Paradox Spectra 1728ex Programming Reference Manual

   EMBED

Share

Preview only show first 6 pages with water mark for full document please download

Transcript

System Programming Guide 1728: V2.4 1738: V2.4 Default Installer Code 0000 / 000000 (see section [281] on page 17) Default System Master Code 1234 / 123456 (see section [301] on page 17) How Do I Enter Programming Mode? 1. Press [ENTER]. 2. Enter your [INSTALLER CODE]. 3. Enter 3-digit [SECTION] you wish to program. 4. Enter required [DATA]. Decimal and Hexadecimal Programming Table What Do I See? Value or Action Values 1 to 9 A (hex only) B (hex only) C (hex only) D (hex only) E (hex only) F (hex only) Exit Without Saving Erase Current Digit Save Data (hex only) What Do I Press? 10-Zone LED [1] to [9] [0] [STAY] [BYP] [MEM] [TBL] / [TRBL] [PG] / [FNC1] [CLEAR] [FORCE] [ENTER] [1] to [9] [0 (10)] [STAY] [BYP] [MEM] [TBL] [PG] [ENTER] flashes 16-Zone LED [1] to [9] [10] [11] [12] [13] [14] [15] [ARM1] & [STAY1] flash LCD [1] to [9] 0 B C D E F “SECTION [ ]” Displays next digit or next section Advances to the next section Trouble Display Press the [TBL] or [TRBL] key to view the Trouble Display. Please note that the keypad can be programmed to emit a beep every 5 seconds whenever a new trouble condition has occurred. Press the [TBL] or [TRBL] key to stop the beeping. [1] - No Battery or Low Battery [2] - Wireless Transmitter Low Battery [3] - Power Failure [4] - Bell Output Disconnected [5] - Maximum Bell Current [6] - Maximum Auxiliary Current [7] - Communicator Report Failure [8] - Timer Loss** [9] - Tamper or Zone Wiring Failure* [10] - Telephone Line Monitoring Failure [11]/[STAY] - Fire Loop Trouble* [12]/[BYP] - Module Loss [13]/[MEM] - Wireless Transmitter Supervision Loss* [16]/[FORCE] and [TBL]/[TRBL] flashes - Keypad Fault * press the illuminated key ([9], [STAY] or [MEM]) to view which zones are causing the trouble. Enter the Installer Code to clear Tamper troubles. ** press [8] to re-program the time. Spectra 1728 & 1738 -1Programming Guide Table of Contents Default Installer Code.................................................................................................................................................................................... 1 Default System Master Code ........................................................................................................................................................................ 1 How Do I Enter Programming Mode? ........................................................................................................................................................... 1 Decimal and Hexadecimal Programming Table............................................................................................................................................ 1 Trouble Display ............................................................................................................................................................................................. 1 Data Display Mode (LED Keypads Only) ...................................................................................................................................................... 3 Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher)............................................................................................................. 3 Zone Programming ....................................................................................................................................................................................... 4 System Timers .............................................................................................................................................................................................. 6 Programmable Outputs ................................................................................................................................................................................. 7 System Options........................................................................................................................................................................................... 10 Communication Settings ............................................................................................................................................................................. 14 Report Codes .............................................................................................................................................................................................. 15 System Settings .......................................................................................................................................................................................... 17 User Code Options...................................................................................................................................................................................... 17 Reprogram All Modules............................................................................................................................................................................... 18 Paradox Memory Key (PMC-3) ................................................................................................................................................................... 18 Programming a Wireless Fire Zone ............................................................................................................................................................ 18 4-PGM Expansion Module.................................................................................................................... 19 Printer Module ...................................................................................................................................... 20 Voice-assisted Arm/Disarm Module...................................................................................................... 22 Wireless Module ................................................................................................................................... 23 Zone Expansion Modules ..................................................................................................................... 26 User Operation ..................................................................................................................................... 27 Appendix A - Ademco CID Report Code List (Prog.)............................................................................ 29 Appendix B - Ademco CID Report Code List (All Codes) ..................................................................... 30 Module Connections ............................................................................................................................. 32 Hardware Connections ......................................................................................................................... 36 WARNING: This equipment must be installed and maintained by qualified service personnel only. Spectra 1728 & 1738 -2- Programming Guide Data Display Mode (LED Keypads Only) View the section’s programming one digit at a time. Does not function with sections using Feature Select Programming. To access the Data Display Mode, press the [ENTER] key after entering a section and before entering any data. The three LEDs as indicated below will begin to flash indicating that you are in the Data Display Mode. Each time the [ENTER] key is pressed, the keypad will display the next digit in the current section and will continue through all the following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature Select Method. Press the [CLEAR] key at any time to exit the Data Display Mode. Configuring the 1686H, 1686V and 1689 Keypads (V2.0 or higher) The keypad’s zone number, EOL definition and tamper switch are programmed through the keypad’s programming mode. How Do I Configure The Keypad? 1. Press [ENTER]. 2. Enter your [INSTALLER CODE] (default: 0000 / 000000). 3. Press the [PG] (1686H/V) / [FNC1] (1689) key and hold it for 3 seconds. 4. Press the desired key ([1] to [3]. See below). 5. Press [ENTER] to exit programming mode. After two minutes, the keypad exits programming mode. Key [1] - Keypad Zone Selection (“Zone Programming” on page 4) Key [1] determines whether the keypad’s zone is Keypad Zone 1 or Keypad Zone 2. When key [1] is OFF (not illuminated), the keypad’s zone is Keypad Zone 1. When key [1] is ON (illuminated), the keypad’s zone is Keypad Zone 2. Key [1] OFF = Keypad Zone 1 (default) Key [1] ON = Keypad Zone 2 Key [2] - EOL Definition Key [2] determines the keypad zone’s EOL definition. When key [2] is OFF (not illuminated), EOL is disabled and the keypad zone uses the on-board EOL resistor. When key [2] is ON (illuminated), EOL is enabled and the keypad zone requires that an external EOL resistor be connected (refer to “Spectra 1728 PCB Layout” on page 38 and “Spectra 1738 PCB Layout” on page 39 for more details). Key [2] OFF = EOL disabled Key [2] ON = EOL enabled (default) Key [3] - On-Board Tamper Key [3] enables or disables the keypad’s on-board tamper switch. When key [3] is OFF (not illuminated), the tamper switch is disabled. When key [3] is ON (illuminated), the tamper switch is enabled. Key [3] OFF = On-board tamper switch disabled Key [3] ON = On-board tamper switch enabled The keypad can be ordered with or without a tamper switch. If the keypad has no tamper switch, key [3] will be OFF by default. If the keypad has a tamper switch, key [3] will be ON by default. Spectra 1728 & 1738 -3- Programming Guide Zone Programming When programming zones, the zone assignments are dependent on where the detection devices are connected to in the system. In installations that require using mostly the expansion inputs, refer to Reassign Keypad Zone 2 (section [126] option [7] on page 10) and Reassign Zones to Expansion Inputs (section [126] option [8] on page 10). The Expansion zones need to be enabled in order for Zone Programming to work. Refer to “Zone Expansion Modules” on page 26. Do not assign inputs from different modules to the same expansion input. Zone Recognition Table for 1728 Section [126] Option [7]: OFF Option [8]: OFF Control Panel Input 1 = Input 2 = Input 3 = Input 4 = Input 5 = Keypad Zone 1 = Zone 2 = Expansion Input 1 = Input 2 = Input 3 = Input 4 = Input 5 = Input 6 = Input 7 = Input 8 = Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 13 Zone 14 Zone 15 Zone 16 N/A N/A N/A N/A Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 N/A N/A N/A Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 6 Zone 7 Zone 8 Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 6 Zone 7 Zone 11 Zone 12 Zone 6 N/A Zone 11 N/A Zone 3 Zone 4 Zone 5 Zone 6 Zone 3 N/A Zone 5 N/A No ATZ Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 With ATZ Zones 1 & 6 Zones 2 & 7 Zones 3 & 8 Zones 4 & 9 Zones 5 & 10 Section [126] Option [7]: ON Option [8]: OFF No ATZ Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 With ATZ Zones 1 & 6 Zones 2 & 7 Zones 3 & 8 Zones 4 & 9 Zones 5 & 10 Section [126] Option [7]: OFF Option [8]: ON No ATZ Zone 1 Zone 2 N/A N/A N/A With ATZ Zones 1 & 3 Zones 2 & 4 N/A N/A N/A Section [126] Option [7]: ON Option [8]: ON No ATZ Zones 1 Zones 2 N/A N/A N/A With ATZ Zones 1 & 6 Zones 2 & 7 N/A N/A N/A = Not displayed on 10-Zone LED Keypads (1686H & 1686V) Section [126] option [7] = Reassign Keypad Zone 2 (see page 10) Section [126] option [8] = Reassign Zones to Expansion Inputs (see page 10) Zone Recognition Table for 1738 Section [126] Option [7]: OFF Control Panel Input 1 = Input 2 = Input 3 = Input 4 = Input 5 = Input 6 = Input 7 = Keypad Zone 1 = Zone 2 = Expansion Input 1 = Input 2 = Input 3 = Input 4 = Input 5 = Input 6 = Input 7 = Input 8 = Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 N/A N/A N/A N/A N/A N/A N/A N/A N/A Zone 9 Zone 10 Zone 11 Zone 12 Zone 13 Zone 14 Zone 15 Zone 16 Zone 16 N/A N/A N/A N/A N/A N/A N/A Zone 8 Zone 9 Zone 15 Zone 16 Zone 8 N/A Zone 15 N/A No ATZ Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 With ATZ Zone 1 & 8 Zone 2 & 9 Zone 3 & 10 Zone 4 & 11 Zone 5 & 12 Zone 6 & 13 Zone 7 & 14 Section [126] Option [7]: ON No ATZ Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 With ATZ Zone 1 & 8 Zone 2 & 9 Zone 3 & 10 Zone 4 & 11 Zone 5 & 12 Zone 6 & 13 Zone 7 & 14 Spectra 1728 & 1738 -4- Programming Guide How Do I Program the Zones? 1. Press the [ENTER] key. 2. Enter the [INSTALLER CODE] (Default: 0000 / 000000). 3. Enter 3-digit [SECTION]. 4. Enter one digit from the Zone Definition table. 5. Enter one digit from the Partition Assignment table. 6. Select one or more options from the Zone Options table. 7. Press the [ENTER] key. ZONE DEFINITION Empty - Zone Disabled 1 - Entry Delay 1 2 - Entry Delay 2 3 - Follow 4 - Instant 5 - 24 Hr. Burglary 6 - 24 Hr. Buzzer Additional definitions for onboard terminals: 7 - Keyswitch 8 - Fire 24 Hr 9 - Delayed Fire 24 Hr ZONE OPTIONS 1 - Auto Zone Shutdown 2 - Bypassable Zone 3 - Stay Zone 4 - 5 - Zone Alarm Type off off Audible alarm (steady) off on Audible alarm (pulsed) on off Silent alarm on on Generates a report only 6 - Intellizone 7 - Delay alarm transmission 8 - Force Zone KEYSWITCH OPTIONS 1 - off = Maintained on = Momentary 2 - off = Regular arm on = Stay arm Second Digit PARTITION ASSIGNMENT Empty - Zone Disabled 1 - Partition 1 2 - Partition 2 3 - Both Partitions [FORCE] key = empty First Digit Section [001] = Zone 01: [002] = Zone 02: [003] = Zone 03: [004] = Zone 04: [005] = Zone 05: [006] = Zone 06: [007] = Zone 07: [008] = Zone 08: [009] = Zone 09: [010] = Zone 10: [011] = Zone 11: [012] = Zone 12: [013] = Zone 13: [014] = Zone 14: [015] = Zone 15: [016] = Zone 16: Description Zone Definition Partition Assignment 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Zone Options 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 3 4 5 6 7 1 and 2 ON 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 8 Defaults = Empty Partition 1 Only the control panel’s on-board inputs can be defined as a Fire, Delayed Fire or a Keyswitch zone. In the 1728 the on-board zones are zones 01 to 05 and in the 1738 the on-board zones are zones 01 to 07. Spectra 1728 & 1738 -5Programming Guide System Timers Section # [050] [051] [052] [053] [054] [055] [056] [057] [058] [059] [060] [061] [062] [063] [064] [065] ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ Decimal Value (000 to 255) x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. x 10 msec. Description ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE ZONE SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED SPEED (ZONE 1) (ZONE 2) (ZONE 3) (ZONE 4) (ZONE 5) (ZONE 6) (ZONE 7) (ZONE 8) (ZONE 9) (ZONE 10) (ZONE 11) (ZONE 12) (ZONE 13) (ZONE 14) (ZONE 15) (ZONE 16) Default 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. 600 msec. If ATZ is enabled (section [132] option [5]), do not set the Zone Speed to less than 50msec. as this may cause false alarms. [066] [067] [068] [069] [070] [071] [072] [073] [074] [075] [076] [077] [078] [079] [080] [081] [082] [083] [084] [085] [086] [087] [088] [089] [090] [091] [092] [093] [094] [095] [110] [111] [112] ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ ___/___/___ seconds (000 = follow Deactivation Event) seconds (000 = follow Deactivation Event) seconds (000 = follow Deactivation Event) seconds seconds seconds seconds minutes (000 = no bell on alarm) minutes (000 = no bell on alarm) x 15 minutes (000 = disabled) x 15 minutes (000 = disabled) seconds (minimum 10 sec.) (000 = no answer, maximum = 15 rings) x 2 sec. (minimum 32 sec.) seconds (000 = 16, maximum = 16) seconds seconds seconds (minimum 10 sec.) seconds minutes days (000 = disabled) 000 to 127 = +1 to +127 seconds 128 to 255 = -1 to -127 seconds ___/___/___ (000 = disabled, maximum = 15) ___/___/___ minutes (000 = disabled) ___/___/___ (000 = disabled) ___/___/___ attempts before locking (000 = disabled) ___/___/___ minutes (000 = disabled) ___/___/___ seconds (000 = disabled) ___/___/___ days (000 = disabled) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) ___/___ : ___/___ hours (00 to 23) : minutes (00 to 59) PGM1 TIMER PGM2 TIMER GLOBAL PGM TIMER 1 2 EXIT DELAY 1* EXIT DELAY 2* BELL CUT-OFF TIMER (PARTITION 1)** BELL CUT-OFF TIMER (PARTITION 2)** NO MOVEMENT TIMER (PARTITION 1) NO MOVEMENT TIMER (PARTITION 2) ENTRY DELAY ENTRY DELAY ANSWERING MACHINE OVERRIDE DELAY NUMBER OF RINGS TLM FAIL TIMER DELAY ALARM TRANSMISSION MAXIMUM DIALING ATTEMPTS DELAY BETWEEN ATTEMPTS PAGER DELAY INTELLIZONE DELAY RECENT CLOSING DELAY POWER FAILURE REPORT DELAY AUTO TEST REPORT CLOCK ADJUST AUTO ZONE SHUTDOWN COUNTER RECYCLE ALARM DELAY 5 sec. 5 sec. 5 sec. 45 sec. 45 sec. 30 sec. 30 sec. 4 min. 4 min. Disabled Disabled Disabled 8 rings 32 sec. Disabled 8 attempts 20 sec. 5 sec. 48 sec. No delay 15 min. Disabled Disabled 5 Disabled RECYCLE ALARM COUNTER Disabled KEYPAD LOCKOUT Disabled KEYPAD LOCKOUT DELAY Disabled PANIC LOCKOUT TIMER Disabled CLOSING DELINQUENCY TIMER (PARTITION 1) Disabled AUTO TEST REPORT (TIME OF DAY) Disabled AUTO-ARM TIME (PARTITION 1) Disabled AUTO-ARM TIME (PARTITION 2) Disabled * Maximum 60 seconds for UL listed systems. ** 5 minutes minimum for cUL installations. Spectra 1728 & 1738 -6Programming Guide Programmable Outputs Each PGM Deactivation event can be used as another start (activation) event if their respective PGM timer (see sections [066] to [068]) is programmed with a value other than 000. Example: section [120] = 05 03 02: this means PGM1 will activate whenever partition 2 is Stay armed. Section # [120] [121] PGM 1 PGM Activation Event PGM 1 PGM Deactivation Event Event Group # Sub-Group # ___/___ ___/___ ___/___ ___/___ Partition # ___/___ ___/___ [122] [123] [124] [125] PGM 2 PGM Activation Event PGM 2 PGM Deactivation Event Global PGM Activation Event Global PGM Deactivation Event Used to activate PGMs on expansion modules & LCD keypads. ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ Event Group # 00 = Zone OK 01 = Zone Open 02 = Partition Status Sub-Group # 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 00 = System not ready (Partition 1 only) 01 = System ready (Partition 1 only) 02 = Steady Alarm in Partition 03 = Pulsed Alarm in Partition 04 = Pulsed or Steady Alarm in Partition 05 = Alarm in Partition Restored 06 = Bell Squawk Activated (Partition 1 only) 07 = Bell Squawk Deactivated (Partition 1 only) 08 = Ground start (Partition 1 only) 09 = Disarm Partition 10 = Arm Partition 11 = Entry Delay (breach when system is armed) 99 = Any Sub-Group 00 = Telephone Line Trouble (Partition 1 only) 01 = [PG] or [FNC1] key was pressed (Partition 1 only).This option can also be used to reset smoke detectors. 02 = Instant Arming 03 = Stay Arming 04 = Force Arming 05 = Fast Exit (Force & Regular Only) 06 = PC Fail to Communicate (Partition 1 only) 07 = Midnight (Partition 1 only) 99 = Any Sub-Group (Partition 1 only, except 02 to 05) 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control -7Programming Guide 05 = Non-Reportable Events 06 = Arm/Disarm with Remote Control 07 = Button Pressed on Remote (see button option “B” on page 24) 08 = Button Pressed on Remote (see button option “C” on page 24) Spectra 1728 & 1738 Event Group # 09 = Button Pressed on Remote (see button option “D” on page 24) 10 = Bypass Programming 11 = User Activated PGM 12 = Zone with Delay Transmission Option Enabled is Breached 13 = Arm with User Code 14 = Special Arm Sub-Group # 01 to 08 = Remote Controls 1 to 8 99 = Any Remote Control 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 (Partition 1 only) 99 = Any User Code 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 00 = Auto Arming (timed/no movement) 01 = Late to Close (Auto-Arming failed) 02 = No Movement Auto-Arming 03 = Partial Arming (Stay, Force, Instant, Bypass) 04 = One-Touch Arming 05 = Arm with WinLoad Software 07 = Closing Delinquency (Partition 1 only) 99 = Any Sub-Group 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 01 to 48 = User Code Numbers 001 to 048 99 = Any User Code 00 = Cancel Auto Arm (timed/no movement) 01 = Disarm with WinLoad Software 02 = Disarm after alarm with WinLoad Software 03 = Cancel Alarm with WinLoad Software 99 = Any Sub-Group 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 00 = Emergency Panic 01 = Auxiliary Panic 02 = Fire Panic 03 = Recent Closing 04 = Auto Zone Shutdown 05 = Duress Alarm 06 = Keypad Lockout 99 = Any Sub-Group 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone -8Programming Guide 15 = Disarm with User Code 16 = Disarm After Alarm w/ User Code 17 = Cancel Alarm with User Code 18 = Special Disarm 19 = Zone Bypassed on Arming 20 = Zone in Alarm 21 = Fire Alarm 22 = Zone Alarm Restore 23 = Fire Alarm Restore 24 = Special Alarm 25 = Auto Zone Shutdown 26 = Zone Tamper 27 = Zone Tamper Restore Spectra 1728 & 1738 Event Group # 28 = System Trouble Sub-Group # 01 = AC Loss: only after Power Failure Delay has elapsed (Partition 1 only) 02 = Battery Failure (Partition 1 only) 03 = Auxiliary current overload (Partition 1 only) 04 = Bell current overload (Partition 1 only) 05 = Bell disconnected (Partition 1 only) 06 = Timer Loss (Partition 1 only) 07 = Fire Loop Trouble (Partition 1 only) 08 = Future Use 09 = Module Fault (Partition 1 only) 10 = Printer Fault (Partition 1 only) 11 = Fail to Communicate (Partition 1 only) 99 = Any Sub-Group (Partition 1 only) 00 = TLM restore (Partition 1 only) 01 = AC Loss restore (Partition 1 only) 02 = Battery Failure restore (Partition 1 only) 03 = Auxiliary current overload restore (Partition 1 only) 04 = Bell current overload restore (Partition 1 only) 05 = Bell disconnected restore (Partition 1 only) 06 = Timer Programmed (Partition 1 only) 07 = Fire Loop Trouble restore (Partition 1 only) 08 = Future Use 09 = Module Fault restore (Partition 1 only) 10 = Printer Fault restore (Partition 1 only) 11 = Fail to Communicate restore (Partition 1 only) 99 = Any Trouble Restore (Partition 1 only) 00 = System Power Up (Partition 1 only) 01 = Test Report (Partition 1 only) 02 = WinLoad Software Access (Partition 1 only) 03 = WinLoad Software Access finished (Partition 1 only) 04 = Installer enters programming mode (Partition 1 only) 05 = Installer exits programming mode (Partition 1 only) 99 = Any Sub-Group (Partition 1 only) 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 1728: 01 to 05 = Zones 1 to 5 (on-board inputs) 1738: 01 to 07 = Zones 1 to 7 (on-board inputs) 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone 01 to 16 = Zones 1 to 16 99 = Any Zone Sub-Group # Partition # 29 = System Trouble Restore 30 = Special Reporting 31 = Wireless Transmitter Supervision Loss 32 = Wireless Transmitter Supervision Loss Restore 33 = Arming with a Keyswitch 34 = Disarming with a Keyswitch 35 = Disarm after Alarm with a Keyswitch 36 = Cancel Alarm with a Keyswitch 37 = Wireless Transmitter Low Battery 38 = Wireless Transmitter Low Battery Restore Event Group # 80 = PGM follows Clock (APR3-PGM4 only) HH = hour according to 24hr. clock MM = minutes according to 24hr. clock Spectra 1728 & 1738 -9Programming Guide System Options Bold = Default Setting SECTION [126]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] Confidential Mode To Exit Confidential Mode Confidential Mode Timer PGM1 Normal State PGM2 Normal State Global PGM Normal State Reassign Keypad Zone 2 Reassign Zones to Expansion Inputs* (1728 only) OR Zone 1 Becomes 2-wire Smoke Input (1738 only) OFF Disabled Enter Access Code 2 minutes Normally Open (N.O.) Normally Open (N.O.) Normally Open (N.O.) Disabled Disabled ON Enabled Press a Key 5 seconds Normally Closed (N.C.) Normally Closed (N.C.) Normally Closed (N.C.) Enabled Enabled * Reassign Zones to Expansion Inputs changes the zone numbering to increase the number of expansion inputs that can be displayed on 10-Zone LED Keypads. Refer to the 1728 & 1738 Reference & Installation Manual for details. SECTION [127]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] Partitioning Access Code Length Keypad Audible Trouble Warning Lock System Master Code Battery Charge Current (1738 only) User Code 048 is a Duress Code Alarm Relay follows (1738 only) ATZ Wiring Options (V2.4 or higher) OFF Disabled 6-digits Disabled Disabled 350mA Disabled Bell Output Series Wiring ON Enabled 4-digits Enabled Enabled 700mA Enabled Global PGM Parallel Wiring SECTION [128]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] Panic 1: Keys [1] & [3] Panic 2: Keys [4] & [6] Panic 3: Keys [7] & [9] Panic 1: Silent or Audible Panic 2: Silent or Audible Panic 3: Silent or Fire Keypad 1 Tamper Supervision Keypad 2 Tamper Supervision OFF Disabled Disabled Disabled Silent Silent Silent Disabled Disabled ON Enabled Enabled Enabled Audible Audible Fire Enabled Enabled SECTION [129]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] PGM2 Output Activation Option PGM2 Pulse Once Every 30sec if System Armed PGM2 Pulse On Arm, Twice On Disarm ZX4 & ZX8 Zone Expansion Module Supervision Wireless Module Supervision Wireless Module Low Battery Supervision 4-PGM Expansion Module Supervision (APR3PGM4) Printer Module Supervision (APR3-PRT1) Spectra 1728 & 1738 OFF Steady Disabled Disabled Disabled Disabled Disabled Disabled Disabled - 10 Programming Guide ON Pulse (flash) Enabled Enabled Enabled Enabled Enabled Enabled Enabled Bold = Default Setting SECTION [130]: Arming/Disarming Options Option [1] [2] [3] [4] [5] [6] [7] [8] One-Touch Regular Arming* One-Touch Stay Arming* One-Touch Force Arming* One-Touch Bypass Programming* Restrict Arming on Battery Failure Restrict Arming on Tamper Failure Bell Squawk on Arm/Disarm with Keypad Beep on Exit Delay OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled ON Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled SECTION [131]: Arming/Disarming Options Option OFF [1] Report Disarming Always [2] Regular Arming Switches to Force Arming* † Disabled [3] Bell Squawk on Arm/Disarm with Remote Control Disabled (must be enabled for UL installations) [4] No Exit Delay When Arming with a Remote Control Disabled [5] No Exit Delay Beeps and No Bell Squawk When Disabled Stay Arming [6] Restrict Arming On Wireless Transmitter Disabled Supervision Loss [7] Generate Supervision Loss if Detected on Yes Bypassed Wireless Zone [8] Future Use N/A ON Only after alarm Enabled Enabled Enabled Enabled Enabled No N/A SECTION [132]: Zone Options Option [1]&[2] [1] OFF OFF ON ON Tamper Recognition Options [2] OFF ON OFF ON OFF see table see table ON see table see table Disabled (default) When disarmed: GENERATES TROUBLE ONLY When armed: Follows Zone Alarm Types When disarmed: GENERATES SILENT ALARM When armed: Follows Zone Alarm Types When disarmed: GENERATES AUDIBLE ALARM When armed: Follows Zone Alarm Types [3] [4] [5] [6] [7]&[8] Generate Tamper if detected on Bypassed Zone EOL (end-of-line) Resistors ATZ Zone Doubling Report Zone Restore Wireless Transmitter Supervision Options [7] OFF OFF ON ON [8] OFF ON OFF ON Yes No EOL Disabled On Bell Cut-off see table see table No Use EOL Resistors Enabled On Zone Closure see table see table Disabled (default) When disarmed: GENERATES TROUBLE ONLY When armed: Follows Zone Alarm Types When disarmed: GENERATES SILENT ALARM When armed: Follows Zone Alarm Types When disarmed: GENERATES AUDIBLE ALARM When armed: Follows Zone Alarm Types * Not to be used with UL installations. † This cannot be done using a keyswitch. Force arming is not supported by keyswitches. Spectra 1728 & 1738 - 11 Programming Guide Bold = Default Setting SECTION [133]: Partition 1 Options Option [1] [2] [3] [4] [5] [6] [7] [8] Auto-Arm on Time Auto-Arm on No Movement Auto Arming = Regular or Stay* Switch to Stay Arming if no entry delay is opened Stay Arming with Delay Partition 1 (Delay = [070]) Future Use Future Use Future Use OFF Disabled Disabled Regular Arming Disabled Disabled N/A N/A N/A ON Enabled Enabled Stay Arming Enabled Enabled N/A N/A N/A SECTION [134]: Partition 2 Options Option [1] [2] [3] [4] [5] [6] [7] [8] Auto-Arm on Time Auto-Arm on No Movement Auto Arming = Regular or Stay* Switch to Stay Arming if no entry delay is opened Stay Arming with Delay Partition 2 (Delay = [070]) Future Use Future Use Future Use OFF Disabled Disabled Regular Arming Disabled Disabled N/A N/A N/A ON Enabled Enabled Stay Arming Enabled Enabled N/A N/A N/A SECTION [135]: Dialer Options Option [1]&[2] [1] OFF OFF ON ON Telephone Line Monitoring (TLM) Options [2] OFF ON OFF ON OFF see table see table ON see table see table TLM Disabled (default) TLM generates a trouble if armed TLM generates an audible alarm if armed Silent alarms become audible [3] [4] [5] [6] [7] [8] Reporting (Dialer) Dialing Method Pulse Ratio If armed, activate bell output on Com. Failure Future Use Future Use Disabled Pulse Dialing 1:2 Disabled N/A N/A Enabled Tone (DTMF) Dialing 1:1.5 Enabled N/A N/A * Not to be used with UL installations. Spectra 1728 & 1738 - 12 Programming Guide Bold = Default Setting SECTION [136]: Dialer Options Option [1] [2] [3] [4] [5] [6]&[7] Call Back WinLoad Automatic Event Buffer Transmission Contact I.D. Report Codes Alternate Dial If no dial tone is present Pager Reporting Format Dialer Options [6] OFF OFF ON ON [7] OFF ON OFF ON OFF Disabled Disabled Programmable Disabled Continue after 4 sec. see table see table ON Enabled Enabled All Codes (automatic) Enabled Hang-up after 16 sec. see table see table 1 call to pager or cellular telephone (default) 2 calls to pager or cellular telephone 3 calls to pager or cellular telephone 4 calls to pager or cellular telephone [8] Pager Format Transmits (V2.4 & higher) After Pager Delay in section [083] Immediately (Personal Dialing) SECTION [137]: Event Call Direction Option [1] [2] [3] [4] [5] [6] [7] [8] Call Telephone #1 for Arming/Disarming Report Codes Call Telephone #2 for Arming/Disarming Report Codes Call Telephone #1 for Alarm/Restore Report Codes Call Telephone #2 for Alarm/Restore Report Codes Call Telephone #1 for Tamper/Restore Report Codes Call Telephone #2 for Tamper/Restore Report Codes Future Use Future Use OFF Disabled Disabled Disabled Disabled Disabled Disabled N/A N/A ON Enabled Enabled Enabled Enabled Enabled Enabled N/A N/A SECTION [138]: Event Call Direction Option [1] [2] [3] [4] [5] [6] [7] [8] Call Telephone #1 for Trouble/Restore Report Codes Call Telephone #2 for Trouble/Restore Report Codes Call Telephone #1 for Special Report Codes Call Telephone #2 for Special Report Codes Future Use Future Use Future Use Future Use OFF Disabled Disabled Disabled Disabled N/A N/A N/A N/A ON Enabled Enabled Enabled Enabled N/A N/A N/A N/A Spectra 1728 & 1738 - 13 - Programming Guide Communication Settings Section # [140]* ___ / ___ TEL1 TEL2 REPORTING FORMATS* 1 = ADEMCO SLOW (1400HZ, 1900HZ, 10BPS) 2 = SILENT KNIGHT FAST (1400HZ, 1900HZ, 20BPS) 3 = SESCOA (2300HZ, 1800HZ, 20BPS) 4 = ADEMCO EXPRESS (DTMF 4+2) 5 = ADEMCO CONTACT ID (DEFAULT) ALSO, SEE OPTION [3] IN SECTION [136] 6 = PAGER FORMAT If hexadecimals (0 to FF) are used to program the report codes, verify that the pager also supports hexadecimals. If the pager does not support hexadecimals, use only the digits 0 to 9. [141] [142] [143] [144] ___/___/___/___ PANEL IDENTIFIER (WINLOAD SOFTWARE) ___/___/___/___ PC PASSWORD (WINLOAD SOFTWARE) ___/___/___/___ PARTITION ACCOUNT NUMBER 1 (For less than 4 digits, use the [FORCE] key