Exporting . . . . . . . . . . . . . . . . . . . . . . .6-14 Prevent Documentation Loss . . . . . . . . . . . . . . . . . . .6-28 Chapter 6: Documentation Turn Documentation On and Off 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Documentation is the text associated with the components and structure of a DirectSOFT 5 program which is added for greater clarity. It may refer to the elements, wiring, rungs or stages. All documentation options are turned ON by default when the Options dialog is first opened. The Options Dialog DirectSOFT 5 allows the programmer to turn ON/OFF the documentation in each available view. A quick way to open the Options dialog is to place the mouse cursor in the displayed view and right click the mouse. A pop-up window will appear with Options as one of the selections. Select Options and the dialog will appear like the one shown below. When the dialog opens, the Ladder tab is in view by default. The other views can be selected by clicking on the tab at the top of the dialog. The Ladder tab is showing all of the documentation types checked. Leaving each selection checked turns ON that documentation type to be shown in the program. Unchecking the documentation type will turn it OFF in the program. Most of the Options dialog features have been discussed in Chapter 4. For turning the documentation ON/OFF, only the Ladder, Stage and XRef tabs need to be accessed. 6-2 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Documentation Selections Most documentation refers to individual elements, therefore, it is specific in nature. Listed below are four types of documentation • Elements Ҁ the references for the individual elements, ie. X1, Y10, etc. • Nicknames Ҁ these are alpha-numeric names that are used for the various types of program elements. It is usually easier to remember the name Start Switch than it is to remember that X1 is the input for the switch. 1 2 3 D • Descriptions Ҁ detailed description of an element. This can also be used to add brief trouble-shooting steps, etc. 5 • Wiring Ҁ this can be used to identify panel wiring for the project. 6 7 8 9 0 1 General Documentation 2 Comments are general descriptions that are best suited for descriptions of a program rung, or a section of the program. 3 • Rung Comments Ҁ rung comments are assigned to an individual rung. • Stage Comments Ҁ if you are using the Stage instructions, you can also 4 add comments that describe the contents of any stage. A B C D Description Wiring Info Nickname Element Stage Comments are in this area Rung Comments DirectSOFT 5 User Manual, 1st Edition 6-3 Chapter 6: Documentation Using the Documentation Editor 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Nicknames, wiring information and descriptions for program elements are entered using the Documentation Editor. The editor can be accessed using Tools > Documentation Editor on the Menu bar, Ctrl + D or by pressing the Documentation button on the Tools toolbar. Using the Scroll Buttons There are scroll command buttons (arrowheads) located at the top of the editor. They are shown (both directions) as ̈, ̈ ̈, ̈R, ̈Ȋ, etc. Each button has a different function: ̈ Ҁ Moves one element forward. ̈ ̈ Ҁ Moves one page forward. ̈R Ҁ Moves to the beginning of the next data type (X, Y, C, etc.) ̈ȊҀ Moves to the last documentable type. ̇ Ҁ Moves one element back. ̇ ̇ Ҁ Moves one page back. Ṙ Ҁ Move to the beginning of the previous data type. Ȋ ̇ Ҁ Moves to the beginning of the first documentable point. 6-4 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Copying Documentation Between Elements If it becomes necessary to use the Documentation editor, all of the familiar Windows keyboard shortcuts (copy, cut, paste, etc.) can be used within the editor. For example, if there is a lengthy description for a point, and other points are similar, the information can be copied. The following example will demonstrate how this is accomplished. 1. Position the cursor in the cell to be copied. 2. Double click to highlight the information. 3. Press Ctrl + C to copy the information in the cell. 4. Move the cursor to the element cell where the information is to be copied to. (Use the Find button, Ctrl + F shortcut or scroll). 5. With the cursor in position to paste the information, press Ctrl + V. 1 NOTE: When copying a nickname, the new nickname will have a “?” before and after the newly pasted entry. This occurs because each nickname must be unique. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-5 Chapter 6: Documentation Documenting and Assigning Nicknames Create an Unassigned Nickname 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Element nicknames are used more often than any other type of documentation. As a program is developed using nicknames, element references do not have to be entered when a contact, coil, etc. is entered. Wiring information and descriptions can also be entered without knowing the actual element reference. Unassigned nickname is entered (red indicator remains on). Click OK The nickname is accepted without being linked to an element. Dialog appears when a nickname is entered without being linked to an element. Assign the Nickname to an Element If unassigned nicknames have been used in the program, element references must be assigned before the program can be written to the PLC (the PLC does not recognize nicknames, only element references). The Assign Nicknames dialog is used to assign nicknames to element references. A quick way to open the dialog is to either press F9 (hotkey) or the Assign Nicknames button (if the Tools toolbar is displayed). Another way is to use Tools > Assign Nicknames from the Menu bar. Also, if the Element Browser is open, nickname information can be assigned by clicking on the Assign Nicknames button in the Element Browser and the Assign Nicknames dialog will appear as shown on the facing page. Nicknames can be compiled and saved to disk--and then assigned later, just before downloading to the PLC. 6-6 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Open the Element Browser 1 Click here to open the Assign Nicknames dialog. The Assign Nickname dialog will appear with the list of unassigned nicknames appearing in the Source Nickname column. Select the nickname in the list and enter the element reference for the nickname in the Source Element Column. The reference will be duplicated in the Result column to help avoid accidental entries. Press Assign and and the following dialog will appear as a confirmation of the element entry. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-7 Chapter 6: Documentation If the reference entered is correct, click OK. The Element Browser will be in view again so that wiring information and a description, if any, can be added. Pressing Exit will close the browser and the program will have the new element in the program as shown below. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D 6-8 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Entering Rung Comments Each rung in a DirectSOFT 5 program can have associated comments. Unlike some programming packages from other vendors, the comments are not tied to the outputs. Instead, the comments remain with the rung where the comments are added regardless if other rungs are deleted before a commented rung. To edit a comment, the cursor must be on the rung to where it is to be added. Now, either press the keyboard shortcut Ctrl + K, Tools > Comment Editor on the Menu bar or press the Edit Comments button on the Tools toolbar if it is displayed. The Edit Comments, dialog shown, below will appear. 1 Rung Comment Comments are Free-form The appropriate comment can be added as necessary. The Ladder view is a full screen editor, therefore, backspacing the entire comment is not necessary to fix a spelling error. Instead, position the cursor over the word to be edited and double-click the left mouse button to highlight the word, then type in the corrected word. Selecting Rungs for Comments Once you have edited a rung comment you can use the Page Up and the Page Down keyboard buttons to scroll to another rung comment to edit. A specific rung can be found by using the Goto button on the editor dialog. DirectSOFT 5 will only allow comments to be added to rungs which contain elements programmed in the rung. Comments cannot be entered for rungs which do not contain instructions. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-9 Chapter 6: Documentation Using the Scroll Buttons There are scroll command button (arrowheads) located at the bottom of the dialog. They are shown for both directions as ̈, ̈ ̈, ̈Ȋ, etc. Each button performs a different function: ̈ Ҁ Moves to the next rung comment. ̈ ̈ Ҁ Moves ahead five rung comments. ̈ȊҀ Moves to the end of the last rung comment. ̇ Ҁ Moves to the previous rung comment. ̇ ̇ Ҁ Moves back one comment. Ȋ ̇ Ҁ Moves to the comment for the first rung. Click on the OK button after entering the rung comments. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Use the Editing Keys The keyboard shortcut keys can be used to copy, cut and paste between rungs. 1. Position the cursor at the beginning of the text to be copied or cut. 2. Press and hold the left mouse button and move the cursor to highlight the text, then release the button. The Shift + Arrow keys can also be used to highlight the text. 3. Use the Ctrl + C keys to copy the text or the Ctrl + X keys to cut the text. 4. Locate the rung where the information is to be pasted (Use Previous, Next or Goto). 5. Position the cursor where the text is to be pasted and click the left mouse button, then press Ctrl +V to paste the text. 6. The Delete key can also be used to delete text. 6-10 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Move Rung Comments Rung comments can easily be moved from one rung to another with DirectSOFT 5. This feature is useful after one or more rungs have been inserted by a handheld programmer or by another computer which did not have the documentation files available. The Move comment feature can be used to match the comment(s) with the correct rung(s). Comments can be moved for a single rung or a group of rungs. To move comments, click on the Move button on the dialog. The window will appear within the dialog. 1 Fill in the appropriate fields to specify the source and destination for moving a comment. • Source Ҁ This is the beginning of the group of comments to be moved. Enter the rung number (or address) of the rung with the comments to move. • Destination Ҁ Enter the rung number (or address) of the rung to move the comments to. • Number to Move Ҁ Chose All or enter the number of comments to move from the source to the destination. • Units Ҁ Select either Rung Numbers or Address. Press OK to complete the move or Cancel to exit without performing the operation. NOTE: You can overwrite existing rung comments with this feature. DirectSOFT 5 always provides a confirmation prompt before it completes the move. The message reminds you that any overlapping comments will be changed. This message will appear even if there are no overlapping rungs. It is a reminder that existing rungs can be overwritten. DirectSOFT 5 User Manual, 1st Edition 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D 6-11 Chapter 6: Documentation Entering Stage Comments Use Stage View 2 3 5 6 7 8 9 1 11 2 13 4 A B C D If you are using Stage instructions, comments can be entered for each stage. The Stage View must be displayed in order to enter the comments. With a Ladder View open, the Stage View is opened by clicking on View > Stage View on the Menu bar. Stage Comment Area In order to enter Stage comments, the cursor must be positioned in either of the upper quadrants of the Stage view. To open the comment editor, either click on the keyboard shortcut Ctrl + K, Tools > Comment Editor on the Menu bar or press the Edit Comments button on the Tools toolbar if it is displayed. The Comment editor can also be opened by double-clicking the left mouse button with the cursor positioned in the stage comment area. Note that the comment editor is for Stage comments. Stage Comments 6-12 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Comments are Free-form A new comment can be edited immediately. The appropriate comment can be added as necessary. 1 Selecting Stages to Comment Once you have edited a rung comment you can use the Page Up and the Page Down keyboard buttons to scroll to through the Stages. A specific Stage can be found by using the Goto button on the editor dialog. After the comments have been entered, press the OK button to save the comments and close the editor. Editing the Comments The keyboard shortcut keys can be used to copy, cut and paste between rungs. 1. Position the cursor at the beginning of the text to be copied or cut. 2. Press and hold the left mouse button and move the cursor to highlight the text, then release the button. The Shift + Arrow keys can also be used to highlight the text. 3. Use the Ctrl + C keys to copy the text or the Ctrl + X keys to cut the text. 4. Locate the rung where the information is to be pasted (Use Previous, Next or Goto). 5. Position the cursor where the text is to be pasted and click the left mouse button, then press Ctrl +V to paste the text. 6. The Delete key can also be used to delete text. NOTE: All documentation edits are written to the documentation files when they are entered/edited. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-13 Chapter 6: Documentation Importing and Exporting 2 3 5 6 7 8 9 1 11 2 13 4 A B C D DirectSOFT 5 can import and export ladder programs, element documentation (nicknames, wiring info and descriptions) and rung comments from a project. The Import/Export data is expected to be in CSV format (comma separated variables) which is a popular import/export text format for applications like Microsoft Excel and AutoCAD. For example, Microsoft Excel can be used to generate an element documentation to be imported directly into a DirectSOFT 5 project. The existing element documentation can be exported to a CSV file that can be used in diagrams in an AutoCAD program. Exporting Program Documentation The project must be open in order to export program documentation. Three export options are available to choose from, Program, Element Documentation and Rung Comments. The following steps will show how to export a program. There are two ways to export a program, either select File > Program from the Menu bar or select the Export button on the File toolbar if it is displayed. Either method used will open the Export Program dialog shown on the facing page. File Toolbar File Export Options 6-14 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation In the Export Program dialog, select where the program is to be exported to, enter the program name and click the Save button. 1 The following dialog will appear so options can be selected and saved. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D Click the OK button to save the program to a text file. DirectSOFT 5 User Manual, 1st Edition 6-15 Chapter 6: Documentation The text file can be opened with Notepad or equivalent word processor. The Notepad example below shows what can be exported. Note the Rung Comments and the Element Comments. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D Export Element Documentation Element information can be exported from a project to a .csv file. The following illustrations will show the steps to use to export the documentation. Press the Export Element Documentation button on the File toolbar or select File > Export > Element Documentation to export the documentation. There are three different formats to select from to export. Standard, C-more and KEPDirect Server formats. All formats generate a .csv file in spreadsheet form. 6-16 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation This is a standard format showing an Excel spreadsheet with the element reference in column A, the nickname in column B, wiring information in column C and comments in column D. 1 The illustration below is the C-more format showing an Excel spreadsheet with the tagname (element) in column C, the data type in column D and element reference (Address) in column G. NOTE: If unassigned nicknames are exported, they will appear in the resultant text as the following types: UB - unassigned bit UBY - unassigned byte (useful only for R memory in the DL305) UW - unassigned word UDW - unassigned double-word UU - unassigned unknown (used for uninitialized types, should never be used) 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-17 Chapter 6: Documentation Export Rung Comments The program rung comments can be exported from a project to a text file and a printout can be obtained using Microsoft Notepad or equivalent word processor. The following dialog will appear when either pressing the Rung Comments button on the File toolbar if it is displayed or by pressing File > Export > Rung Comments. Select where the file is to be saved, then name the text file and press the Save button. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D The illustration below is an example of an exported comment text file shown with Microsoft Notepad. 6-18 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Importing a Program There may be a time when it is necessary to import a DirectSOFT 5 program which has been previously edited and exported as a text file. This could be an entire program or just a few rungs with element nicknames and comments. Use the following illustrated steps to guide you through the import procedure. Begin by opening the New Project dialog from the DirectSOFT 5 Launch window (page 3-4). Cancel the New Project dialog, then either select File > Import > Program or press the Import button on the File toolbar if it is displayed. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-19 Chapter 6: Documentation The Import Program dialog will appear so the program text to be imported can be selected. Select a previously exported DirectSOFT 5 program to import. Choose the program text file and click Open. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D The complete imported program will appear as shown below. In this example, all elements, element comments, nicknames and rung comments appear in the program along with the cross reference. 6-20 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Exported programs, element documentation and rung comments can be imported using the DirectSOFT 5 programming window if it has been opened to edit another program. This is done by first saving and closing the current program. Next, either select File > Import > Program or press the Import button on the File toolbar. The program to be imported is selected and opened as shown in the previous example. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-21 Chapter 6: Documentation Importing Element Documentation To import program documentation, a project must be open. This project can be the one currently open. The typical method for importing element documentation is to import a .csv file which has been previously exported. It is possible to generate element documentation using a spreadsheet such as Microsoft Excel or Corel Quattro Pro, but it is important to follow the correct import format. The standard format is in spreadsheet form which should be setup in columns similar to the the example below: element reference in column A, the nickname in column B, wiring information in column C and element comments in column D. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D After importing a program the element information can be imported next. To do this, select File > Import > Element Documentation or press the Import Element Doc button on the File toolbar. The following window will appear. Select the folder and the .csv file to be 6-22 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation imported. Notice the Import Method box located on the right side of the window. There are three import methods to select: Merge (.PRJ priority), Merge (.CSV priority) and Delete existing. Selecting one of the three methods will determine the course of action which will be taken if the currently open project and the imported file have duplicate nicknames. If .PRJ priority is selected, the nicknames in the imported file will be added to the project file. If there are duplicates, the nickname in the project file will be kept. If .CSV priority is selected, the nicknames will be added to the project file. If there are duplicate nicknames, the import file will overwrite the ones in the project file. If Delete existing is selected, all of the element documentation of the open project will be deleted, then it will be rebuilt with the contents of the .csv file. Press the Open button to execute the import. NOTE: If the following element types are imported, they will appear in the “ under the element type DirectSOFT 5 documentation editor with “ column: UB - unassigned bit UBY - unassigned byte (useful only for R memory in the DL305) UW - unassigned word UDW - unassigned double-word UU - unassigned unknown (used for uninitialized types, should never be used) 1 Once the element documentation is imported, the Documentation editor will be updated with the imported information. This can be verified by opening the Documentation editor from Tools on the Menu bar, the Documentation Editor button on the Tools toolbar if it is displayed or use Ctrl + D. When the elements are created or if they are already used in the program, the element will be updated with the new information. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-23 Chapter 6: Documentation Importing Program Comments Exported program comments are imported like the element documentation as described on the previous two pages. To do this, select File > Import > Rung Comments on the Menu bar or press the Import Rung Comments button on the File toolbar. The following window will appear. Select the folder and the .txt file to be 2 3 5 6 7 8 9 1 11 2 13 4 A B C D imported. Also select the Import Method to use. Merge (.PRJ priority) if the current project is to remain in place when the import is executed. If comment matching occurs, a message will appear asking which one to update, the imported file or the existing file. Selecting Merge (.TXT priority) will allow the imported comments to overwrite the existing ones. Delete Existing will delete the current comments and update with the imported comments. Insert Instructions The Insert Instructions From File feature will allow the insertion of mnemonic text files as instructions within an open project. Mnemonic instructions can be inserted one time or several times within a program. To use this feature, there must be an existing text file, such as, a file written with MS Notepad. This file must be written in mnemonic text form like the example below. Note that rung PLC type Ladder mnemonics “Reference”,”Nickname”,”Wire number”,”Comment” 6-24 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation comments, element descriptions and element comments can be edited within the text file to be inserted. The text file needs to be edited in the same format as shown, with a PLC type at the beginning, #BEGIN, the documentation and #END. Quotation marks are placed around each line of rung comments. Of course, the ladder mnemonics is also edited with the text file. The element documentation must be in this form: “element reference”, “element nickname”, “wire number”, “comment”. Quotation marks must be used with each entry followed by a comma. If an entry is to be left blank, the quotation marks must not be omitted. The mnemonics text which is to be inserted can also be edited without comments like the example below. Note the PLC type is at the beginning of the text. 1 To insert the mnemonic text in a program being edited (Edit Mode), either use the Tools > Insert Instructions From File on the Menu bar or press the Insert Instructions button on the Tools toolbar if it is displayed. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-25 Chapter 6: Documentation The Insert Instructions dialog will appear. Select the folder where the text file is located, then select the text file to be inserted. Next, choose either Insert at Beginning, End or Before Rung Number. How the element documentation can be imported involving “collisions” with existing program documentation can also be chosen. Select Merge (.PRJ Priority) if the existing project documentation is to remain unchanged. Select Merge (.TXT Priority) if the new documentation is to overwrite the existing documentation in the program. If the program element documentation is not to be changed, select Ignore Element Documentation. Press the Open button to execute the instruction. 2 3 5 6 7 8 9 1 11 2 13 4 A B C D The DirectSOFT 5 Ladder view now displays the inserted instructions and documentation. 6-26 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Restore One option which the Insert Instructions function has that can be useful is the Restore feature. Each time the Insert Instructions is executed, a backup copy of the entire program is made before the insert occurs. If an error is made, i.e. wrong code, just press the Restore button and the program will be restored to its original state. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-27 Chapter 6: Documentation Prevent Documentation Loss 2 3 5 6 7 8 9 1 11 2 13 4 A B C D The documentation which is created with DirectSOFT 5 is stored on disk. Each time a project is opened with DirectSOFT 5, there are multiple project files opened. Apply the same precautions to your project as you would with any other database package to avoid data loss. Backing up the project files is the best insurance to prevent loss. Any time changes are made to a project, make a copy of the project before starting. If something goes wrong, the original will remain intact and unchanged. There are four different methods to preserve a project as a program is created and after the project has been completed. The four methods are: Save Project (to disk), Save Project As, Backup Project and Export Program. Save Project Save Project to Disk should be used to save your project often. Your entire project, i.e., program and all documentation will be saved to the drive that is being worked from, usually the C: drive. From the Menu bar, select File > Save Project > to Disk or press Ctrl + S (keyboard shortcut). To save a project to a different folder than the one being worked from or to save a project to a floppy disk, select File > Save Project As from the Menu bar. The save as window will appear so the folder or the floppy disk drive can be selected where the project is to be saved. Name the project, press the Save button and the entire project will be saved. NOTE: The Write to Disk button on the Offline toolbar only saves the ladder logic program. 6-28 DirectSOFT 5 User Manual, 1st Edition Chapter 6: Documentation Backup Project The backup feature is another way to save your project. Selecting File > Backup Project on the Menu bar or pressing the Backup button on the Offline toolbar will open the following dialog asking if the project is to be saved. Press the OK button to save the project. 1 The following Backup Project dialog will appear, the project can be saved with the default date/time stamp or rename the folder. A different drive can also be selected to save the project. Date and Time Stamp The last backup method is to use the export program feature as explained previously. This method will save a program to a text file. One advantage of the text file is that the program or comments can be edited without using DirectSOFT 5. Close all other applications that may be running to allow as much free RAM as possible. This not only lessens chances of memory conflicts, but also allows DirectSOFT 5 to run much faster. Consider printing a hard copy of the program at longer intervals. If your computer breaks down or you lose all of the data due to a disk crash, you will at least have a hard copy of the program. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 6-29 OTHER VIEWS CHAPTER 7 In This Chapter Tabbed Views . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-2 Stage (RLLPLUS) View . . . . . . . . . . . . . . . . . . . . . . . . . .7-4 Mnemonic View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-6 Cross Reference (XRef) View . . . . . . . . . . . . . . . . . . . .7-7 PID View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-12 Output Window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-14 View Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-16 Chapter 7: Other Views Tabbed Views 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Using the Ladder View to create ladder logic programs has been discussed to this point. There are other views that are output only. These views will help to organize and better visualize the program. These additional views are Mnemonic, Stage (RLLPLUS), Cross Reference (XRef), Documentation Editor and PID Views. Once these views are opened, each view is easily accessed by a tab located at the top of the display window. This is a new feature with DirectSOFT 5. The Primary Views Ladder, Stage, Mnemonics and XRef Views are the primary views in DirectSOFT 5, and can be accessed by selecting the View submenu from the Menu bar and then selecting the view of your choice with the mouse cursor. When a new project is started, the Ladder and XRef Views appear as the default (refer to page 2-12). The Stage and Mnemonics Views can only be opened from the View submenu or by right-clicking when the mouse cursor is in any open View and selecting a different View from the Local Menu. Tabs Primary Views It is possible to open the Stage and Mnemonic Views along with the Ladder View by selecting the views one at a time from the View submenu, thus providing a Multi-Tabbed Interface (MTI) view. Once the views are open, you can switch from view to view by clicking on the appropriate tab in the display window. The Stage View also displays the Ladder View in the lower part of the view, therefore, it may not be necessary to open the Ladder View. This choice is left to the programmer. 