to enter blanks.) ___/___/___/___ PARTITION ACCOUNT NUMBER 2 (For less than 4 digits, use the [FORCE] key to enter blanks.) [150] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ PC TELEPHONE NUMBER FOR WINLOAD SOFTWARE (32-digits, if less than 32 press [ENTER] to accept) [151] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ CENTRAL STATION TELEPHONE OR PAGER NUMBER 1 (32-digits, if less than 32 press [ENTER] to accept) __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ CENTRAL STATION TELEPHONE OR PAGER NUMBER 2 (32-digits, if less than 32 press [ENTER] to accept) [152] [153] __/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__/__ BACK UP TELEPHONE NUMBER (32-digits, if less than 32 press [ENTER] to accept) Special Keys for Telephone Numbers [STAY] = * [BYP] = # [MEM] = Switch from pulse to tone dialing or vice versa [TBL] or [TRBL] = 4-second pause [FORCE] = Delete current digit [PG] or [FNC1] = Inserts Blank Space * UL Note: The installer is required to verify the complete compatibility of the DAC Receiver and formats at least once per year. Spectra 1728 & 1738 - 14 - Programming Guide Report Codes Ademco Slow, Silent Knight, SESCOA, Ademco Express and Pager Formats: Enter the desired 1- or 2-digit hex-value (0-F or 00-FF). Ademco “Programmable” Format: Enter the desired 2-digit hex values from the “Ademco Report Code List - Programmable” (see Appendix A on page 29). Also Note that entering FF will set the report code to the default Ademco Report Code. Ademco “All Codes” Format: The control panel automatically generates report codes from the “Ademco Report Code List - All Codes” (see Appendix B on page 30). Arming Report Codes [160]___/___Access Code 01 ___/___Access Code 02 ___/___Access Code 03 ___/___Access Code 04 [161]___/___Access Code 05 ___/___Access Code 06 ___/___Access Code 07 ___/___Access Code 08 [162]___/___Access Code 09 ___/___Access Code 10 ___/___Access Code 11 ___/___Access Code 12 [163]___/___Access Code 13 ___/___Access Code 14 ___/___Access Code 15 ___/___Access Code 16 [164]___/___Access Code 17 ___/___Access Code 18 ___/___Access Code 19 ___/___Access Code 20 [165]___/___Access Code 21 ___/___Access Code 22 ___/___Access Code 23 ___/___Access Code 24 [166]___/___Access Code 25 ___/___Access Code 26 ___/___Access Code 27 ___/___Access Code 28 [167]___/___Access Code 29 ___/___Access Code 30 ___/___Access Code 31 ___/___Access Code 32 [168]___/___Access Code 33 ___/___Access Code 34 ___/___Access Code 35 ___/___Access Code 36 [169]___/___Access Code 37 ___/___Access Code 38 ___/___Access Code 39 ___/___Access Code 40 [170]___/___Access Code 41 ___/___Access Code 42 ___/___Access Code 43 ___/___Access Code 44 [171]___/___Access Code 45 ___/___Access Code 46 ___/___Access Code 47 ___/___Access Code 48 SPECIAL ARMING CODES [172]___/___Auto-Arming ___/___Late to Close ___/___No Movement ___/___Partial Arming [173]___/___Quick Arming ___/___Arming via PC ___/___Keyswitch Arming ___/___Closing Delinquency Disarming Report Codes [174]___/___Access Code 01 ___/___Access Code 02 ___/___Access Code 03 ___/___Access Code 04 [175]___/___Access Code 05 ___/___Access Code 06 ___/___Access Code 07 ___/___Access Code 08 [176]___/___Access Code 09 ___/___Access Code 10 ___/___Access Code 11 ___/___Access Code 12 [177]___/___Access Code 13 ___/___Access Code 14 ___/___Access Code 15 ___/___Access Code 16 [178]___/___Access Code 17 ___/___Access Code 18 ___/___Access Code 19 ___/___Access Code 20 [179]___/___Access Code 21 ___/___Access Code 22 ___/___Access Code 23 ___/___Access Code 24 [180]___/___Access Code 25 ___/___Access Code 26 ___/___Access Code 27 ___/___Access Code 28 [181]___/___Access Code 29 ___/___Access Code 30 ___/___Access Code 31 ___/___Access Code 32 [182]___/___Access Code 33 ___/___Access Code 34 ___/___Access Code 35 ___/___Access Code 36 [183]___/___Access Code 37 ___/___Access Code 38 ___/___Access Code 39 ___/___Access Code 40 Spectra 1728 & 1738 - 15 Programming Guide [184]___/___Access Code 41 ___/___Access Code 42 ___/___Access Code 43 ___/___Access Code 44 [185]___/___Access Code 45 ___/___Access Code 46 ___/___Access Code 47 ___/___Access Code 48 SPECIAL DISARMING CODES [186]___/___Cancel Auto-Arm ___/___Disarming via PC ___/___Keyswitch Disarm ___/___N/A Alarm Report Codes ALARM [187]___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04 [188]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08 [189]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12 [190]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___Zone 16 RESTORE [191]___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04 [192]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08 [193]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12 [194]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___Zone 16 SPECIAL [195]___/___Emergency Panic ___/___Auxiliary Panic ___/___Fire Panic ___/___Recent Closing [196]___/___Zone Shutdown ___/___Duress ___/___Keypad Lockout ___/___N/A Tamper Report Codes TROUBLE [197] ___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04 [198]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08 [199]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12 [200]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___Zone 16 RESTORE [201] ___/___Zone 01 ___/___Zone 02 ___/___Zone 03 ___/___Zone 04 [202]___/___Zone 05 ___/___Zone 06 ___/___Zone 07 ___/___Zone 08 [203]___/___Zone 09 ___/___Zone 10 ___/___Zone 11 ___/___Zone 12 [204]___/___Zone 13 ___/___Zone 14 ___/___Zone 15 ___/___Zone 16 System Trouble Report Codes SYSTEM TROUBLE [205]___/___N/A ___/___AC Failure ___/___Battery Failure ___/___Auxiliary Supply [206]___/___Bell Output Overload ___/___Bell Output Disconnect ___/___Timer Loss ___/___Fire Loop Trouble [207]___/___Wireless Low Battery ___/___Module Fault ___/___Printer Fault ___/___Fail to Communicate RESTORE [208]___/___TLM ___/___AC Failure ___/___Battery Failure ___/___Auxiliary Supply [209]___/___Bell Output Overload ___/___Bell Output Disconnect ___/___Timer Loss ___/___Fire Loop Trouble [210]___/___Wireless Low Battery ___/___Module Fault ___/___Printer Fault ___/___Fail to Communicate SPECIAL [211] ___/___Cold Start (Shutdown) ___/___Test Report ___/___N/A ___/___PC Exit [212]___/___Installer In ___/___Installer Out ___/___N/A ___/___N/A [213]___/___TX Supervision Loss ___/___TX Supervision Restore ___/___N/A ___/___N/A Spectra 1728 & 1738 - 16 - Programming Guide System Settings Section # [280] [281] [282] [301] ___/___:___/___ ___/___/___/___/___/___ ___/___/___ ___/___/___/___/___/___ SYSTEM REAL TIME CLOCK (HH:MM) INSTALLER CODE, DEFAULT: Description 0000 / 000000 000 (147 TO LOCK, 000 TO UNLOCK) 1234 / 123456 INSTALLER CODE LOCK, DEFAULT: SYSTEM MASTER CODE, DEFAULT: User Code Options System Master Code arms or disarms partitions using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions. Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. Default for all user codes is options [1], [3] and [4] ON. [1] ON = Partition 1 Access ON = Option Enabled [2] ON = Partition 2 Access OFF = Option Disabled [3] ON = Bypass Programming [4] ON = Stay Arming Section # [302] [303] [304] [305] [306] [307] [308] [309] [310] [311] [312] [313] [314] [315] [316] [317] [318] [319] [320] [321] [322] [323] [324] Master Code 1 Master Code 2 User Code 004 User Code 005 User Code 006 User Code 007 User Code 008 User Code 009 User Code 010 User Code 011 User Code 012 User Code 013 User Code 014 User Code 015 User Code 016 User Code 017 User Code 018 User Code 019 User Code 020 User Code 021 User Code 022 User Code 023 User Code 024 User Code Options (ON/OFF) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Section [325] [326] [327] [328] [329] [330] [331] [332] [333] [334] [335] [336] [337] [338] [339] [340] [341] [342] [343] [344] [345] [346] [347] [348] User Code 025 User Code 026 User Code 027 User Code 028 User Code 029 User Code 030 User Code 031 User Code 032 User Code 033 User Code 034 User Code 035 User Code 036 User Code 037 User Code 038 User Code 039 User Code 040 User Code 041 User Code 042 User Code 043 User Code 044 User Code 045 User Code 046 User Code 047 User Code 048 [5] ON = Force Arming [6] ON = Arm Only [7] ON = PGM Activation Only [8] ON = Future Use User Code Options (ON/OFF) 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Spectra 1728 & 1738 - 17 - Programming Guide Reprogram All Modules [750] After removing an expansion module from the communication bus, the control panel keeps the module’s programmed sections in memory. Therefore, if you add or replace a module you can re-program the module with the settings saved in the control panel. To do so, enter section [750] and press [ENTER]. The keypads will beep twice every second until the procedure is completed. Paradox Memory Key (PMC-3) [900] DOWNLOAD FROM PARADOX MEMORY KEY TO DESTINATION CONTROL PANEL. [902] COPY TO MEMORY KEY FROM SOURCE CONTROL PANEL. Download to DESTINATION Control Panel 1. Insert the Memory Key onto the serial connector labelled KEY on the Spectra control panel to which you wish to download the contents of the memory key to. 2. Re-apply AC and battery power. 3. Enter installer programming mode, enter section [900], then press [ENTER] to acknowledge. 4. When the keypad emits a confirmation beep, remove the Memory Key. 5. Enter section [750] to reprogram the modules with the information downloaded from the Paradox Memory Key. Copy to Memory Key from SOURCE Control Panel 1. Remove AC and battery power from the control panel. 2. Insert Memory Key onto the serial connector labelled KEY on the Spectra control panel that you want to copy. Make sure the write protect jumper of the Memory Key is on. 3. Re-apply AC and battery power. 4. Enter installer programming mode, enter section [902], then press [ENTER] to acknowledge. 5. When the keypad emits a confirmation beep, remove the Memory Key. Remove the Memory Key’s jumper if you do not wish to accidentally overwrite its contents. Write Protect Jumper Jumper On = Read from & write to memory key Jumper Off = Write protect (read from memory key only) Insert Paradox Memory Key onto the connector labelled “Key” Partial View: Spectra Series Control Panels Programming a Wireless Fire Zone With Spectra systems, fire zones cannot be assigned to expansion zones. As a result, when installing a wireless smoke detector to be used with a Spectra system, the corresponding zone must be programmed as follows: 1. The zone must be defined as a 24Hr Burglary zone. 2. The zone’s alarm type must be set to Audible Alarm (pulsed). 3. The zone’s Auto-Zone Shutdown (zone option [1]) and Bypass (zone option [2]) features must be disabled. 4. Change the zone’s report code from a burglary report code to a fire report code. If using Ademco Contact I.D., change the Contact ID Options from All Codes to Programmable (section [136] option [3] = OFF) and then enter the report code manually. Spectra 1728 & 1738 - 18 - Programming Guide 4-PGM Expansion Module Due to the APR3-PGM4’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), Digiplex DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PGM4 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PGM4 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting SECTION [500]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] PGM1 Time Base Selection PGM2 Time Base Selection PGM3 Time Base Selection PGM4 Time Base Selection Future Use Future Use Future Use Future Use OFF Seconds Seconds Seconds Seconds N/A N/A N/A N/A ON Minutes Minutes Minutes Minutes N/A N/A N/A N/A PGM Programming Each PGM Deactivation event can be used as another activation event if their respective PGM timer (see sections [501] to [504]) is programmed with a value other than 000. The APR3-PGM4 uses the same PGM events as the Spectra control panel, please refer to “Programmable Outputs” on page 7. Section # [501] ___/___/___ [502] ___/___/___ [503] ___/___/___ [504] ___/___/___ Decimal Value (000-255) (000 = follow deactivation event) (000 = follow deactivation event) (000 = follow deactivation event) (000 = follow deactivation event) Description PGM1 TIMER PGM2 TIMER PGM3 TIMER PGM4 TIMER Default Value 5 sec. 5 sec. 5 sec. 5 sec. Partition # ___/___ ___/___ Section # [505] PGM1 Activation Event [506] PGM1 Deactivation Event Event Group # Sub-Group # ___/___ ___/___ ___/___ ___/___ [507] PGM2 Activation Event [508] PGM2 Deactivation Event ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ [509] PGM3 Activation Event [510] PGM3 Deactivation Event ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ [511] PGM4 Activation Event [512] PGM4 Deactivation Event ___/___ ___/___ ___/___ ___/___ ___/___ ___/___ UL Note: The 4-PGM Expansion Module is not UL listed. Spectra 1728 & 1738 - 19 Programming Guide Printer Module Due to the APR3-PRT1’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), Digiplex DGP-848 or DGP-NE96 control panel. When connected to the bus, the APR3-PRT1 automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one APR3-PRT1 can be connected to each Spectra control panel. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting SECTION [550]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] Assigned to Partition 1 Assigned to Partition 2 PGM Normal State Print Arming and Disarming Events Print Alarm and Alarm Restore Events Print Tamper and Tamper Restore Events Print Trouble and Trouble Restore Events Print Special Events OFF Disabled Disabled Normally Open (N.O.) Disabled Disabled Disabled Disabled Disabled ON Enabled Enabled Normally Closed (N.C.) Automatically Automatically Automatically Automatically Automatically SECTION [551]: Automatic Zone Status Printing Option [1] [2] [3] [4] [5] [6] [7] [8] Print Status of Zone 1 Print Status of Zone 2 Print Status of Zone 3 Print Status of Zone 4 Print Status of Zone 5 Print Status of Zone 6 Print Status of Zone 7 Print Status of Zone 8 OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled ON Automatically Automatically Automatically Automatically Automatically Automatically Automatically Automatically SECTION [552]: Automatic Zone status Printing Option [1] [2] [3] [4] [5] [6] [7] [8] Print Status of Zone 9 Print Status of Zone 10 Print Status of Zone 11 Print Status of Zone 12 Print Status of Zone 13 Print Status of Zone 14 Print Status of Zone 15 Print Status of Zone 16 OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled ON Automatically Automatically Automatically Automatically Automatically Automatically Automatically Automatically Spectra 1728 & 1738 - 20 - Programming Guide Bold = Default Setting SECTION [553]: Serial and Parallel Port Setup Options Option [1] [2]&[3] Serial Port Baud Rate Settings [2] OFF ON OFF ON [3] OFF OFF ON ON APR-PRT1 1200 baud (default) 2400 baud 9600 baud 19200 baud APR3-PRT1 2400 baud (default) 9600 baud 19200 baud 57600 baud OFF Disabled see table see table ON Enabled see table see table [4] [5] [6] [7] [8] Parallel Port Off-line Status Ignored (parallel port only) Paper Empty Status Ignored (parallel port only) Printer Fault Status Ignored (parallel port only) Printer Busy Status Ignored (parallel port only) Disabled Disabled Disabled Disabled Disabled Enabled Enabled Enabled Enabled Enabled PGM Programming The PGM Deactivation event can be used as another activation event if the PGM Timer (section [554]) is programmed with a value other than 000. The APR3-PRT1 module uses the same PGM events as the Spectra control panel, please refer to “Programmable Outputs” on page 7 Section # Decimal Value (000-255) [554] ___/___/___ seconds (000 = follow deactivation event) Section # [555] PGM1 Activation Event [556] PGM1 Deactivation Event Description PGM1 TIMER Default Value 5 sec. Partition # ___/___ ___/___ Event Group # Sub-Group # ___/___ ___/___ ___/___ ___/___ Clock Programming For example, to enter the date March 26, 2000 you would enter 20 (century), 00 (year), 03 (month), and 26 (day). Section # [557] Value Year ___/___/___/___ Month ___/___ Day ___/___ Spectra 1728 & 1738 - 21 - Programming Guide Voice-assisted Arm/Disarm Module Due to InTouch’s Auto-recognition feature, it can be used with either the Spectra (V2.0 or higher), Digiplex DGP-848 or DGPNE96 control panel. When connected to the bus, InTouch automatically detects which control panel it is connected to and adjusts its internal communication parameters to function accordingly. Only one InTouch can be connected to each Spectra control panel. APR3-ADM2 can also be programmed using the WinLoad Software. Refer to the WinLoad Online Help for more information. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Section # [575] ___/___/___ [576] ___/___/___ [577] ___/___/___ Decimal Value (000-255) rings (000 = disabled) seconds (010-255, 000 = disabled) seconds/minutes (000 = disabled) Description NUMBER OF RINGS ANSWERING MACHINE OVERRIDE PGM TIMER Default Value 8 rings 000 005 Bold = Default Setting SECTION [578]: General Options Option [1] [2] [3] [4] [5] [6] [7] [8] Stand-alone Code Length Partitioned System PGM Output PGM Time in Future Use Future Use Future Use Future Use OFF 6-digits Disabled Disabled Seconds N/A N/A N/A N/A ON 4-digits Enabled Enabled Minutes N/A N/A N/A N/A Spectra 1728 & 1738 - 22 - Programming Guide Wireless Module Only one MG-RCV3 (Magellan) can be connected to each Spectra control panel. Do not cut, bend or alter MG-RCV3’s antenna and ensure that electrical wires do not cross over the antenna, as this may affect signal reception. Zone Assignment The serial number can be located on the inside of the transmitter or you can use the Serial Number Display feature (see page 24). Also, refer to “Zone Recognition Table for 1728” and “Zone Recognition Table for 1738” on page 4. Section # Serial # [601] ___/___/___/___/___/___= EXPANSION INPUT 1 [602] ___/___/___/___/___/___= EXPANSION INPUT 2 [603] ___/___/___/___/___/___= EXPANSION INPUT 3 [604] ___/___/___/___/___/___= EXPANSION INPUT 4 [605] ___/___/___/___/___/___= EXPANSION INPUT 5 [606] ___/___/___/___/___/___= EXPANSION INPUT 6 [607] ___/___/___/___/___/___= EXPANSION INPUT 7 [608] ___/___/___/___/___/___= EXPANSION INPUT 8 Bold = Default Setting SECTION [610]: General Options Option [1] [2] [3] - [5] [6] [7] [8] Wireless Transmitter Check-in Supervision* Check-in Supervision Base Time Interval (must be same as the transmitter’s jumper setting) Future Use PGM3 Deactivation PGM4 Deactivation Ignore Wireless Tamper Signal OFF Disabled 24 Hours N/A 2 second Timer 2 second Timer Ignores tamper signal ON Enabled 80 Minutes N/A Manually Manually Reports tamper signal * Section [610] option [1] Wireless Transmitter Check-in Supervision must be enabled (ON) for UL installations. Section # [615] Decimal Value (000-255) ___/___/___ (001-008 = expansion inputs 1-8) Description ON-BOARD TAMPER ZONE ASSIGN. Default Value 000 PGM Activation/Deactivation PGM1 is always enabled and is activated through the Magellan Remote Control (MG-REM1). Remote control button controls PGM1. A second 5A PGM relay output (PGM2) is available as an option. Remote control button controls PGM2 (optional). Press the appropriate button to activate the PGM that it controls. Section [610] options [6] and [7] determine how the respective PGM will deactivate. If the option is OFF, the activated PGM will automatically deactivate after 2 seconds. If the option is ON, each activated PGM can be deactivated only by pressing the appropriate button on an Magellan Remote Control that controls a PGM. For a diagram of the Magellan Remote Control, refer to “Button Options” on page 24. Spectra 1728 & 1738 - 23 - Programming Guide Serial Number Display Section # [630] Description Press the tamper switch of the Magellan Wireless Transmitter. The keypad will emit a confirmation beep. On LED keypads, press the [ENTER] key to view the digits one at a time. On LCD keypads, the first 3 digits of the serial number will appear. Press the [ENTER] key 3 times to view the next 3 digits. Continue activating the desired transmitters or press [CLEAR] to exit. Signal Strength Display Section # Description After entering the desired section, activate the Magellan transmitter by opening/closing the zone or by pressing the tamper switch. Always ignore the first reading as it won’t be accurate. An average reading of 3 and up is acceptable. LED Keypads: The keypad will illuminate numbers 1 to 8. LCD Keypads: The keypad will display from 1 to 8 characters on the screen. Display Signal Strength of Expansion Input 1 - Section [601] Display Signal Strength of Expansion Input 2 - Section [602] Display Signal Strength of Expansion Input 3 - Section [603] Display Signal Strength of Expansion Input 4 - Section [604] Display Signal Strength of Expansion Input 5 - Section [605] Display Signal Strength of Expansion Input 6 - Section [606] Display Signal Strength of Expansion Input 7 - Section [607] Display Signal Strength of Expansion Input 8 - Section [608] [631] [632] [633] [634] [635] [636] [637] [638] Remote Control User