7-2 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views A new DirectSOFT 5 feature is to have the Documentation Editor open as a tabbed view while editing a program. Selecting the Documentation Editor tab allows easy access to the editor. To open the editor, either press the Documentation Editor button on the Tools toolbar (if it is displayed), use Tools > Documentation Editor on the Menu bar or the keyboard shortcut Ctrl + D. One more view, the PID View, will be useful if a PLC with PID loops is being used. This view is only available to the user after at least one PID loop has been setup. Once a PID loop has been setup, the PID View is opened from the View submenu on the Menu bar. If all of the views are open in the Program display window at the same time, the tabs will appear as in the illustration below. For the experienced DirectSOFT user, it is possible to arrange 1 selected views in a Multi-Documentation Interface (MDI) look by clicking on the restore button located in the right-hand corner of each view (NOT the application title bar). The views can then be positioned by the user for his use. Restore buttons 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-3 Chapter 7: Other Views Stage (RLLPLUS) View 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Most of the DirectLOGIC PLCs support the use of RLLPLUS instructions.These instructions (Stage, Jump, etc.) allow the creation of a structured program that can be viewed as a flowchart when the Stage View is enabled. A program flowchart may be easier to follow than a comparable ladder logic program. Troubleshooting RLLPLUS vs. RLL The old saying, “can’t see the forest, because of all the trees” often holds true in ladder logic programming. Some RLL programs may contain many interlocks and complex rungs. It may be difficult to follow the logical flow of activity and the relationships between different parts of the program. This is where Stage programming can be better than ladder logic programming. As a ladder logic program is edited with stages, DirectSOFT 5 will translate the RLL into the equivalent Stage View using much more compact, and easy-tofollow flow diagrams. NOTE: Consult the PLC User Manual, Chapter 7, to learn how to incorporate Stage Instructions in a ladder logic program. An illustration of a Stage View is shown below. The flowchart area is shown in the upper left part of the display while a ladder logic area is shown in the lower half of the display. The two windows are synchronized, in other words, when the flowchart is activated with the cursor, the ladder logic will scroll to the same position in the program. This can aid with troubleshooting the program. When testing a program online with a PLC (status ON), both the flowchart and the ladder logic will track each other, showing the power flow and transitions as they occur. It is possible to look at another Flowchart Stage Comments Ladder Logic 7-4 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views part of the program by opening the Ladder View and tile the two views (refer to page 4-30). The right-hand corner view contains the stage comments. These comments are synchronized with the flowchart area of the display (refer to page 6-12 for details). 1 Stage Components If the flowchart area of the Stage View is being viewed and there is an uncertainty of what a component means, click on the component and the corresponding equivalent in ladder logic will come into view. Help (F1) can also be consulted for more clarity. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-5 Chapter 7: Other Views Mnemonic View 1 Handheld Progammer Aid There may be times when a DirectSOFT 5 user will need to use a handheld programmer (HPP) to modify a DirectSOFT 5 ladder logic program. Since the HPP only uses mnemonics, the Mnemonics View will prove to be useful as a guide. Just open the Mnemonics View and print it on a printer. The hard copy can be carried to the PLC location. Consult the PLC User Manual (Chapter 5) for the proper keystrokes required for entering the mnemonic instructions. 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D NOTE: There are no display options for the Mnemonic View. 7-6 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views Cross Reference (XRef) View As mentioned on page 2-12, the Cross Reference (XRef) and Ladder Views open by default whenever a new project is started. The XRef View can be closed if desired, but since it is a dockable view, it is a good idea to dock it if you do not want to view all the time. Just click on the push-pin to dock it, and hover the mouse cursor over the XRef tab to bring it back into view. Then, click on the XRef View bar at the top to “lock” it in position again. The XRef View has two viewing modes, XRef Mode and Usage Mode. XRef Mode button Usage Mode button Push-pin to dock the XRef 1 XRef Mode The XRef Mode is the default mode when the XRef View is first opened. When in XRef Mode, the Cross Reference Table reports information for all elements that meet the current Query which determines the elements to be included in or excluded from the XRef and Element Usage Tables. The table is divided into four columns: Element - reserved for the element ID, but will display whatever Query is selected in the Options dialog. Rung - rung number where the element is used. Address - the address where the element is located in the program. Instruction - type of instruction that contains the element. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-7 Chapter 7: Other Views A useful feature of the XRef Mode is to double-click the left mouse button on the Rung, Address or Instruction and the program will move to that location. Also, double-clicking the left mouse button on an element will cause the Element Browser to appear. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Change the XRef Query The XRef Element column can contain all four types of documentation available in the Options dialog. To change the Element XRef Query definition, first enable the XRef View by clicking the mouse on the table. Next, open the Options dialog from the Menu bar using View > Options or press the Options button on the Offline toolbar. You can also right-click anywhere in the XRef View and choose Options from the Local Menu. Choose the XRef tab and make the Query selections in the Documentation section to be displayed in the Element column. Press OK after making the selections. The other two sections located in the dialog, Display Mode and Usage Options, contain options that can be selected on the XRef View toolbar. 7-8 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views XRef Toolbar The Cross Reference View has a toolbar to move quickly to different locations and views in a program. The available buttons can be seen in the illustation below. XRef Mode Specify XRef Rung Previous XRef Rung Manual rebuild XRef and Element Usage Tables Usage Mode Rung XRef Next XRef Rung 1 XRef Mode Ҁ this button brings the Cross Reference table into view if it is not in view. Usage Mode Ҁ pressing this button brings the Element Usage table into view. Rung XRef Ҁ this button transfers the current mode to a one rung mode which only displays one rung in the table. Specify XRef Rung Ҁ enabled only in the single rung view. Enter a rung number or an address in the dialog pictured below., then click OK. The program will go to and display the rung number entered. Previous XRef Rung Ҁ the Ladder View will display the previous rung while only in the Rung Mode. Next XRef Rung Ҁ the Ladder View will display the the next rung while in only the Rung Mode. Manual Rebuild XRef and Element Usage Tables Ҁ manual rebuild for elements either added or deleted later in a program. This button will be inactive unless Auto Rebuild is not selected in the XRef DB dialog (see page 7-11). 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-9 Chapter 7: Other Views Usage Mode 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D The Usage Mode is selected to display the Element Usage Table in the current Cross Reference View. The Element Usage Table displays all elements that meet the current Query. The table is an effective way to see which points have been used, which points are free and whether or not they have been used in a range. The elements are shown in groups of 8, 10 or 16 bits as determined by the current Usage Field Size setting Usage Mode Usage Mode Element Usage Table Usage Mode Toolbar The Usage Mode toolbar is used to select various options for viewing the Element Usage table. Limit range of elements to the current PLC. Select the XRef Mode Usage Table select button Toggle element references to read left to right or right to left. Set usage field display length. Rebuild XRef and Element Usage Tables 7-10 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views XRef DB There is one more tab on the Options dialog that can be used for setting up the Query for the XRef View. It is the XRef DB tab as seen in the dialog below. This dialog opens with the default selections as shown. In most cases, this dialog should remain as is. The Auto Rebuild may be the only selection to be disabled if it is desired to manually update the Cross Reference View whenever an element is added or deleted. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-11 Chapter 7: Other Views PID View 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D The PID View will be useful as a PID loop tuning aid. To access this view, at least one PID loop must be setup. NOTE: Refer to your PLC User Manual, Chapter 8, PID Loop Setup to setup a PID loop. PID Setup To setup a PID loop, the PC must be connected to a PLC which is online. To begin, either press the PID button located on the PLC Setup toolbar (if displayed) or use PLC > Setup > PID. This will open PID Address dialog as pictured below. After this dialog has been completed and saved, the Setup PID dialog, pictured below, is opened by using the same procedure as discribed above. The Setup PID dialog is a series of dialogs used to setup one or more PID loops. Use the PLC User Manual as a guide to setup the loop(s). 7-12 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views Once a PID loop has been setup, open the PID View by selecting it from the View submenu on the Menu bar. A Data View can also be open to assist in tuning the PID loop(s). 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-13 Chapter 7: Other Views Output Window 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D There may be an occasion when a mistake(s) has gone unnoticed while a program is being edited. The mistake(s) will be detected by DirectSOFT 5 whenever the program is accepted (compiled), and displayed in the Output window as shown below. Edit cursor will move to the error position. Double-click on error on error message The Output window will appear below the view being displayed, in this case, the Ladder View. Each mistake or error message will be listed. Double-clicking on the error in the Output window will move the edit cursor to the error in the ladder view. Once all of the errors are corrected, the program can be compiled. The error messages in the Output window will disappear but the window will remain in view as can be seen in the diagram on the facing page. In the two diagrams with the Ladder View, notice the push-pin in the upper right-hand corner of the Output window. Clicking on this pushpin will auto-hide the window, and a tab will be displayed in the lower left-hand corner. More about auto-hide and dockable views will be discussed beginning on page 7-16. 7-14 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views 1 The Output window can be closed just like other windows are closed. If you desire to open the Output window, press the Output button located on the Windows toolbar if it is displa yed. If the Output window is displayed with error messages, it can be cleared by pressing the Clear Output button located next to the Output button on the Windows toolbar. Output tab 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 7-15 Chapter 7: Other Views View Terminology 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D The terms “docked view” and “floating view” have been used in this manual and will be clarified in this section. A “Docked View” or a “docked toolbar” is a view, or toolbar, that is “docked” to a specific edge of the Programming window. “MDI View” (Multi-Documentation Interface) or primary views (Ladder, Stage, PID, etc.) float within the various docked view/toolbars. Initially, the Offline toolbar is docked at the top of the Programming window below the Menu bar. The Online toolbar is also docked at the top, but below the Offline toolbar. The Ladder Palette toolbar is initially docked on the right edge of the Programming window, and the Cross Reference View is docked on the left edge of the window. The initial views are shown in the diagram below which includes the Multi-Tabbed Interface (MTI) views. Viewing the example on the next page, each of these docked views/toolbars can be docked on any edge (e.g. the XRef View can be moved and docked on the right or on the bottom). Notice that the XRef View has been unpinned and placed in a floating position. In this position, the XRef View cannot be placed in a auto-hide position by pinning it until it is back in a docked position. 7-16 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views 1 2 3 D 5 6 All docked views/toolbars can also be Floating views/toolbars, and 7 float outside the application frame (very handy if multiple monitors 8 are being used). The remaining area, bounded by all of these docked views/toobars, is where the primary MTI Views are 9 positioned. One final user interface for dockable views is the capability to group 0 only the dockable views to create a tabbed group of multiple docked views (e.g. 2 Data Views and the XRef View can all be placed in an 1 MTI). This tabbed group can then be docked, floated or auto-hidden as a single entity. To create at this tabbed group, open all of the 2 Data Views to be placed in the group, then drag one Data View on top of a second Data View, and so forth. You can also drag the 3 XRef View over the top of this group to complete the single MTI group. 