Assignment Section # [701] [702] [703] [704] [705] [706] [707] [708] Decimal Value ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) ___/___/___(001-048 = user #) Description remote control #1 - section [721]/[731]* remote control #2 - section [722]/[732]* remote control #3 - section [723]/[733]* remote control #4 - section [724]/[734]* remote control #5 - section [725]/[735]* remote control #6 - section [726]/[736]* remote control #7 - section [727]/[737]* remote control #8 - section [728]/[738]* Default Value 000 000 000 000 000 000 000 000 * refer to “Remote Control Assignment” on page 25 and the MG-RCV3 Reference & Installation Manual. Button Options Button Options Table * Empty Slot [FORCE] - Button disabled 1 - Regular Arming 2 - Stay Arming 3 - Instant Arming 4 - Force Arming 5 - Disarm 6 - Disarm when no alarm 7 - Regular Arm and Disarm 8 - Panic 1 9 - Panic 2 A - Panic 3 B - PGM Activation (Event Group #7, see PGM Programming) C - PGM Activation (Event Group #8, see PGM Programming) D - PGM Activation (Event Group #9, see PGM Programming) NOTE: When using the Magellan remote control (MG-REM1), regardless of what is programmed for the button, pressing button C will activate PGM1 while pressing button D will activate PGM2. * Only arming and disarming button functions were investigated by UL. Spectra 1728 & 1738 - 24 Programming Guide Remote Control Button Programming RC# 1 2 3 4 5 6 7 8 Section [711] [712] [713] [714] [715] [716] [717] [718] RC Buttons Default: ( 1 5 0 0 0 0 0 0 ) ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + ______/_____/_____/_____/______/_____/_____/______ + + + + Please note that the User Code assigned to the remote control (sections [701] to [708]) must have the same User Options and Button Options enabled. For example, if you enable the Force Arming button option you must enable the appropriate Force Arming user option. Also, if you enable any of the Panic button options, you must enable the Panic options in the control panel. Remote Control Assignment If you have a Spectra control panel that is V2.0 or higher, you can use the Automatic Learning Method to assign your remote control(s). If you have a Spectra control panel that is V1.23 or lower, see the MG-RCV3 Reference & Installation Manual for how to program your remote control(s). Automatic Learning Method Enter the appropriate section and press any button on a Magellan remote control (MG-REM1) once, or until the confirmation beep sounds (“Beep-Beep-Beep-Beep-Beep”), to assign the remote control. If you hear a rejection beep, an error has occurred or the remote control has already been assigned. To delete a remote control, enter the appropriate section and then press the [FORCE] button. Section # [731] [732] [733] [734] [735] [736] [737] [738] Remote Control #1 #2 REMOTE CONTROL #3 REMOTE CONTROL #4 REMOTE CONTROL #5 REMOTE CONTROL #6 REMOTE CONTROL #7 REMOTE CONTROL #8 REMOTE CONTROL REMOTE CONTROL Spectra 1728 & 1738 - 25 - Programming Guide Zone Expansion Modules Only one SPC/APR3-ZX4 or one SPC/APR3-ZX8 can be connected to each Spectra control panel. The following sections are for SPC-ZX4 version 1.0, APR3-ZX4 version 1.0, SPC-ZX8 version 1.0 and APR3-ZX8 version 2.0. Modules with the APR- prefix are compatible with Spectra (versions 2.0 and higher) and DGP-848. Modules with the APR3- prefix are compatible with Spectra (versions 2.0 and higher), DGP-848 and DGP-NE96. Bold = Default Setting SECTION [650]: Options Option [1] [2] [3] [4]-[8] EOL (end-of-line) Resistors for hardwire modules Zone Expansion Module Tamper Recognition PGM1 on SPC/APR3-ZX8 follows Global PGM programmed in sections [124] & [125] Future Use OFF No EOL Disabled Disabled N/A ON Use EOL Resistors Z1 becomes tamper input Enabled N/A SECTION [651]: Zone Assignment Option [1] [2] [3] [4] [5] [6] [7] [8] See “Zone Recognition Table for 1728” on page 4. Input Z1 =Expansion Input 1 Input Z2 =Expansion Input 2 Input Z3 =Expansion Input 3 Input Z4 =Expansion Input 4 Input Z5 (SPC/APR3-ZX8 only) =Expansion Input 5 Input Z6 (SPC/APR3-ZX8 only) =Expansion Input 6 Input Z7 (SPC/APR3-ZX8 only) =Expansion Input 7 Input Z8 (SPC/APR3-ZX8 only) =Expansion Input 8 OFF Disabled Disabled Disabled Disabled Disabled Disabled Disabled Disabled ON Enabled Enabled Enabled Enabled Enabled Enabled Enabled Enabled PGM Programming (SPC-ZX8 and APR3-ZX8 Only) The PGM will only activate or deactivate 100mS after the selected event occurs. The PGM Deactivation event can be used as another activation event if the PGM Timer (section [655]) is programmed with a value other than 000. The system will ignore the PGM if it has been programmed to follow the Global PGM (option [3] in section [650]). Only PGM events from the table below can be used. Section # Decimal Value (000-255) [655] ___/___/___ seconds (000 = follow deactivation event) Section # [656] PGM1 Activation Event [657] PGM1 Deactivation Event Event Group # For SPC-ZX8: 60 = Hardwire Zone Opened 61 = Hardwire Zone Closed 62 = Hardwire Tamper Opened 63 = Hardwire Tamper Closed For APR3-ZX8: 60 = Hardwire Zone/Hardwire Tamper Opened 61 = Hardwire Zone/Hardwire Tamper Closed Description PGM1 TIMER Default Value 5 sec. Partition # ___/___ ___/___ Partition # Not used; enter 00 Event Group # Sub-Group # ___/___ ___/___ ___/___ ___/___ Sub-Group # 01 = Expansion Input 1 - Section [651] - [1] 02 = Expansion Input 2 - Section [651] - [2] 03 = Expansion Input 3 - Section [651] - [3] 04 = Expansion Input 4 - Section [651] - [4] 05 = Expansion Input 5 - Section [651] - [5] 06 = Expansion Input 6 - Section [651] - [6] 07 = Expansion Input 7 - Section [651] - [7] 08 = Expansion Input 8 - Section [651] - [8] 99 = Any zone expansion module input UL Note: The Zone Expansion Modules are not UL listed. Spectra 1728 & 1738 - 26 Programming Guide User Operation Partitioning The Spectra system is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can be used in installations where shared security systems are more practical, such as an office/warehouse building. If the system is not partitioned, all User Codes and features will be recognized as belonging to Partition 1. How does a partitioned system work? • Users can only arm or disarm their assigned partitions. • Only zones assigned to Partition 1 will arm or disarm when Partition 1 is armed or disarmed. • Only zones assigned to Partition 2 will arm or disarm when Partition 2 is armed or disarmed. • Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms. • Some of the system’s features can be programmed separately for each partition. Programming Access Codes User Access Codes are personal identification numbers that allow users to enter certain programming modes, arm or disarm the alarm system as well as activate or deactivate PGMs. Spectra security systems support the following: System Master Code can arm or disarm any partition using any arming method and can create, modify or delete any User Access Code. Only the System Master Code can modify or delete User Access Codes assigned to both partitions. Master Code 1 is permanently assigned to partition 1 and can be used to create, modify or delete User Access Codes that are assigned to partition 1. Master Code 2 is permanently assigned to partition 2 (except when partitioning is disabled, Master Code 2 will be assigned to partition 1) and can be used to create, modify or delete User Access Codes that are assigned to the same partition. 45 User Access Codes (including 1 Duress code) How Do I Program Access Codes? 1. Press [ENTER] 2. Key in the [SYSTEM MASTER CODE] or [MASTER CODE] 3. Key in 3-digit [SECTION] (see User Code Table) 4. Key in new 4- or 6-digit [ACCESS CODE] [ENTER] flashes. Return to step 3 How Do I Delete Access Codes? 1. Repeat steps 1 to 3 (see above) 2. Press the [FORCE] key once for each digit in the access code (4 or 6 times) until the keypad emits a Confirmation Beep. User Code Table Section [001] [002] [003] [004] TO [047] [048] User Codes User Code 001 = System Master Code User Code 002 = Master Code 1 User Code 003 = Master Code 2 User Code 004 to User Code 047 User Code 048 or Duress Code Spectra 1728 & 1738 - 27 - Programming Guide Programming Chime Zones This feature allows users to program which zones will be Chime Enabled. A Chime Enabled zone will cause the keypad to emit a rapid intermittent beep tone (BEEP-BEEP-BEEP-BEEP) advising the user every time it is opened. Each keypad must be Chime Programmed separately. Keypad chimes must be re-programmed if the system suffers a total power loss. 10-ZONE LED KEYPAD: Press and hold any key from [1] to [10] for 3 seconds to activate or deactivate Chiming for zones 1 to 10. For example, press and hold the [1] key to enable chiming on zone 1. If, after pressing and holding a key, the keypad emits a confirmation beep, this means the chime feature has been enabled for that zone. If the keypad emits a Rejection Beep, this means the Chime feature has been disabled for the corresponding zone. 16-ZONE LED KEYPAD: Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s). When the corresponding LED is on, the zone is chimed. When the corresponding LED is off, the zone is unchimed. When the desired zones are chimed, press [ENTER]. LCD KEYPAD: Press and hold the [9] key. Enter the 2-digit (01 to 16) zone number(s) or use the arrow keys to scroll through the zones. When the appropriate zone is displayed, press the [FNC1] key. When the desired zones are chimed, press [ENTER]. Keypad Muting Press and hold the [CLEAR] key for 3 seconds to enable or disable keypad muting. When muted, the keypad will only beep when a key is pressed or when the keypad emits a Rejection or Confirmation Beep. All other beep functions are disabled. Keypad Backlight (1686H and 1686V Only) The illumination level behind the keys can be modified to suit the user’s needs. There are four backlight levels. The [MEM] key is used to set the desired level. Each consecutive push of the [MEM] key will increase the backlight level until the maximum level is reached. After reaching the maximum level, the backlight level will return to the lowest level and the whole process is repeated. To change the backlight level: How do I Modify The Backlight? 