4 A B C D MTI group under one tab DirectSOFT 5 User Manual, 1st Edition 7-17 Chapter 7: Other Views The following table lists all of the different views/toolbars and all of the possible frame behaviors: Window Frame Behaviors Individual AutoTabbed Group MDI Tabbed Docked hidden DirectSOFT 5 of (cascade, MDI to Edge Floating Window Type Docked to Docked/Autotile, etc. like (MTI) Edge Hidden/Floating Rel 4) All Toolbars Ladder View Stage View Documentation Editor PID View Mnemonic View Cross Reference/ Usage View (XRef) Data View Output Window ͱ ͱ ͱ ͱ ͱ ͱ* ͱ* ͱ* ͱ* ͱ* ͱ* ͱ* ͱ* ͱ* ͱ ͱ ͱ ͱ ͱ ͱ ͱ ͱ ͱ ͱ* ͱ 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D * Ҁ default behavior Note that the Docked/Floating/Auto-hidden/Tabbed Framed windows can all be independently set on a frame by frame basis. For example, you can have the Ladder Palette and the PLC Setup toolbars floating on a second monitor, with the Offline and Online toolbars being docked on the top edge; then have one Data View floating and three other Data Views grouped as a docked tab to the right side of the application; and have the Cross Reference View auto-hidden, and docked on the bottom edge of the application. However, the two different MDI Frame behaviors are exclusively either/or. This means that within a DirectSOFT 5 session, all of the MDI views behave either as individual MDI frames or as MTI frames, but not both at the same time. You cannot have the Ladder View be a MTI and the Stage View and PID View be cascaded as Individual MDI frames. All MDI Views will have Individual behavior or MDI Views will have Tabbed behavior. 7-18 DirectSOFT 5 User Manual, 1st Edition Chapter 7: Other Views Examples of the various Window Frame Behaviors are in the picture below. 1 2 3 D 5 6 7 8 9 0 • Ladder View and Documentation Editor Ҁ MTI View (Tabbed MDI), with Ladder View currently selected. 1 • Offline toolbar, Online toolbar and PLC toolbar Ҁ Docked to the top edge of the application, just below the Menu bar. 2 • Ladder Palette toolbar Ҁ Docked to the right edge of the application. 3 • Data View Data4 Ҁ Docked to the left edge of the application. • Data Views Data2 and Data3 Ҁ Docked as a Group (MTI) to the left 4 edge of the application, with Data3 currently selected. • Data View Data5 Ҁ Auto-hidden/docked Data View that is docked to A the left edge of the application. • XRef View Ҁ Floating XRef View that is floating outside the borders of B the DirectSOFT 5 application window. • PLC Setup Ҁ Floating toolbar that is floating outside the borders of the C DirectSOFT 5 application window. D DirectSOFT 5 User Manual, 1st Edition 7-19 PRINTING CHAPTER 8 In This Chapter Print the Current View . . . . . . . . . . . . . . . . . . . . . . . . . .8-2 Print Multiple Views . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-5 Print View Common Setup . . . . . . . . . . . . . . . . . . . . . .8-7 Using Print Preview . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-8 Print Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . .8-10 Chapter 8: Printing Print the Current View 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D A printout of the program can be very useful when developing a program. A printout will provide a full view of whatever view is displayed in the DirectSOFT 5 programming window. Print the Ladder View To print the Ladder View, use the Print dialog to select the printing options. To open the Print dialog either select File > Print on the Menu bar, press the Print button on the File toolbar if it is displayed or use the keyboard shortcut Ctrl + P. The Print dialog will appear like the one shown below. In this dialog, you can set the range to Select All to print the entire ladder logic or select the Rung to print. Select each of the types of documentation to print with the ladder logic. Select Ladder wire size print all or any part of the ladder logic by either selecting All, Rungs or Addresses to be printed. Select any or all of the ladder documentation to print with the ladder logic. The Miscellaneous settings allows the level of zoom to print and the selection of the number of columns to print, also, the Pen Size allows the selection of the thickness of the pen used to draw wires, contacts, coils and boxes on high resolution printers. 8-2 DirectSOFT 5 User Manual, 1st Edition Chapter 8: Printing Other Print Views There are three additional current view print dialogs, Mnemonics, Stage and Cross Reference. Each dialog is a bit different than the Ladder dialog as noted in the following diagrams. Each view must be enabled (in view in the programming display) to open the Print Views. Mnemonics Print Dialog 1 Select the Start Address and the End Address for printing. Select the Zoom level and number of columns to print. Stage Print Dialog Select the Documentation types for printing. Select the Zoom level and line thickness to print. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 8-3 Chapter 8: Printing Cross Reference Print Dialog 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Edit the range of the current element. Set All enables (checks) all elements. Clear All disables (unchecks) all elements. Select the Elements to print the xref for. Select the number of columns to use for printing XRef/Usage printouts. Check to include the XRef printout and select the documentation to be printed. Check to include the Usage printout and check the options to be printed. 8-4 DirectSOFT 5 User Manual, 1st Edition Chapter 8: Printing Print Multiple Views The advantage of using the Print All dialog is that all of the available print views are available using one dialog. Open the dialog by either selecting File > Print All on the Menu bar or press the Print All button on the File toolbar if it is displayed. The following dialog will appear. The tabs located at the top of the dialog are used 1 to select the print dialog and printout setup. Click on the tab to select the print view. The print views available when the Print All dialog is opened are: Documentation, Ladder and Memory. Clicking on the right arrow on the dialog will move the Mnemonics, Stage and XRef tabs into view. Select the views to be printed by checking the check box next to the view named on the tab. The use for all of the available views has been explained with the exception of the Docs and Memory tabs seen in the Print All diagram. Docs tab Ҁ check the elements to print the documentation for. Edit Ҁ edit the range of the current element. Set All Ҁ enables (checks) all elements to print. Clear All Ҁ disables (unchecks) all elements to print. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 8-5 Chapter 8: Printing Memory tab Ҁ check the V-memory addresses to print the documentation for. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Elements Edit Ҁ edit the V-memory range. Set All Ҁ enables (checks) all V-memory to print. Clear All Ҁ disables (unchecks) all V-memory to print. Miscellaneous Columns Ҁ select the number of columns to use for the V-memory printout. Online / Offline Values Ҁ select whether online data or offline data is to be printed. Formatted Ҁ use previously saved format information rather than raw data. Nicknames - check this to show nicknames instead of element ids. 8-6 DirectSOFT 5 User Manual, 1st Edition Chapter 8: Printing Print View Common Setup The Printer Setup, Page Setup and Options are common to all of the Print Views. 1 Will open the selected or default printer setup dialog. Set print margins. Printer default Set the starting page number for the printout. Edit the title page with project information and print it. Enter a program heading. Select a printer of choice or print to Adobe Acrobat PDF Writer Select a font other than the default font. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 8-7 Chapter 8: Printing Using Print Preview 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D The Print Preview feature is a feature of DirectSOFT 5. It is recommended to use this feature before printing the program. One advantage for using Print Preview before printing is saving printer paper. You will be able to see how the program will appear on paper before it is printed, and corrections can be made before printing. Print Preview Setup Either open the Print Preview dialog from the Menu bar using File > Print Preview or press the Preview button on the File toolbar if it is displayed. Notice that the Print Preview dialog is the same as the Print dialog. The Print Preview is setup in the same manner as the Print dialog, Use the dialog to setup the printer, the page margins, setup the rest of the print options then press OK. 8-8 DirectSOFT 5 User Manual, 1st Edition Chapter 8: Printing Print Preview After pressing the OK button, the Print Preview will appear using the full computer screen. Use the Page buttons at the top of the display to scroll through the program. One Page can also be selected and switched back to two page when desired. If the displayed program does not appear the way you want to, press the Settings button to return to the setup to make corrections. Once the program preview looks the way you want it to look, press the Print button. Print button Page buttons 1 Settings will return to the Print Preview Setup 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 8-9 Chapter 8: Printing Print Troubleshooting 1 Parts of Program not Printed If the program looks good in Print Preview but some parts do not appear on the program printout, there may be a problem with the color setup. When generating the data sent to the printer, DirectSOFT 5 will attempt to make the program printout look as close to the on-screen version as possible, including the colors. If a color printer is being used, there probably isn’t enough contrast between the background and whatever is being printed. If the printer is black and white, the same lack of contrast could be the problem because DirectSOFT 5 will try to generate grayscale colors to match the display colors. One way to solve this problem is to tell DirectSOFT 5 to use monochrome (black and white) for display. If the View toolbar is displayed, press the Color button, otherwise, go to View > Color Setup and click on the Monochrome button, then press OK. After printing is complete, you can return to the Color Setup dialog to restore the original setting. 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Program Prints “Garbage” As a general rule, if the Ladder View looks correct in Print Preview but the program printout shows “garbage”, the first thing to suspect is the printer driver being used. Look on the printer manufacturer’s website for the latest driver for the printer, then download it and install it on the computer. Once this is done, print one page of the program in Print Preview to be sure that the problem has been corrected. DirectSOFT 5 Crashes If DirectSOFT 5 crashes whenever Print or Print Preview is selected, there may be a corrupted printer setting file in DirectSOFT 5. Each project has a printer settings file that is generated whenever a new project is created. It will reside in the project folder, and will have an extension of .prt. To correct this, close DirectSOFT 5 and delete this file by using Windows Explorer. Reopen DirectSOFT 5 and try the print operation again. 8-10 DirectSOFT 5 User Manual, 1st Edition Chapter 8: Printing Another reason for DirectSOFT 5 crashing whenever Print or Print Preview is selected may be from corrupted global printer settings files. There are two files located in DirectSOFT 5\Program\Bin subfolder named PrntSrv.rst and Program.opt. These files can be deleted from the directory after closing DirectSOFT 5. Locate the two files by using Windows Explorer. After deleting the files, reopen DirectSOFT 5 and try the print operation. 1 Print Setup Dialog The Print Setup dialog deserves to be mentioned. Print Setup can be invoked by either using File > Print Setup or pressing the Setup button on the File toolbar. The dialog that appears will be the Properties dialog for the printer being used. If necessary, printer settings can be made here as well as choosing the page layout which includes Landscape and Portrait orientation. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 8-11 SETUP & MANAGE COMMUNICATION LINKS In This Chapter C H A PT ER 9 Establish the Communicaions Link . . . . . . . . . . . . . . . .9-2 Setup a Serial Link . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-2 Setup an Ethernet Link . . . . . . . . . . . . . . . . . . . . . . . . .9-7 Setup a Modem Link . . . . . . . . . . . . . . . . . . . . . . . . . .9-12 Comm Link Options . . . . . . . . . . . . . . . . . . . . . . . . . . .9-20 Going on Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-22 Chapter 9: Setup & Manage Communication Links Establish the Communicaions Link 1 2 3 Setup a Serial Link D Connect the programming cable from the serial port of the PC to the serial port of the PLC (see Appendix A for selecting the proper cable 5 for your PLC). If your PLC has a RUN\TERM\STOP switch, place it in the TERM position. The Link Wizard can automatically determine 6 the majority of communication settings for the PLCs. To establish a new link, activate the Link Wizard from the launch window menu 7 tree, by right-clicking on Comm Links, and then click on Add Link in the dialog that appears. 8 9 1 11 2 13 4 A 1. The next step is to select a communications port. The window at B the top of the facing page will appear showing a list of communication ports. For serial communication, select the port C you will use (commonly COM1) and click Next. D Right click to select Add Link. In order to download a program to the PLC a communication link must be established. This section will show you procedures for setting up a serial link and an Ethernet link using the Link Wizard, and the setup of a modem link. 9-2 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links NOTE: The COMM ports shown in the window below are those which DirectSOFT 5 will attempt to use. Simply because a COMM port is shown in the list does not mean the port actually exists on the PC. Open Windows Control Panel and verify that a port exists in Device Manager. 1 NOTE: The comm port on your PC may have to be enabled (example, COM5). See Appendix B, DS500.ini File 2. The next window will show a list of PLC Families. Select the PLC family by clicking on the appropriate choice. If you are unsure of the PLC family but know which communications protocol to use, select “Not Sure”. If you are using a DirectLOGIC compatible PLC, the Link Wizard will try and detect the PLC type automatically. Click Next when you are finished. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-3 Chapter 9: Setup & Manage Communication Links 3. Now, to choose the protocol and node address. In this step, you will see a choice of either DirectNET or K-Sequence. Assuming you have selected the DirectLOGIC PLC family (not the DL305), the default, KSequence, will be highlighted. The K-Sequence protocol allows you to perform write operations to individual discrete I/O points and control relays. DirectNET protocol cannot write to individual bit locations. (See Appendix A for a list of protocols available for DirectLOGIC and compatible PLCs). If your PLC has been configured with a node address other than 1, enter that address now. Click Next when finished. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D 4. The Link Wizard will attempt to establish a communication link with the PLC using the node address and protocol you have selected. It will try the combination of 9600 Baud, and Odd Parity. If this combination is unsuccessful, an ‘auto-baud’ sequence will be used to try and determine the correct baud rate and parity combination. If these attempts are unsuccessful, the dialog shown at the top of the facing page will be displayed. You can click on the Link Editor button, and manually attempt to adjust the port configuration. See Appendix B for further help. 9-4 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 1 5. If the Link Wizard is successful in communicating with the PLC, the following window will prompt you to enter a unique link name, and a description of the link if desired. The description field allows 32 characters. Enter the name for the link and description then click Finish to return to the DSLaunch window. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-5 Chapter 9: Setup & Manage Communication Links Link Status 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D After creating a link, the name of the link will be displayed in the menu tree under the Comm Links folder icon. When you click on the link all of the configuration information will be displayed in the DSLaunch window. The status field is color-coded to help easily identify the link status. Green Ҁ link is enabled (it is active and you can use it). Yellow Ҁ a link becomes inactive while that specific link is being edited using the Link Editor. Red Ҁ communication error, i.e., the link has been broken or the PLC has lost power. DirectSOFT 5 will automatically attempt to re-establish the link. 9-6 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links Setup an Ethernet Link The Ethernet link is setup using an Ethernet Communications Module (ECOM) installed in the PLC. The DirectSOFT 5 Link Wizard is used to setup the link. The Link Wizard will automatically determine the majority of the communication settings. It will search for any existing connections and try to establish the link. If a link is not present or a new link is to be established, the Link Wizard will need to be activated. The following steps will guide you through the link setup. 1. Open the Link Wizard from the DSLaunch window. Right click on Comm Links folder in the DSLaunch menu tree, then select Add Link. 1 Right click to select Add Link. 2. Select Ethernet as the port in the Link Wizard dialog, the click Next. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-7 Chapter 9: Setup & Manage Communication Links 3. The Transport and the Transport Protocol is chosen in the next dialog. The Transport is nothing more than a network driver. Note the following restrictions: • If the Operating System is Windows NT 4.0/2000 Pro/ all XP versions, the only Transport option available is Winsock. With Windows 98, either Winsock or IPX interrupt can be chosen. • If UDP/IP is chosen as the Transport Protocol, the PLC ECOM module IP address must be changed from its default of 255.255.255.255 before communication will occur. The following dialogs are used for this. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D 4. DirectSOFT 5 will use the specified Transport and Transport Protocol to scan the network for any Ethernet module on the network. After the scan is complete the following dialog will be displayed NOTE: If the dialog is blank, use NetEdit 3 to setup the ECOM module. 9-8 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links If the ECOM module has been setup using NetEdit 3, the Link Wizard dialog will display the information as shown in the sections named Module List and Address Mode. The Module List will display the Ethernet modules that are found on the network, sorted by their Ethernet address. The Ethernet addresses displayed are unique 12 digit addresses assigned to the Ethernet module at the factory. The ECOM module will have a label with the assigned address printed on it. When a device address is selected in the Module List, the current configuration for the selected device is displayed in all fields of the dialog. The Address Mode section displays the module information that was setup using NetEdit 3. There are three module identifiers shown: Module Id, Name, IP address and Ethernet address. Either one of these identifiers can be chosen so the DirectSOFT 5 can locate the Ethernet module on the network. NOTE: It is important to have a unique identifier for the Address Mode on the network. 1 If for some reason you want to change the module’s configuration, press the Setup button to make the adjustments. The following dialog will appear. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D The configuration for the module selected in the Devices field will appear. The fields that are not grayed out can be changed. Be cautious not duplicate any of the information when making changes. DirectSOFT 5 User Manual, 1st Edition 9-9 Chapter 9: Setup & Manage Communication Links Refering to the Ethernet Module Setup dialog on the previous page, the following Configuration fields can be changed: • The Module ID should be a unique numerical identifier. If this field is grayed-out, the module ID dip switches have been set. The only way to change the ID is to change the dip switches (refer to your particular ECOM User Manual). If the field is accessible, enter a new ID. • The Name field can contain up to 32 characters in length. If there isn’t a name in the field or the name is to be changed, enter a unique name. • The Description field can contain any description limited to the available field. • The IP Address field should only be changed whenever the network IP address is changed (refer to your particular ECOM User Manual). The Network Administrator should be able to provide the address. After making any change, press the Update Module button and the changes will be written to the ECOM module. The Query Network button will initiate a rescan of the network using the Transport and Transport Protocol previously specified. Press the Exit button when the changes have been completed. 5. DirectSOFT 5 will attempt to communicate with the Ethernet module using the specified parameters. If successful, the following dialog will ask for a unique Link Name (up to 16 characters) and an optional Link Description (up to 32 characters) to be entered. Press the Finish button to save the link configuration to disk. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D 9-10 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 6. The successfully created link will be listed with all other links in the DSLaunch menu tree in the Comm Links folder. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-11 Chapter 9: Setup & Manage Communication Links Setup a Modem Link 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Establishing modem links have changed from the standard serial link. DirectSOFT 5 uses Telephony Application Programming Interface (TAPI) for modem configurations. The TAPI protocol allows applications to control modems or other telephony devices for operations such as dialing, answering or disconnecting a connection. With the TAPI protocol, all of the modem support is centralized by the Windows operating system. By using TAPI, the Windows modem setup utilities will be used to configure the modem. Configuring the modem in this manner should simplify the setup process and allow the selection of the most recent drivers for the modem being used. NOTE: If the AutomationDirect MDM-TEL serial modem is being used, refer to the ADC MDM-TEL Modem setup folder on the DirectSOFT 5 cd that came with this manual before trying to establish a link through the modem setup. Modem Setup The first series of examples were performed in Windows 2000 and will illustrate how to configure a modem connected to your PC. The examples may differ depending on the Windows operating system being used. 1. Install the modem if not already installed. Refer to the modem’s documentation for installation information. If the modem is to be used for other devices, it will need to be installed a second time. 2.Once the modem has been successfully installed, the properties will need to be edited. In the Windows Start field, select Settings > Control Panel. 9-12 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 3. Select Phone and Modem Options. A dialog with all available modems installed will appear. 4. Choose the Modems tab, then click on Properties at the bottom. 1 5. Choose 9600 as the Maximum Port Speed. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-13 Chapter 9: Setup & Manage Communication Links 6. Select the Advanced tab and click on Change Default Preferences. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D 7. Make Port speed 9600 and choose None for Flow Control. 9-14 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 8. Click on the Advanced tab and choose 8 Data bits., None for Parity and 1 Stop bits. 1 9. Click OK until all dialogs are closed. This will setup your Windows driver so DirectSOFT 5 can use the Windows TAPI control when accessing the modem. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-15 Chapter 9: Setup & Manage Communication Links Configuring the Link 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D With the modem configured correctly, the link to the PLC can now be established. The next series of steps will provide the information necessary for configuring the link using DirectSOFT 5. 1. The Link Wizard can automatically determine the majority of the communication settings, however, the specific modem information (modem type, phone number, etc.) will have to be entered manually. To activate the Link Wizard in the Launch Window, right click on Comm Links in the DSLaunch tree, then select Add Link. Right click to select Add Link. 2. Select Modem as the device, then click the Next button. 9-16 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 3. The Configure Link dialog should now be in view. First, choose the PLC family and CPU type. Click once on the appropriate PLC Family and a list of available CPUs for that family will appear in the PLC Type window for your selection. Also, give the link a name and description. 1 4. Click the Port tab on the dialog to display the port configuration dialog. This dialog is used to setup the port to match the modem’s configuration. Follow the steps below: a. Select Modem in the Devices column. b. Select the modem type that was configured in the Windows modem setup. The can be verified or modified by clicking on the Properties button or a new modem can be setup by clicking on the Add button. c. Enter the dialing information for the modem. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-17 Chapter 9: Setup & Manage Communication Links 5. Click the Protocol tab to display the communication protocol dialog. The communications parameters can be defined further in this dialog. 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D a. Select the communication protocol to use. Refer to the chart in Appendix A for a breakdown of the various CPUs and which protocols are supported on which ports. b. If the PLC has been given a node Address other than 1, enter the new address. c. If necessary, adjust the Timeouts and Retries, however, the default values should be the best choice. 6. Click the Accept button to save the link configuration. The following dialog will appear. If Yes is pressed, DirectSOFT 5 will dial the modem and attempt to verify that it can indeed communicate with the PLC connected to the other modem using the defined parameters in the link. DirectSOFT 5 will hangup after the connection has been made. If No is pressed, the link configuration will simply be saved to disk. 9-18 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links 7. After the link has been successfully setup, the newly configured Modem link will be listed on the DSLaunch tree under Comm Links in the DSLaunch window. The DSLaunch window will display all the information for the link whenever the link is selected. 1 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-19 Chapter 9: Setup & Manage Communication Links Comm Link Options 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D There are several link options available after a link is setup. The link options dialog is opened by right-clicking on the link name which is to be accessed. The available options are shown in the dialog below. Selecting Run will use the link to connect to the PLC. DirectSOFT 5 will connect to the PLC and search it for a program. If a program is found in the PLC, it will be displayed in the programming window without a program name. Also, the displayed program will not have any documentation showing because the documentation is stored with the project on disk and not in the PLC. NOTE: Double-clicking on the link name will also connect to the PLC. Clicking on Error Log... will open the Link Info window displaying all communication errors which have occurred on the link along with active information for the link. 9-20 DirectSOFT 5 User Manual, 1st Edition Chapter 9: Setup & Manage Communication Links Clicking on Edit Link... will open the Configure Link dialog which was used whenever the link was setup. Click on the link to be edited, make the necessary changes then press the Accept button. 1 There may be a time when it becomes necessary to delete a Comm Link. To delete a link, click Delete Link... and the Delete Link dialog will open, like the one below, showing the link name and description to verify that the link is not used any longer. To delete the link, click on Delete!. 