1. Press and hold the [MEM] key for 3 seconds 2. The [MEM] key will illuminate 3. Press the [MEM] key to set the desired backlight level 4. Press [CLEAR] or [ENTER] to exit Installer Function Keys INSTALLER TEST MODE [ENTER] + [INSTALLER CODE] + [TBL] or [TRBL] The Installer Test Mode allows you to perform walk tests where the bell/siren will squawk once to indicate an open zone and twice to indicate a closed zone. To enter this mode, press [ENTER] + [INSTALLER CODE] + [TBL] or [TRBL]. The keypad will emit a Confirmation Beep. To disable this mode, press the [TBL] or [TRBL] key again. The keypad will emit a Rejection Beep. TEST REPORT [ENTER] + [INSTALLER/MASTER CODE] + [MEM] Sends the “Test Report” report code programmed in section [211] to the central station. CALL WINLOAD SOFTWARE [ENTER] + [INSTALLER/MASTER CODE] + [BYP] This feature is used to establish communication between the control panel and a computer using the WinLoad Software. After entering this mode, the control panel will dial the telephone number programmed in section [150]. CANCEL COMMUNICATION [ENTER] + [INSTALLER/MASTER CODE] + [STAY] Cancels all communication until the next reportable event. If the Master Code was used, only communication with WinLoad would be cancelled. ANSWER WINLOAD SOFTWARE [ENTER] + [INSTALLER/MASTER CODE] + [FORCE] Forces the control panel to pick-up an incoming telephone call. Spectra 1728 & 1738 - 28 Programming Guide Appendix A - Ademco CID Report Code List (Prog.) If using the Ademco Contact ID Programmable code format, enter the 2-digit hexadecimal value from the table below (Prog. Value) into sections [160] to [213] to program the desired report codes. To enter a 0 value press the [FORCE] key. CID# Reporting Code Prog. Value CID# Reporting Code Prog. Value CID# Reporting Code Prog. Value 5D 5E 5F 60 61 62 63 64 65 66 67 68 69 6A MEDICAL ALARMS - 100 100 Medical Alarm 01 101 Pendant Transmitter 02 102 Fail to Report In 03 FIRE ALARMS - 110 110 Fire Alarm 04 111 Smoke 05 112 Combustion 06 113 Water Flow 07 114 Heat 08 115 Pull Station 09 116 Duct 0A 117 Flame 0B 118 Near Alarm 0C PANIC ALARMS - 120 120 Panic Alarm 0D 121 Duress 0E 122 Silent 0F 123 Audible 10 BURGLAR ALARMS - 130 130 Burglary 11 131 Perimeter 12 132 Interior 13 133 24-Hour 14 134 Entry/Exit 15 135 Day/Night 16 136 Outdoor 17 137 Tamper 18 138 Near Alarm 19 GENERAL ALARMS - 140 140 General Alarm 1A 141 Polling Loop Open 1B 142 Polling Loop Short 1C 143 Expansion Module Failure 1D 144 Sensor Tamper 1E 145 Expansion Module Tamper 1F 24-HOUR NON-BURGLARY - 150 & 160 150 24-Hour Non-Burglary 20 151 Gas Detected 21 152 Refrigeration 22 153 Loss of Heat 23 154 Water Leakage 24 155 Foil Break 25 156 Day Trouble 26 157 Low Bottled Gas Level 27 158 High Temp 28 159 Low Temp 29 161 Loss of Air Flow 2A FIRE SUPERVISORY - 200 & 210 200 Fire Supervisory 2B 201 Low Water Pressure 2C 202 Low CO2 2D 203 Gate Valve Sensor 2E 204 Low Water Level 2F 205 Pump Activated 30 206 Pump Failure 31 SYSTEM TROUBLES - 300 & 310 300 System Trouble 32 301 AC Loss 33 302 Low System Battery 34 303 RAM Checksum Bad 35 304 ROM Checksum Bad 36 305 System Reset 37 306 Panel Program Changed 38 307 Self-Test Failure 39 308 System Shutdown 3A 309 Battery Test Failure 3B 310 Ground Fault 3C SOUNDER/RELAY TROUBLES - 320 320 Sounder Relay 3D 321 Bell 1 3E 322 Bell 2 3F 323 Alarm Relay 40 324 Trouble Relay 41 325 Reversing 42 SYSTEM PERIPHERAL TROUBLES - 330 & 340 330 System Peripheral 43 331 Polling Loop Open 44 332 Polling Loop Short 45 333 Exp. Module Failure 46 334 Repeater Failure 47 335 Local Printer Paper Out 48 336 Local Printer Failure 49 COMMUNICATION TROUBLES - 350 & 360 350 Communication 4A 351 Telco Fault 1 4B 352 Telco Fault 2 4C 353 Long Range Radio 4D 354 Fail to Communicate 4E 355 Loss of Radio Supervision 4F 356 Loss of Central Polling 50 PROTECTION LOOP TROUBLES - 370 370 Protection Loop 51 371 Protection Loop Open 52 372 Protection Loop short 53 373 Fire Trouble 54 SENSOR TROUBLES - 380 380 Sensor Trouble 55 381 Loss of Super. -RF 56 382 Loss of Super. - RPM 57 383 Sensor Tamper 58 384 RF xmtr. Low Battery 59 OPEN/CLOSE - 400 400 Open/Close 5A 401 O/C by User 5B 402 Group O/C 5C 403 Automatic O/C 404 Late to O/C 405 Deferred 406 Cancel 407 Remote Arm/Disarm 408 Quick Arm 409 Keyswitch O/C REMOTE ACCESS - 410 411 Callback Request Made 412 Success - Download Access 413 Unsuccessful Access 414 System Shutdown 415 Dialer Shutdown ACCESS CONTROL - 420 421 Access Denied 422 Access Report By User SOUNDER RELAY DISABLES - 520 520 Sounder/Relay Disabled 521 Bell 1 Disable 522 Bell 2 Disable 523 Alarm Relay Disable 524 Trouble Relay Disable 525 Reversing Relay Disable 6B 6C 6D 6E 6F 70 COMMUNICATION DISABLES - 550 & 560 551 Dialer Disabled 71 552 Radio xmitter Disabled 72 BYPASSES - 570 570 Zone Bypass 73 571 Fire Bypass 74 572 24-Hour Zone Bypass 75 573 Burg. Bypass 76 574 Group Bypass 77 TEST/MISC. - 600 601 Manual Trigger Test 78 602 Periodic Test Report 79 603 Periodic RF Xmission 7A 604 Fire Test 7B 605 Status Report to Follow 7C 606 Listen-in to Follow 7D 607 Walk Test Mode 7E 621 Event Log Reset 7F 622 Event Log 50% Full 80 623 Event Log 90% Full 81 624 Event Log Overflow 82 625 Time/Date Reset 83 626 Time/Date Inaccurate 84 627 Program Mode Entry 85 628 Program Mode Exit 86 631 Exception Schedule Change 87 654 System Inactivity 88 Spectra 1728 & 1738 - 29 - Programming Guide Appendix B - Ademco CID Report Code List (All Codes) System Event Arming with Master Code (##) Arming with User Code (##) Arming with Keyswitch (##) Auto Arming Arm with PC software Late To Close No Movement Partial arming Quick arming Delinquency Disarm with Master Code (##) Disarm with User Code (##) Disarm with Keyswitch (##) Disarm after alarm with Master Code (##) Disarm after alarm with User Code (##) Disarm after alarm with Keyswitch (##) Auto Arming Cancellation Disarm with PC software Disarm after an alarm with PC software Zone Bypassed (##) Zone alarm (##) Fire alarm (##) Zone alarm restore (##) Fire alarm restore (##) Panic 1 - Emergency Panic 2 - Medical Panic 3 - Fire Recent closing Global zone shutdown Duress alarm Zone shutdown (##) Zone tampered (##) Zone tamper restore (##) AC Failure Battery Failure Auxiliary supply trouble Spectra 1728 & 1738 Default Contact ID Report Code when option [3] is on in section [136] 3 4A1 - Close by user 3 4A1 - Close by user 3 4A9 - Keyswitch Close 3 4A3 - Automatic Close 3 4A7 - Remote arm/disarm 3 4A4 - Late to Close 3 4A4 - Late to Close 1 574 - Group bypass 3 408 - Quick arm 1 654 - Inactivity 1 4A1 - Open by user 1 4A1 - Open by user 1 4A9 - Keyswitch Open 1 4A1 - Open by user 1 4A1 - Open by user 1 4A9 - Keyswitch Open 1 4A5 - Deferred Open/Close 1 4A7 - Remote arm/disarm 1 4A7 - Remote arm/disarm 1 57A - Zone bypass 1 13A - Burglary Alarm 1 11A - Fire alarm 3 13A - Burglary Alarm Restore 3 11A - Fire alarm Restore 1 12A - Panic alarm 1 1AA - Medical alarm 1 115 - Pull Station 3 4AA - Open/Close 1 574 - Group bypass 1 121 - Duress 1 57A - Zone bypass 1 144 - Sensor tamper 3 144 - Sensor tamper restore 1 3A1 - AC loss 1 3A9 - Battery test failure 1 3AA - System trouble - 30 Programming Guide System Event Bell output current limit Bell absent Clock lost Fire loop trouble Wireless Transmitter Low Battery Wireless Transmitter Supervision Loss Module fault Printer fault Fail to communicate with monitoring station TLM trouble restore AC Failure restore Battery Failure restore Auxiliary supply trouble restore Bell output current limit restore Bell absent restore Clock programmed Fire loop trouble restore Wireless Transmitter Low Battery Wireless Transmitter Supervision Loss Module fault restore Printer fault restore Fail to communicate with monitoring station Cold Start Test Report engaged PC software communication finished Installer on site Installer programming finished Default Contact ID Report Code when option [3] is on in section [136] 1 321 - Bell 1 1 321 - Bell 1 1 626 - Time/Date inaccurate 1 373 - Fire trouble 1 384 - RF xmtr. low battery 1 381 - Loss of super. - RF 1 333 - Expansion module failure 1 336 - Local printer failure 1 354 - Fail to communicate 3 351 - Telco 1 fault restore 3 3A1 - AC loss restore 3 3A9 - Battery test restore 3 3AA - System trouble restore 3 321 - Bell 1 restore 3 321 - Bell 1 restore 3 626 - Time/Date Reset 3 373 - Fire trouble restore 3 384 - RF xmtr. low battery 3 381 - Loss of super. - RF 3 333 - Expansion module failure restore 3 336 - Local printer failure restore 3 354 - Fail to communicate restore 1 3A8 - System shutdown 1 6A2 - Periodic test report 1 412 - Successful - download access 1 627 - Program mode Entry 1 628 - Program mode Exit Spectra 1728 & 1738 - 31 - Programming Guide Module Connections Printer Module (APR3-PRT1) Press the "print test" switch to perform a print test RX LED reserved for future use Spectra Control Panel V2.0 or higher Not used Communication Bus DB-9 Serial Port Pin-out Diagram Pin 5 - GND Pin 4 - DTR (Data Terminal Ready / Not Used) Pin 8 - CTS (Control Transmission / Not Used) Pin 3 - TX Pin 2 - RX (Not Used) Connecting the PGM Output A Green “Locate” LED: Remains illuminated during power up B Red “Watchdog” LED: Flashes to indicate proper operation. If there is a communication failure, the red LED will flash ON for one second and OFF for one second. C Red “TX” LED: Flashes when the Printer Module is transmitting data through the serial port only. D 25-Pin Parallel Port: Connect the Printer Module’s 25-pin parallel port to any dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns. E 9-Pin Serial Port: Connect the Printer Module’s 9-Pin serial port to a dot matrix printer. Note: The dot matrix printer must support a minimum of 80 columns. F 9-Pin Serial Port: Connect the Printer Module’s 9-pin serial port to a computer’s COM port to view the control panel’s events on the computer’s monitor. The events displayed on the monitor can then be printed through the printer connected to the computer. Remove AC power and battery before adding APR3-PRT1 to the system. Do not connect any modules more than 76m (250 ft) from the control panel. Only one Printer Module can be connected per Spectra control panel. Spectra 1728 & 1738 - 32 - Programming Guide 4-PGM Expansion Module (APR3-PGM4) Red “Watchdog” LED: Status: flashes once per second to indicate proper operation. Flash 1 second on and 1 second off: The module is experiencing a communication failure with the control panel. Spectra control panel Not used External Power Supply (Recommended: Paradox PSW817 1.75A Switching Power Supply) Communication Bus Any device such as a garage door opener, light or siren Remove AC and battery from the control panel before adding the 4-PGM Output Module to the system. Do not connect the APR3PGM4 more than 76m (250 ft) from the control panel. Only one APR3-PGM4 can be connected per Spectra control panel. 