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 9-21 Chapter 9: Setup & Manage Communication Links Going on Line 1 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Once the program has been edited and the communications link has been setup, it is time to go online with the PLC and load the program. Connect the PLC With the Ladder View displayed in the Programming window, either press the Connect button on the PLC toolbar (if it is displayed) or use PLC > Connect from the Menu bar. Select the communications link from the Select Link dialog, then select Use Disk from the Online/Offline Differences dialog (refer to pages 2-22 to 2-24). This will load the program into the PLC. The PLC will be in the Program Mode after DirectSOFT 5 completes the download. Press the PLC Mode button on the Online toolbar and click on Run in the PLC Modes dialog to place the PLC online. To disconnect from the PLC, simply press the Disconnect button on the PLC toolbar or use PLC > Disconnect from the Menu bar. Select Yes when asked Are you sure?, then you will be free to shut down. Use the Project Folder Once a project has been saved to disk, the project name will appear on the menu tree in the Project Folder. To open the project, double-click on it’s name. When the programming window is displayed, you can go online following the process just discussed. Use the Link You can also connect to the PLC by using the communications link. Make sure that a cable is connected to the PLC, then select the link name from the menu tree and double-click on it. If there is a program in the PLC, it will be displayed in the Programming window when it appears. Notice that the name of the program is UNTITLED [Ladder View]. The PLC does not store the program name or other documentation in it’s memory. All of the program documentation is stored on disk in the PC. 9-22 DirectSOFT 5 User Manual, 1st Edition DEBUGGING AND MONITORING CHAPTER 10 In This Chapter Monitor with Data View . . . . . . . . . . . . . . . . . . . . . . . .10-2 Change Value Dialog . . . . . . . . . . . . . . . . . . . . . . . .10-16 Using the Memory Editor . . . . . . . . . . . . . . . . . . . . . .10-20 Test Mode Operations for Debugging . . . . . . . . . . . .10-22 Trap Monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10-25 Stack Monitor (DL440 Only) . . . . . . . . . . . . . . . . . . .10-26 Check DirectSOFT 5 File Revision . . . . . . . . . . . . . .10-27 Chapter 10: Debugging and Monitoring Monitor with Data View 1 2 3 D 5 6 7 8 9 10 Chapter 2, Quick Start, described how to edit a program and go online with the PLC. There was also a discussion on how to monitor the status of the program. This chapter will discuss more monitoring and debugging features of DirectSOFT 5. Using Data View Using the Status to monitor a program is very useful. The Data View window is more useful since you can do much more in one view. The Data View window has more advantages, such as: • View status of elements. • Read and write data values. • Multiple Data Views can be open at the same time. • Since they “float”, they can be placed at convenient locations. • Data View is also conveniently docked by default, and can be set to autohide by clicking on the push-pin. Multiple Data Views can be tabbed together as one dockable or floating window. • Use Data View to monitor the program all views (ladder, stage, mnemonic) on the same screen. • The Data View window can be saved by name. • Data View windows are independent of projects, and can be used for multiple projects. 11 2 13 4 A B C D Open a New Data View Window A new Data View window can be opened in any one of three ways; the menu bar Debug > Data View > New, the keyboard shortcut Ctrl + Shift + F3 or the Data button on the Status toolbar. By default, the Data View windows are assigned names Data1, Data2, etc. consecutively. This name can be changed for the current view using the Options dialog. The following diagram is an example of a newly opened Data View. 10-2 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring A Closer Look A closer look at Data View will show the basic components. Data Format Format Size Clear Edits Write All Edits to PLC Edits Column Select Edits Mode Write Current Edit to PLC • Select Edits Mode Ҁ enables/disables the Edits column. When the column is enabled, Edits can be written to the PLC. The Edits column is not available when disabled. • Data Format Ҁ change the format (bit, binary, Octal, decimal, etc.) displayed in the Status column for a selected row. • Format Size Ҁ choose the selected Data Format displayed in the Status column(1, 16, 32, WORD, etc.). • Clear Edits Ҁ this will clear all data entries from the Edits column. • Write Current Edit to PLC Ҁ the data value for one element can be entered in the Edits column and written to the PLC with this button. • Write All Edits to PLC Ҁ multiple data values can be entered in the Edits column and written to the PLC. 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-3 Chapter 10: Debugging and Monitoring Data View Options 1 2 3 D 5 6 7 8 9 10 The Data View window can be customized for a particular user or users. To customize Data View, click on the Data View window, then either use View > Options on the menu bar or press the Options button on the Offline toolbar. The Options dialog will open with the Data View tab in view as shown below. 11 2 13 4 A B C D The dialog will open with default selections checked in the General Settings in the Display 1 tab. More settings are continued in the Display 2 tab. Checking Col 1 shows display format may be beneficial at times. This will show the display format to the right of the element in the first column. Not all requirements are the same, and experimenting with the General Settings will determine what works best for you. 10-4 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Select Bits for Display The Bit Display Settings area to the right of the General Settings, is only available under the Display 1 tab. There are three selections for controlling or monitoring bits with the PLC in the Run Mode, either one, two, all three or none can be selected (enabled). • Status Bits Ҁ when this is enabled, the status of the element will be shown in the Status column if Status On is enabled. • Pause Bits Ҁ enabling this will allow inputs (or other logic) to operate while disabling selected outputs. • Override Bits Ҁ selected I/O points in Data View can be turned ON/OFF if this is enabled. The diagram below shows what a Data View can look like when all three Bit Display Settings are enabled. Notice that the outputs are the only elements to have all three sets of data bit buttons in the Edits column. Each group of bit setting buttons can have the displayed indicator changed from the default to any one of twenty selections. 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A NOTE: The buttons in the Edits column will only be displayed when the PLC B is in the Run Mode and Status is selected. Also, they will be disabled for DirectNET links. C D DirectSOFT 5 User Manual, 1st Edition 10-5 Chapter 10: Debugging and Monitoring Click on the bit button to be changed and a selection window for that button will appear as shown in the diagram below. Make a selection, such as the light bulb, by clicking on it. The indicator will appear in the button and also on the Data View. Click on Status On button to change the indicator. 1 2 3 D 5 6 7 8 9 10 Indicator selection window. 11 2 13 4 A B C D Indicator is in buttons 10-6 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Data View Documentation Options Next to the Display 2 tab is the Doc tab. Select this tab to set up the documentation to be displayed on the Data View window. Whatever documentation (Elements, Nicknames, etc.) is to be displayed in the Element column is enabled or disabled here. The current Data View window can also be renamed from Data1, Data2, Data3, etc. to any name to better identify it. Enter the new name for the current Data View in the Title field. The name entered can contain up to 32 characters. Enter new name here. 1 2 3 D 5 6 7 8 9 10 Apply Options Notice the three boxes next to the Apply options to: circled in the above diagram. These boxes are in view while the dialog is open. Select the view the options are to be applied to when the OK button is pressed. 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-7 Chapter 10: Debugging and Monitoring Data View Mode Options 1 2 3 D 5 6 7 8 9 10 Next to the Doc tab is the Mode tab. The mode selections will determine whether the data in the Status column will be Read Only (no writes) or Read/Write. A Data View can be setup for Read Only if changes to data will not be permitted by whoever is observing it. Read/Write should be selected for monitoring and debugging a program. Leave Safety enabled so the write operation can be confirmed. Make Data View Entries The columns in a new Data View window are blank whenever it is first opened. The first entries to be will be made in the Elements column. The type of entries that can be made are element references, memory addresses or nicknames. For example, control relay C1 or Test Output 1 are valid entries. Also, R000 for a data register or V1200 for a V-memory location can be entered. The example below shows elements and a memory location which have 11 2 13 4 A B C D 10-8 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring been entered while Online with Status enabled. It really doesn’t matter if entries are made in the Element column with the PLC Online or Offline, Status On or Status Off. Entries can be made with the PLC Offline, then it can be placed Online later to monitor the program. Whenever a Data View window is opened, it appears to the left of the Ladder View (see the example on the facing page). Keep in mind that the Data View can be repositioned and resized to make room for a larger Ladder View like the example below. The Data View position in the example may be radical, but it may be more convenient for the user. 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-9 Chapter 10: Debugging and Monitoring Data Format and Size 1 2 3 D 5 6 7 8 9 10 There are two small fields located in the top left-hand corner of the Data View window. The one on the left is the Data Format field which displays the element type when it is selected in the Element column. If the selected element is a bit type, then Bit will be displayed in the field. If desired, Bit can be changed to Binary by 11 2 13 4 A B C D clicking on the down arrow next to the field. A dialog will drop down with the available selections to chose. The field to the right of the Format field is the Data Format Size field. The size refers to the data length. As an example, Bit is equal to 1 and Word is equal to 16 bits. The selection of the Data Format and Size is left up to the programmer monitoring the program. Bit changed to Binary (16 bits) Data Format Types 10-10 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Write the Edits Debugging a program is not beneficial unless the user can change an element or enter data in a memory location. Changes (edits) are made in the Edits column. All of the edits are placed in a buffer prior to writing them to the PLC. There are three buttons located at the top of the Data View window which are associated with the Edit column. These buttons are pointed out in the example below. The Clear Edits button will clear everything out of the Edits buffer so new edits can be entered. Single edits can be entered into memory, such as a counter setpoint value. Simply enter the value in the Edits column in the counter row. A single edit can also turn on a control relay by clicking on the ON button for the relay. Once both types of entries (edits) are made, click on the button with the single arrow pointing to the PLC, Write to PLC. Multiple values or control relays can also be written to the PLC. The entries or ON buttons are selected as for the single edit. After the edits are made, click on the button with four arrows pointing down at the PLC. The edits will be written to the PLC one at a time. Write Current Value to PLC Write Multiple Values to PLC 1 2 3 D 5 6 7 8 9 10 Clear Edits WARNING: I/O points can be turned on by using the Override buttons. Caution must be taken when forcing I/O to prevent accidental harm to personnel and equipment. 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-11 Chapter 10: Debugging and Monitoring Auto-increment 1 2 3 D 5 6 7 8 9 10 Auto-increment is a feature that can be used to enter elements sequentially. For instance, if a group of control relays , C10, C11, C12 and C13 are to be monitored, enter C10 then click on it again, and then hold down Ctrl + Enter and control relays will be entered until the Enter key is released. If there is an element that has been entered previously in Data View, click on the element nickname or reference, then use the Ctrl + Enter keys as mentioned above. The elements will be entered in sequence below the starting point and any elements that were below the start point will be pushed down below that point. Click on an element, then press Ctrl + Enter to make sequential entries. 11 2 13 4 A B C D Editing Entries Editing the entries can only be accomplished by using the standard keyboard shortcuts. Click on the element to be edited, then use either Ctrl + C or Ctrl + X to copy or cut the element. Ctrl + V is used to paste the element. WARNING: Because Data View follows the conventions of spreadsheet pasting, be aware that the pasting operation will overwrite any field that has been selected prior to the paste. Consequently, it is preferred to paste the data into an empty field. Elements can be deleted from a Data View at any time. Select the item by clicking on it, then either use the Delete key, Edit > Delete, the Delete button on the Edit toolbar or right-clicking on the element then select Delete in the pop-up menu. The deleted elements are not placed on the clipboard, therefore lost. 10-12 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring An editing feature that can be useful is the ability to select more than one item in Data View by using the method used to select rungs in the Ladder View. Select the first item in the group, then use the Shift + Arrow keys to mark a range of items either horizontally or vertically. A more simple way to mark items is to click on the first item in the range, and hold the button and drag the mouse arrow over the rest of the last item to mark. The marked items can then either be deleted, cut, copied or you can change the Data Format or Data Size of the selected items all to the same format or size. Save the Data View Window Once the Data View window has been setup for debugging and monitoring a program, it is a good idea to save it so it can be opened and used later. If the Debug toobar is displayed, click on the Save button and the Save dialog will open. The Data View can be named something else instead of the default ( Data1, Data2, etc.), then save the Data View to the Projects folder by clicking on the Save button. The Save dialog can also be opened by using Debug > Data View > Save from the Menu bar. If a duplicate Data View is needed, either use the Save As button on the Debug toolbar or Debug > Data View > Save As form the Menu bar. 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-13 Chapter 10: Debugging and Monitoring Using Pause Bits 1 2 3 D 5 6 7 8 9 10 A Pause Bit can be set for each output in the Data View window. By setting the Pause Bit, the output status can be controlled when the PLC transitions from Test Run to Test Program. The ability to hold output states is useful, since it allows key system I/O points to be maintained. The Pause Bit is set to maintain the output status, and the Pause Bit is turned off to allow the PLC to turn off the output on the transition to Test Program mode. The Pause Bit option is selected for outputs in the Data View Options tab as seen below. The On/Off Pause buttons will then show on the Data View. 11 2 13 4 A B C D To set the Pause Bit for an output, click on the respective pause button (letter P). Click on the blank button to turn the pause feature Off. When in the Off mode, the Pause Bit is not set and the output will turn off on the transition to Test Program. The letter ‘P’ in the Status column indicates the Pause Bit is set for that output. Pause Bits set Pause Buttons 10-14 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Use Override Bits to Control I/O (DL05/06/240/250-1/260/350/450 Only) If your PLC supports Override Bits, they can be set for each input and output using Data View. Setting these bits allows the status of the input or output to be controlled by a programming device instead of the field device wired to the I/O module. It is similar to forcing an I/O ON or OFF. To use the Override Bits, they must be enabled in the Data View Options dialog. Select Override Bits just like the Pause Bits were selected. Click on the Select Mode button at the top of the Data View window to view the Override Bits buttons. Expand the Data View window if necessary so the buttons will show. Select Mode button 1 2 3 D 5 6 7 8 9 10 Override Buttons To set an Override Bit for an I/O point, click on the respective Override button with the letter ‘O’. Clicking on the blank button will turn the Override feature Off. The letter ‘O’ in the status column indicates the Override Bit is set for that I/O point NOTE: Override bits clear out on a Program to Run transition. 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-15 Chapter 10: Debugging and Monitoring Change Value Dialog 1 2 3 D 5 6 7 8 9 10 WARNING: Only authorized personnel should make changes to the program elements or data values. Changes made while the PLC is in Run Mode become effective immediately. Throughly consider the impact of making changes in order to minimize the risk of personal injury or damage to equipment. The Data View window can be used to make dynamic changes to I/O and change data values stored in memory. The status of an I/O point is performed by using the dynamic edit buttons, and the data values are changed by typing new values in the Edit column. Both types of edit take affect only when they are written to the PLC. Use the Change Value Dialog Turning On/Off I/O points (only with Override bits set) and writing data values to memory locations can also be accomplished by using the Change Value dialog. When using this dialog, it is not necessary to have Status on to make changes to the PLC, but it is a good idea to be able to see the changes when they are made. To open the Change Value dialog, either press the Change Value button located on the Online toolbar, use Ctrl + Shift + F2 or, with Status on and not in the Edit mode, double click on the element to change. The following dialog will appear. 11 2 13 4 A B C D The dialog will open with either a default reference or the reference that was double-clicked on showing in the Element window. 10-16 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Specify an Element Reference or Nickname Since nicknames and element references are used when editing a program, they can also be used with the Change Value dialog. If an element with a nickname is enabled in the program when the dialog is opened, the nickname will appear in the Element field. An element does not need to be enabled to open the Change Value dialog. If the default reference (C0) is displayed when the dialog is Specify the element reference or the nickname. Current Value is either ON or OFF. The element type will be displayed here. 1 2 3 D 5 6 7 8 9 10 opened, either type in the element reference or the nickname that is to be changed. The dialog will always open with the Current Value displayed. The displayed element will either be On or Off. The Current Value can also be a memory location. (see below). The Element field can have a memory location. The Curent Value field will display the data in memory. 1 2 3 4 A B C D The data types are displayed here. DirectSOFT 5 User Manual, 1st Edition 10-17 Chapter 10: Debugging and Monitoring Enter a New Value 1 2 3 D 5 6 7 8 9 10 To change the state (value) of bit data type, such as a control relay, enter the reference or nickname. The example diagram below has C1 entered in the Element field. To change it from Off to On, simply click the On under New. Like Data View, the new state will not be written to the PLC until it is told to. Do this by pressing the Write to PLC button. The Current Value will change to read On. Change Current Value to ON. Press the Write to PLC button. 11 2 13 4 A B C D Current Value now reads ON NOTE: To force I/O, use the Override editor. 10-18 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring To write to a V-memory location, type the memory location in the Element field. The value in memory will appear in the current value view. To change the value, enter it in the New field, then press the Write to PLC button.The new value is written to the V-memory Data will be dynamically displayed here. 1 2 3 D 5 6 7 8 9 10 location. The value in the memory location will be displayed under Current Value. When an I/O reference or a memory location is entered in the Element field, the status or value will be displayed in the New value field as well as under the Current Value. By clicking on the Read from PLC button, the Current Value and the New field will be updated with the current status or data. 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-19 Chapter 10: Debugging and Monitoring Using the Memory Editor 1 2 3 D 5 6 7 8 9 10 WARNING: Only authorized personnel should make changes to the program elements or data values. Changes made while the PLC is in Run Mode become effective immediately. Thoroughly consider the impact of making changes in order to minimize the risk of personal injury or damage to equipment. Another debugging tool which DirectSOFT 5 features is the Memory Editor. The Memory Editor can be used to view and change data in a multiple of memory locations. This is especially helpful for: • Entering or changing values in V-memory or Data Registers for use as constants, timer/counter presets, etc. • Entering text strings into a block of V-memory or Data Registers. Either press the Memory Editor (MemEd) button located on the Tools toolbar, use Tools > Memory Editor on the Menu bar or use the keyboard shortcut, Ctrl + Y. The following diagaram is an example of the Memory Editor. 11 2 13 4 A B C D Select the Locations to View To use the Memory Editor, first use the Find button located in the upper right-hand corner of the editor. A dialog will appear for the entry of the memory address to begin the range to be viewed or edited and press OK. NOTE: The Memory Editor cannot be used to access bit registers (I/O as registers or V-memory). For example, R600 is entered to access Timer 600 in a DL305 system, or V1000 to access Counter 0 actual value in a DL05 PLC. 10-20 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Enter memory address for start of range to view. Find button Entering V1000 for the memory range will display the alias CTA0. The alias could have also been entered. Notice the Format area where the default, BCD/Hex, has been automatically selected. This is the proper format for the actual counter value. If the user wishes to view it in a different format, simply click on one of the formats shown to change the default. Also, the data size can be selected in the same manner. How the data is viewed is strictly up to the user. Any one of the sixteen data fields can be selected to enter data. Once new data is entered in the data field, press the Write to PLC button to update the PLC. The Memory Editor will not update the data being viewed automatically. To view data being updated, press the Read from PLC button. Press this button each time you wish to view data being updated. There may be times when a block of memory will be need to be setup with data and saved for use during debugging. Simply enter the data in each data field to be written to the PLC. After entering the data, press the Write to Disk button to save the data. Use the Read from Disk to re-enter the data in memory. Read from Disk and Write to Disk buttons. 1 2 3 D 5 6 7 8 9 10 Read from PLC and Write to PLC buttons. Data fields 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-21 Chapter 10: Debugging and Monitoring Test Mode Operations for Debugging 1 2 3 D 5 6 7 8 9 10 Select Test Mode DirectLOGIC PLCs support most Test Mode operations which DirectSOFT 5 features (only the DL440 and DL450 support all Test Mode operations). Test Mode operations can be a useful tool for debugging programs. Have Status on when using the Test Mode feature to assist with debugging your program. Enter the Test Mode from either the Run Mode or Program Mode, by either pressing the PLC Mode button on the Online toolbar, using PLC > PLC Modes on the Menu bar or using the keyboard shortcut Ctrl + Shift + R. The PLC Modes window shown below will appear. Select Test then OK. 11 2 13 4 A B C D If the PLC is in the Run Mode when Test is selected, the CPU will still be scanning the program and Test RUN will be displayed in the PLC Mode Indicator at the bottom of the program display window. Stop PLC Scan button To use the Test Operations, the PLC must be in the Test Program Mode. The PLC can be placed in the Test Program Mode from the above window by clicking on the Stop PLC Scan button which will be the only button highlighted in the window when in Test Run. The Test Program Mode can also be entered from the Program Mode by opening the PLC Modes window and selecting Test. 10-22 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Test Program Operations There are four operations available for all DirectLOGIC PLCs in the Test mode only: 1. Start PLC Scan Ҁ this places the PLC into the Test Run mode and will start the execution of the PLC. The PLC will continue executing until the Stop PLC Scan button is pressed. 2. Stop PLC Scan Ҁ this places the PLC into the Test Program mode which will stop the execution of the PLC. 3. Single Scan Ҁ will start the execution of the PLC program for one scan, and then stop execution of the program. 4. Multiple Scans Ҁ is used to execute the PLC program for a given number of scans. Use this when in the Test mode. Enter the number of scans in the entry field of the pop-up window, and press OK. The PLC will change to Test Run mode until the given number of scans have been executed at which time the PLC will change to Test Program mode. This item is only available when the PLC is in the Test mode. Two additional Test Operations are only available for the DL440 and DL450 PLCs, they are: Breakpoint Ҁ specify an instruction address at which to stop the PLC. Pressing OK will execute the program until it reaches the address, and then the PLC is placed into Halt Mode. Use this in the Test Program mode, Breakpoint will place the PLC into Test Run mode until the specified address is executed then returns the PLC to Test Halt mode. Use Breakpoint only in the test mode. BREAK Instruction Ҁ this instruction changes the operational mode of the CPU from Run to the Test Program mode. The Break instruction allows V-memory and image register data to be retained where it would normally be cleared with the STOP instruction or a normal Run to Program transition. (see the DL405 User Manual). 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-23 Chapter 10: Debugging and Monitoring The Test Operations Window 1 2 3 D 5 6 7 8 9 10 When in one of the Test Modes, the Test Operations window can be opened with the Test Mode Operations button located on the Debug toolbar or by using Debug > Test Mode Operations from the Menu bar, and the following window will appear. The window has six buttons to be used for Test Operations mentioned on the previous page. The buttons available for each test mode will be highlighted. Only one button, Stop PLC Scan is available in Test Run, and two buttons are only available for use with the DL440/450 PLCs, Single Step and Breakpoint. Start PLC Scan Breakpoint Single Step Multiple Scans Stop PLC Scan Single Scan 11 2 13 4 A B C D 10-24 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Trap Monitor Access the Trap Monitor The DL05/06, DL250-1, DL260 and DL450 uses an additional diagnostic tool called a Trap Monitor. The Trap Monitor is used to trap (capture) element data at a specific address rather than after a scan. The Trap Monitor can be a useful tool if you wish to look at some ladder logic in the Test Run mode. An example might be to check a math routine to see if it is working properly. To use the Trap Monitor, either press the Trap button located on the Debug toolbar, if it is displayed, or use Debug > Trap Monitor on the Menu bar. The Trap Monitor can only by used in the Test Run Mode. If the PLC is not in Test Run, a message will appear to ask you if it is safe to switch the PLC to Test Run mode. Select the “Switch to....” button. Another dialog will appear and ask if you are sure it’s okay to switch to Test Run. Once the PLC is placed in Test Run, the dialog shown below will appear. A definition of the basic components will be helpful before using the Trap Monitor. This is the address of the trapped element (not the rung number). The element trapped at the above address. 