4-Zone Expansion Module (SPC-ZX4 and APR3-ZX4) Not used Red “WDG” LED: Status: Flashes to indicate proper operation. Toggle 1 sec. on & 1 sec. off = Trouble and/or communication failure. Connecting the Tamper Switch Not used Spectra Control Panel Communication Bus Connect the detection devices to the module's input terminals exactly as shown in the Spectra Reference & Installation Manual. External Tamper Switch (N.C.) Input terminal Z1 can be used as a tamper switch input Option [2]: Section [650] Remove AC and battery power from the control panel before connecting the module to the communication bus. Do not connect the APR3-ZX4 or SPC-ZX4 more than 76m (250 ft) from the control panel. Only one APR3-ZX4 or one SPC-ZX4 can be connected per Spectra control panel. Spectra 1728 & 1738 - 33 - Programming Guide Voice-Assisted Arm/Disarm Module (APR3-ADM2) Remove AC and battery power from the control panel before adding the APR3-ADM2 module to the system. Do not connect the APR3ADM2 more than 76m (250 ft) from the control panel. Only one APR3-ADM2 can be connected per Spectra control panel. Green "PULSE"LED: Monitors the dialer. The LED will illuminate when the dialer is in use. When the dialer is not being used, the LED will remain off. Red “WATCHDOG” LED: Flashes once every second = normal. Toggle 1 second on & 1 second off = trouble and/or communication failure. Not Used Communication Bus Ground clamp Cold water pipe grounding Refer to Inset 1 To Spectra control panel Household telephone Partial view of Spectra control panel dialer. Inset 1: Connecting the APR3-ADM2 PGM Output To reset the standalone code of the APR3-ADM2 you have to perform a hardware reset of the Spectra control panel. Partial view of the APR3-ADM2 External Power Supply (Recommended: Paradox PSW817 1.75A Switching Power Supply) Any device such as a garage door opener, light or siren Spectra 1728 & 1738 - 34 - Programming Guide 8-Zone Expansion Modules (SPC-ZX8 and APR3-ZX8) NOT USED Red “WDG” LED: FLASH ONCE EVERY SEC. = normal. TOGGLE 1 SEC. ON & 1 SEC. OFF = Trouble and/or communication failure. Connecting the PGM output INSET 2 MR3-UL NOT USED INSET 1 Refer to the appropriate Spectra Reference & Installation Manual about connecting devices to the Expansion Input Terminals. Tamper Switch Connection External Tamper Switch (N.C.) Remove AC power and battery before adding a module to the system. Do not connect the APR3-ZX8 or SPC-ZX8 more than 76m (250 ft) from the control panel. Only one SPC-ZX8 or APR3-ZX8 can be connected per Spectra control panel. COMMUNICATION BUS Spectra Control Panel Input terminal Z1 can be used as a tamper switch input. Option [2]: Section [650] Magellan Wireless Expansion Module (MG-RCV3) Spectra 1728 & 1738 - 35 - Programming Guide Hardware Connections Single Zone Inputs Double Zone Inputs (with ATZ option only) Spectra 1728 & 1738 - 36 - Programming Guide Connecting Fire Circuits, Keyswitches and PGMs Program the PGM with the “[PG]/[FNC1] Key was pressed” Activation Event so that the smoke detectors can be reset by pressing the [PG] or [FNC1] key. See Event Group # 5 on page 7. All 4-wire smoke detectors must be connected using the daisy chain configuration Each Spectra 1738 control panel supports a maximum of five 2-wire smoke detectors PGM2 can be used as a strobe output (see section [129] options [1] to [3] on page 10). Alarm Relay (1738 only) Control Panel COM N.C. N.O. External power supply + - Alarm Relay (5A) can be programmed to follow the BELL output or the Global PGM. - + Any device such as a strobe light or siren Keypad and Keypad Zone Connections To connect the keypads to the control panel, remove the back cover and wire the GRN, YEL, RED, and BLK terminals of each keypad to the corresponding terminals on the control panel as shown in “Spectra 1738 PCB Layout” on page 39 or “Spectra 1728 PCB Layout” on page 38. There is no limit to the number of keypads that can be connected to the control panel so long as the current consumption does not surpass 700mA. Each keypad has one zone input terminal, allowing you to connect one motion detector or door contact directly to a keypad. For example, a door contact located at the entry point of an establishment can be wired directly to the input terminal of the entry point keypad instead of wiring the door contact all the way to the control panel. The keypad can then communicate the status of the zone to the control panel. A maximum of two keypad zones can be used with each control panel. After connecting the device, the zone's parameters must be defined. For details on zone recognition and zone programming refer to page 4. For details on Keypad Tamper Supervision or Configuring the LED Keypads, please see the Spectra 1728 & 1738 Reference and Installation Manual. If you do not use the keypad zone, do not connect a jumper across the “ZN” and “-” terminals; leave the zone open. For proper operation of the keypad zones whether they are used or not, always enable the Keypad Zone Sending option on all LCD keypads. Spectra 1728 & 1738 - 37 - Programming Guide Spectra 1728 PCB Layout Service Keypad Reset Jumper Paradox Memory Key Four pin connector can be used for quick installation of a Spectra keypad or Expansion Module. Status LED Flash once every sec. = Normal operation Toggle ON 1sec / OFF 1sec = Trouble in the system Always ON = Panel is using phone line Fast flash 4sec. after power up = Installer Lock enabled 12Vdc 7Ah/4Ah Caution: Disconnect battery before replacing the fuse. Warning: Disconnect telephone line before servicing. See “Connecting Fire Circuits, Keyswitches and PGMs” on page 37. Refer to “Single Zone Inputs” on page 36. Cold water pipe grounding Refer to the Transformer Requirements table below. AWG#14 single conductor solid copper wire Ground clamp Warning: Improper connection may result in damage to the system. BELL OUTPUT Will shut down if current exceeds 3A. To provide maximum lightning protection we strongly recommend having separate earth connections for the dialer and zone ground terminals. To metallic enclosure SPECTRA KEYPADS • The maximum number of keypads per installation is dependent on the auxiliary output, which is not to exceed 700mA. • For the keypad’s zone, EOL and tamper configurations, refer to page 3. • Warning: Do not connect keypads more than 76m (250 ft) from the control panel. AUX POWER Refer to transformer requirements below for Aux. Power Output. To connect additional wiring to auxiliary power, use the red (+) and black (-) keypad connectors. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. A Door Contact or any other detection device can be connected to the Keypad Zone. For UL Listed warnings, refer to the UL and cUL Warnings section in the Spectra Reference & Installation Manual. Transformer Requirements Table Transformer: Spectra DC Power Supply rated at: Auxiliary Supply can provide a maximum of: Acceptable Battery Charge Currents (section [127] option [5]) * Not verified by UL. Spectra 1728 & 1738 - 38 Programming Guide Amseco XP-1620 16VAC 20VA* 1.2A typ: 600mA, max: 700mA 350mA Recommend: 16VAC 40VA UL: Basler BE156240CAA007 1.5A typ: 600mA, max: 700mA 350mA/700mA Spectra 1738 PCB Layout Reset Jumper Paradox Memory Key Status LED Flash once every sec: Normal Operation Toggle ON 1 sec /OFF 1 sec: Trouble in the system Always ON: Panel is using phone line Fast flash 4 sec after power up: Installer Lock enabled Warning: Disconnect telephone line before servicing Caution: Disconnect battery before replacing the fuse. UL/cUL 12Vdc / 4Ah or 7Ah Service Keypad Four pin connector can be used for quick installation of a Spectra keypad or expansion module. Refer to Transformer Requirements Table below. To connect the 5A alarm relay and the UL/cUL PGMs, refer to “Alarm Wheelock 46T-12 Relay (1738 only)” on page 37. BELL OUTPUT Will shut down if current exceeds 3A. Refer to “Single Zone Inputs” or “Double Zone Inputs (with ATZ option only)” on page 36 AWG#14 single conductor solid copper wire Ground clamp Cold water pipe grounding To metallic enclosure To provide maximum lightning protection, we strongly recommend having separate earth connections for the dialer and zone ground terminals. AUX POWER Refer to transformer requirements in the table below for AUX Power Output. Auxiliary power will shut down if current exceeds 1.1A. If the auxiliary output is overloaded and is shut down, you must disconnect all loads from the output for at least 10 seconds before reconnecting any load back to the auxiliary output. SPECTRA KEYPADS • The maximum number of keypads per installation is dependent on the auxiliary output, which is not to exceed 700 mA. • For the keypad’s zone, EOL and tamper configurations, refer to page 3. • Warning: Do not connect keypads more than 76m (250ft) from the control panel. Warning: Improper connection may result in damage to the system. A Door Contact or any other detection device can be connected to the Keypad Zone. For UL Listed warnings, refer to the UL and cUL Warnings section in the Spectra Reference & Installation Manual. Transformer Requirements Table Transformer: Amseco XP-1620 16VAC, 20VA* Spectra DC Power Supply rated at: 1.2A Auxiliary Supply can provide a maximum of: typ: 600mA, max: 700mA Acceptable Battery Charge Currents (section [127] option [5]) 350mA Rec: 16.5VAC 40VA UL: Basler BE156240CAA007 1.5A typ: 600mA, max: 700 mA 350mA/700mA * Not verified by UL. Spectra 1728 & 1738 - 39 Programming Guide ATZ Wiring Options (V2.4 or higher) A A - Control panel terminals B B - Detector 1 terminals C - Detector 2 terminals C Use a 2.2 k resistor for the ATZ zone input. Use a 1k resistor for the zone input. Warranty Paradox Security Systems Ltd. (“Seller”) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product’s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller’s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. © 2002-2005 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 5287111, 5119069, 5077549, 5920259 and 5886632. Canadian and international patents may also apply. Spectra, Digiplex and Magellan are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. For technical support in Canada or the U.S., call 1-800-791-1919 for English or 1-866-912-0600 for French, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.ca. 780 Industriel Blvd., Saint-Eustache (Quebec) J7R 5V3 CANADA Tel.: (450) 491-7444 Fax: (450) 491-2313 www.paradox.ca PRINTED IN CANADA - 07/2005 17X8-EP17