1 2 3 D 5 6 7 8 9 10 Enable trap pushpins shown in disabled position. This area is read only and will display the data for the trapped element. Press this button to change the format of the Element Value to be read. The Trap Monitor can be used as seen above by entering the element address and the element reference to read the data in the read only area of the dialog. The address can be left alone while the element reference is being changed it is necessary to read the Element Value at that address. Or, the Address can be incremented or decremented leaving the Element Value alone to check the data at different addresses. DirectSOFT 5 User Manual, 1st Edition 1 2 3 4 A B C D 10-25 Chapter 10: Debugging and Monitoring Another way to use the Trap Monitor is to enable the two Trap pushpins. When the pins are enabled, the Address can be incremented or decremented while observing the Element located at the new Address. The read-only data will also change. 1 2 3 D 5 6 7 8 9 10 11 2 13 4 A B C D If you want to “step” through a program area to check the data in V-memory locations, just leave the Trap Monitor dialog as shown above, then place the ladder program cursor over the element (box) with the memory reference in it. You can then read the data in the read only area. 10-26 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Use with Data View The Trap Monitor is normally used in combination with one or more Data Views so the inputs and outputs of the Ladder Logic or Stage program can be controlled. The Trap Monitor is useful to look at math operations in a program. The format for the values being read can be specified (Decimal, Hex or Octal). Press the button in the lower right-had corner of the dialog to open another dialog to set the format. 1 2 3 D 5 6 7 8 9 10 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-27 Chapter 10: Debugging and Monitoring Stack Monitor (DL440 Only) 1 2 3 D 5 6 7 8 9 10 Access the Stack Monitor Monitors PLC accumulator and data stack. Either use the Debug>Test Mode Operations->Breakpoint dialog or the BREAK instruction to monitor the PLC accumulator and data stack at a specific address. Access the Stack Monitor by either pressing the Stack button located on the Debug toolbar or by selecting Debug > Stack Monitor from the Menu bar. This feature is used most frequently with segments of programming which require debugging math operations. 11 2 13 4 A B C D 10-28 DirectSOFT 5 User Manual, 1st Edition Chapter 10: Debugging and Monitoring Check DirectSOFT 5 File Revision DirectSOFT 5 has a quick and easy method of looking at the various versions of the files which comprise the software. This feature may never be used, however, this may be useful in the future as additional features are added in upgrade packages, new products, etc. Open the Version Browser by double-clicking on Version located under Utilities on the DSLaunch menu tree. Double-click here 1 2 3 D 5 6 7 8 9 10 TIP: A simple way to check the DirectSOFT 5 version is to open a project program and select Help > About. 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition 10-29 PROTOCOLS AND CABLE DIAGRAMS In This Appendix APPENDIX A Cables and Protocols . . . . . . . . . . . . . . . . . . . . . . . . . .A-2 Programming Cable Diagrams . . . . . . . . . . . . . . . . . . .A-6 Appendix A: Cables and Protocals Diagrams Cables and Protocols A 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D DirectLOGIC CPUs provide many communication port possibilities, therefore, it is helpful to know which programming cable and protocol is requireds. Supported Cables Family DirectLOGIC DL05 CPU (or other device) DL05 (all versions) H0-ECOM H0-ECOM100 DL06 (all versions) H0-ECOM H0-ECOM100 Port Port 1 Port 2 Only one Only one Port 1 Port 2 Only one Only one Only one Cable D2-DSCBL D2-DSCBL Ethernet Ethernet D2-DSCBL D2-DSCBL-1 Ethernet Ethernet D2-DSCBL D2-DSCBL D2-DSCBL D2-DSCBL D2-DSCBL D2-DSCBL-1 D2-DSCBL D2-DSCBL-1 D3-DSCBL-2 Ethernet Ethernet D3-DSCBL-2 D3-DSCBL-1 D3-DSCBL-1 D3-DSCBL-2 D4-DSCBL D3-DSCBL-2 D2-DSCBL D4-DSCBL D3-DSCBL-2 D3-DSCBL-2 Ethernet D4-DSCBL DirectLOGIC DL06 DirectLOGIC DL105 (all versions) DL105 DL230 Port one Top port DL240 Bottom port Top port DL250-1 Bottom port DirectLOGIC DL205 Top port DL260 Bottom port D2-DCM Only one H2-ECOM Only one H2-ECOM100 Only one DL330/DL330P Requires DCU* Top port DirectLOGIC DL340 DL305 Bottom port D3-DCM Only one Top port (15-pin) DL430, DL440 Bottom port (25-pin) Phone jack Top port (15-pin) DL450 DirectLOGIC Bottom port RS-232 DL405 Bottom port RS-422 D4-DCM Only one H4-ECOM Only one Slice I/O Modules Only one * Ҁ requires RS232 Data Communications Unit (D3-232-DCU A-2 DirectSOFT 5 User Manual, 1st Edition Appendix A: Cables and Protocals Diagrams A Supported Protocols DirectNET K-Sequence • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • ECOM MODBUS MODBUS TCP • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D • DirectSOFT 5 User Manual, 1st Edition A-3 Appendix A: Cables and Protocals Diagrams Cables and Protocols (cont’d) A 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Supported Cables Family GE Series 1 CPU (or other device) IC610CPU105/106 325-07, PPX:325-07 332-37, PPX:330-37 325S-07 (or 325w/Stage Kt) 330S-37, PPX:330S-37 335-37, PPX:335-37 425-CPU, PPX:425-CPU Port Requires DCU* Requires DCU* Requires DCU* Requires DCU* Requires DCU* Phone Jacks If DCU is used* Only one Cable D3-DSCBL-2 D3-DSCBL-2 D3-DSCBL-2 D3-DSCBL-2 D3-DSCBL-2 D3-DSCBL-1 D3-DSCBL-2 D4-DSCBL TI305/ SIMATIC TI305 TI DL405 N/A, PPX:430-CPU D4-DCM H4-ECOM Slice I/O Modules Top port (15-pin) D4-DSCBL Bottom port (25-pin) D3-DSCBL-2 Top port (15-pin) D4-DSCBL Bottom port (25-pin) D3-DSCBL-2 Only one D4-DSCBL * Ҁ requires RS232 Data Communications Unit (D3-232-DCU A-4 DirectSOFT 5 User Manual, 1st Edition Appendix A: Cables and Protocals Diagrams A Supported Protocols DirectNET K-Sequence • • • • • • • • • • • • • • • 2 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition A-5 Appendix A: Cables and Protocals Diagrams Programming Cable Diagrams A Pin labeling conforms to IBM DTE and DCE standards 2 3 D 5 6 7 8 9 1 11 2 13 4 A B C D ● ● ● ● A-6 DirectSOFT 5 User Manual, 1st Edition COMMUNICATIONS TROUBLESHOOTING In This Appendix APPENDIX B DS500.ini File . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-2 Other Issues . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B-5 Appendix B: Communications Troubleshooting DS500.ini File A B 3 D 5 6 7 8 9 1 11 2 13 4 A B C D It is useful to understand how DirectSOFT 5 handles the communication resources on the PC in order to communicate to the PLC. The following information is provided to help resolve PC to PLC communication problems. DS500.ini File DirectSOFT 5 can connect to PLCs either by using a serial COMM port, a modem or a USB-to-serial adapter. It can also connect with Ethernet 10/100BaseT using an ECOM module installed in the PLC. The user can control which PC communication resources is to be used by DirectSOFT 5. This is accomplished through entries in DS500.ini. This file is located under Utilities on the DSLaunch menu tree. This file can be edited with any text editor such as Notepad. DirectSOFT 5 will have to be restarted if any changes are made to the DS500.ini file. The sections of the DS500.ini file to be concerned with are [devasync.dll] and [devether.dll]. These two sections are used to enable and disable the communications resources which DirectSOFT 5 uses. The settings for these sections do not affect other application used by the PC which use these resources; they only affect DirectSOFT 5. These sections will look like the following in the standard DS500.ini file: [devasync.dll] ;dump=1 COM1Enable=1 COM2Enable=1 COM3Enable=1 COM4Enable=1 ModemEnable=1 COM8Enable=0 COM7Enable=0 COM6Enable=0 COM5Enable=0 [devether.dll] EthernetEnable=1 ;UDPPortNumEnable=1 B-2 DirectSOFT 5 User Manual, 1st Edition Appendix B: Communications Troubleshooting Setting any of the entries to a value of 0 will prevent DirectSOFT 5 from using it. A value of 1 will enable it so DirectSOFT 5 can use it. The value for these entries should be set so they match the resources that are physically present in the PC and are available for DirectSOFT 5 to use. WARNING: It is normally not necessary to make any change to the DS500.ini file unless the user is trying to solve a communication problem with DirectSOFT 5. Save the ds500.ini file if changes are made. A Enable Dump=1 Dump=1, located in the [devasync.dll] section of the DS500.ini file, is used to enable some low level communications debugging for serial and modem connections. DBWin32, a debugging aid for Windows NT/95, is used to view the debugging information. DBWin32 is found by going to DSLaunch and then double-clicking on DBWin32 Logger in the Utilities folder in the DSLaunch Menu tree. This will open the DBWin32 dialog. If this is used, it can be enabled by changing the semicolon (;) to a colon (:) at the beginning of dump=1. This example shows dump=1 enabled. [devasync.dll] :dump=1 COM1Enable=1 COM2Enable=1 COM3Enable=1 COM4Enable=1 ModemEnable=1 COM8Enable=0 COM7Enable=0 COM6Enable=0 COM5Enable=0 B 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition B-3 Appendix B: Communications Troubleshooting Enable AutoSense=0 A B 3 D 5 6 7 8 9 1 11 2 13 4 A B C D Each created link to the PLCs will be validated each time DirectSOFT 5 is started. The communication server will use the link’s parity, baud rate, protocol and station number settings to detect the availability of the PLC. This process may be lengthy because the attempts to communicate must time out if there are several links or some PLCs are not connected to a link. If desired, this feature can be disabled by enabling AutoSense=0 in the the [Comm Server] section of theDS500.ini file by changing the semicolon (;) to a colon (:) at the beginning of AutoSense=0. This example shows the AutoSense=0 enabled. [Comm Server] LastDevice=769 LastProtocol=1025 :AutoSense=0 Startup Issues The first time DirectSOFT 5 starts up its communication server, it attempts to build links to PLCs which are found based on the resources which are enabled by DS500.ini. The communications server will try to use fixed combinations of Baud rate, parity and station number for both K-sequence and DirectNET protocols. If a PLC responds, a link will be created. It’s the attempt to create a link that can cause a problem. Most of the time, if DirectSOFT 5 attempts to use a resource that physically isn’t present on the PC, nothing happens. But this action can have adverse effects on some PCs, especially in situations like leaving EthernetEnable=1 on PCs without an Ethernet card installed and configured or if the IPX protocol is not installed. B-4 DirectSOFT 5 User Manual, 1st Edition Appendix B: Communications Troubleshooting Other Issues USB-to-Serial Converters The use of USB-to-Serial converters has become an issue since more and more PC vendors remove serial ports from their PCs in favor of additional USB ports. In theory, there shoud be not problems with this as long as the USB-to-Serial drivers function like a standard PC serial port. There has been some changes made to the communications server to better handle these converters. It is highly recommended to install the device drivers for the USB-to-Serial converters before attaching the converter to the PC. This is common practice for all USB devices and it is important for some vendor’s products. A Microsoft ActiveSync ActiveSync is the software used to synchronize data between the PC and a PDA running Windows CE or Pocket PC. This software has an undesirable habit of attaching itself to the serial ports of the PC it’s installed on in order to auto-detect the presence of the PDAs. The DirectSOFT 5 error dialog will show the symptom for this problem: “Error connecting to PLC!” “Error: cannot access comm port. The port may not be present or another app may be using it.” The COM ports that ActiveSync has control of can be restricted by going to it’s File > Connection Settings menu. NOTE: Other software, such as GPS, RSLogix, IR drivers and digital cameras, might cause this problem also. B 3 D 5 6 7 8 9 0 1 2 3 4 A B C D DirectSOFT 5 User Manual, 1st Edition B-5 Index INDEX A Auto-increment 10-12 AutoSense=0 B-4 devasync.dll B-2 Documentation Editor 7-3 DS500.ini B-2 DSLaunch window 3-2 Dump=1 B-5 C Cable Diagrams A-6 Colors in DirectSOFT 5 4-24 Color Bars 4-25 Color Setup 4-26 Communication Link 2-20 Link Wizard 2-20 Protocol and Node Address 2-21 Select Link 2-20 Compare Programs 2-23 Connecting Lines 5-19 Copy or Save Existing Files 3-7 Current Value 10-17 E ECOM 9-7 element references 10-17 End Coil 5-17 End Rung 2-17 Error Log 9-20 Ethernet link 9-7 Exporting 6-14 Element Documentation 6-16 Program Documentation 6-14 Rung Comments 6-18 D Data Types 5-4 Aliases 5-5 Data View 10-2 Documentation 10-7 Editing Entries 10-12 Entries 10-8 Options 10-4 I I/O Configuration 5-2 Importing 6-14 A Program 6-19 Element Documentation 6-22 Program Comments 6-24 Importing Projects 3-5 Input Element 2-15 DirectSOFT 5 User Manual, 1st Edition i-1 Index Insert Instructions 6-24 Install Software 2-3 Installing an Upgrade 2-4 Instruction Browser 5-8 Instruction Editor 5-6 PID View 7-12 PLC Modes 2-24 Power Flow 5-14 Primary Views 7-2 Product Key Code 2-4 Protocol and Node Address 9-4 L Ladder Palette 4-28, 5-8 Link Status 9-6 Link Wizard 9-2 R Rung comments 6-11 Rungs 5-21 Copying 5-23 Cut and Paste 5-25 Deleting 5-22 Merge 5-26 Selecting 5-21 M Menu Bar 5-10 Modem Setup 9-12 N New Project 3-4 Project Files 3-8 New Window 4-31 Nickname 10-17 Nicknames 6-6 Assign 6-6 Element 6-6 Source 6-7 S Saving the Program 2-18 Software License Agreement 2-5 Split Screen 4-30 Stage comments 6-12 Start a New Project 2-10 Ladder Palette 2-14 Tip of the day 2-11 Startup Issues B-3 Status Bar Components 4-19 Supported Cables A-2, A-4 Supported Protocols A-3, A-5 System Requirements 2-2 O Options Dialog 4-21, 6-2 Documentaion 6-3 Documentation Editor 6-4 Global Options 4-23 Ladder Options 4-22 Output Element 2-16 Override Bits 10-15 T Themes 4-27 Toolbar Components 4-2 Custom Toolbar 4-17 Debug Toolbar 4-15 Edit Toolbar 4-8 P Pause Bits 10-14 i-2 DirectSOFT 5 User Manual, 1st Edition Index File Toolbar 4-7 Help Toolbar 4-17 Offline Toolbar 4-2 Online Toolbar 4-5 PLC Diagnostics Toolbar 4-13 PLC Setup Toolbar 4-13 PLC Toolbar 4-12 Search Toolbar 4-9 Tools Toolbar 4-11 View Toolbar 4-10 Window Toolbar 4-16 Trap Monitor 10-25 U Usage Mode 7-10 USB-to-Serial Converters B-3 X XRef Query 7-8 XRef Toolbar 7-9 DirectSOFT 5 User Manual, 1st Edition i-3